KGS Home Page Well Data base Specific Well--15-191-22591

General Well Data
Oil and Gas Index Page

Viewing General Well Data View Engineering Data

API: 15-191-22591
KID: 1043234370
Lease: WELLINGTON KGS
Well: 1-32
Original operator: BEREXCO LLC
Current operator: BEREXCO LLC
Field: Wellington
Location: T31S R1W, Sec. 32
NE SW NE NE
955 South, 877 West, from NE corner
NAD27 Longitude: -97.442414
NAD27 Latitude: 37.315444
NAD83 Longitude: -97.4427374
NAD83 Latitude: 37.3154639
Lat-long from GPS
County: Sumner
Permit Date: Dec-15-2010
Spud Date: Dec-29-2010
Completion Date: Aug-24-2011
Plugging Date:
Well Type: OTHER
(STRAT)
Status: Inactive Well
Total Depth: 5240
Elevation: 1272 KB
Producing Formation: ARBUCKLE
IP Oil (bbl):
IP Water (bbl):
IP GAS (MCF):
KCC Permit No.:
Lat Long added from legal survey on intent. (DLS-DRL 1-10-2011)
View well on interactive map
View well in the Walter’s Digital Library (WDL login required)

ACO-1 and Driller's Logs

PDF files from the KGS
Documents from the KCC
For information on software to view and use
the files we distribute on our web pages,
please view our File Format Tools page.

Wireline Log Header Data

Logger: Halliburton
Tool: Compensated Spectral Natural Gamma Ray
Operator on log BEREXCO LLC
Top: 607; Bottom: 5240
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Logger: Halliburton
Tool: Compensated Spectral Natural Gamma Ray
Operator on log BEREXCO LLC
Top: 607; Bottom: 5240
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Logger: Halliburton
Tool: AHV Calculation for 5.5 Casing
Operator on log BEREXCO LLC
Top: 607; Bottom: 5231
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Logger: Geologist's Report
Tool: Mud Log
Operator on log BEREXCO LLC
Top: 2200; Bottom: 5239
Log Date: Dec-29-2010
BHT: F
Gamma Ray:
Spontaneous Potential:
Holdings at: Lawrence
Logger: Halliburton
Tool: Array Compensated True Resistivity
Operator on log BEREXCO LLC
Top: 607; Bottom: 5231
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential: Y
Holdings at: Lawrence
Logger: Halliburton
Tool: Microlog
Operator on log BEREXCO LLC
Top: 607; Bottom: 5240
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Logger: Halliburton
Tool: Borehole Temperature
Operator on log BEREXCO LLC
Top: 607; Bottom: 5170
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
 
Logger: Halliburton
Tool: Extended Range Micro Imager Correlation Plot
Operator on log BEREXCO LLC
Top: 607; Bottom: 5231
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Original log is in color.
 
Logger: Halliburton
Tool: Magnetic Resonance Imaging Log
Operator on log BEREXCO LLC
Top: 2250; Bottom: 5240
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential: Y
Holdings at: Lawrence
Original log is in color.
 
Logger: Halliburton
Tool: Extended Range Micro Imager Correlation Plot
Operator on log BEREXCO LLC
Top: 607; Bottom: 5231
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Original log is in color.
 
Logger: Halliburton
Tool: Composite Plot
Operator on log BEREXCO LLC
Top: 2241; Bottom: 5239
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Original log is in color.
Logger: Halliburton
Tool: WaveSonic Slowness Porosity Log
Operator on log BEREXCO LLC
Top: 460; Bottom: 5244
Log Date: Feb-22-2011
BHT: F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Original log is in color.
 
Logger: Log-Tech
Tool: Borehole Compensated Sonic
Operator on log Berexco, LLC
Top: 0; Bottom: 608
Log Date: Jan-03-2011
BHT: 84F
Gamma Ray: Y
Spontaneous Potential:
Log via KCC Electronic Submittal.
Logger: Halliburton
Tool: Spectral Density Dual Spaced Neutron
Operator on log BEREXCO LLC
Top: 607; Bottom: 5217
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray:
Spontaneous Potential:
Holdings at: Lawrence
Logger: Halliburton
Tool: Spectral Density Dual Spaced Neutron
Operator on log BEREXCO LLC
Top: 607; Bottom: 4550
Log Date: Jan-22-2011
BHT: 115F
Gamma Ray:
Spontaneous Potential:
Holdings at: Lawrence
Logger: Halliburton
Tool: Extended Range Micro Imager
Operator on log BEREXCO LLC
Top: 607; Bottom: 5240
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Logger: Halliburton
Tool: Extended Range Micro Imager Correlation Plot
Operator on log BEREXCO LLC
Top: 2241; Bottom: 5239
Log Date: Mar-31-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Original log is in color.
Logger: Halliburton
Tool: Microlog
Operator on log BEREXCO LLC
Top: 607; Bottom: 4550
Log Date: Jan-22-2011
BHT: 115F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Logger: Halliburton
Tool: Array Compensated Resistivity
Operator on log BEREXCO LLC
Top: 607; Bottom: 4564
Log Date: Jan-22-2011
BHT: 115F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Logger: Halliburton
Tool: Gamma Elements and Minerals Tool monitor Log
Operator on log BEREXCO LLC
Top: 607; Bottom: 5197
Log Date: Feb-09-2011
BHT: 125F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
For information on software to view and use the files we distribute
on our web pages, please view our File Format Tools page.

Digital Wireline Log (LAS File) available

(Right click and "Save File As" to download)
File 1
(log courtesy Dan Suchy (dsuchy@kgs.ku.edu))
Starting depth: 580
Stopping depth: 5247.5
Download
this log
View this
log header
File 2
(log courtesy CO2 Project)
Starting depth: 0
Stopping depth: 5248
Download
this log
View this
log header
File 3
(log courtesy KCC)
Starting depth: -5
Stopping depth: 620
Download
this log
View this
log header
For information on software to view and use the files we distribute on our web pages, please view our File Format Tools page.

LAS 3.0 Files from CO2 Project available

LAS3 File Summary Web Page

Cuttings Data

Box Number: E2642
Starting Depth: 613
Ending Depth: 1550
Box Number: E2643
Starting Depth: 1550
Ending Depth: 2500
Skips: 2380-2390
Box Number: E2644
Starting Depth: 2500
Ending Depth: 3450
Skips: 3360-3400
Box Number: E2645
Starting Depth: 3450
Ending Depth: 4370
Skips: 3599-3600;3870-3930;3988-4019;4120-4130;4250-4260
Box Number: E2646
Starting Depth: 4370
Ending Depth: 4960
Skips: 4620-4625
Box Number: E2647
Starting Depth: 4960
Ending Depth: 5240
Skips: 5120-5125;5140-5170;5175-5240

Core Library Listings

Barcode Facility Aisle Column Row Top Bottom Core Type Status Comments Tops
220656 North Lawrence facility A A 5 613 1200 Cuttings On Shelf Box 1 of 9  
220657 North Lawrence facility A A 5 1200 1870 Cuttings On Shelf Box 2 of 9  
220658 North Lawrence facility A A 5 1870 2550 Cuttings On Shelf Box 3 of 9 Heebner Shale at 2406
220659 North Lawrence facility A A 5 2550 3210 Cuttings On Shelf Box 4 of 9 Iatan at 2680
220660 Moore Hall facility A B 2 3210 3800 Cuttings Unavailable Not able to locate 08/2022 - OJ Pawnee at 3450
223130 Moore Hall facility A A 2 3540 3549 Slabbed On Shelf    
222610 Moore Hall facility A B 7 3540 3543 Butt On Shelf start of core 1; 21 boxes  
410120 CHECKOUT facility XXX XXX XXX 3541.6 4775.15 Thin Section Checked Out Thin Sections depths at: 3541.6, 3541.75, 4273.15, 4275.35, 4434, 4484.2, 4775, 4775.15 Mississippi at 3658
403506 Moore Hall facility A A 5 3541.9 3762.6 Core Samples On Shelf End Trims at depth: 3541.90, 3547.25, 3554.60, 3592.90, 3600.25, 3608.00, 3628.15, 3638.30, 3661.30, 3665.80, 3670.60, 3678.90, 3681.95, 3684.20, 3686.90, 3689.90, 3693.75, 3699.75, 3705.75, 3709.10, 3714.10, 3717.90, 3722.40, 3728.40, 3731.85, 3733.70, 3739.80, 3746.90, 3754.70, 3762.60. Mississippi at 3658
222611 Moore Hall facility A B 7 3543 3546 Butt On Shelf    
222612 Moore Hall facility A B 7 3546 3549 Butt On Shelf    
511349 Moore Hall facility A A 5 3546 5160.15 Plug On Shelf Plugs at depths: 4732.6, 5160.15, 4815.9, 4732.8, 4746, 4755.65, 4767, 4365.65, 4579.9, 4579.8, 4755.8, 3663.9, 3668, 3985, 3960, 3735, 3546, 3983. added sample bag at depth 5177.0 from Lynn Watney collection. Mississippi at 3658
222613 Moore Hall facility A B 7 3549 3552 Butt On Shelf    
223131 Moore Hall facility A A 2 3549 3558 Slabbed On Shelf    
222614 Moore Hall facility A B 7 3552 3555 Butt On Shelf    
222615 Moore Hall facility A B 7 3555 3558 Butt On Shelf    
223132 Moore Hall facility A A 2 3558 3567 Slabbed On Shelf    
222616 Moore Hall facility A B 7 3558 3561 Butt On Shelf    
222617 Moore Hall facility A B 7 3561 3564 Butt On Shelf    
222618 Moore Hall facility A B 7 3564 3567 Butt On Shelf    
223133 Moore Hall facility A A 2 3567 3576 Slabbed On Shelf    
222619 Moore Hall facility A B 7 3567 3570 Butt On Shelf    
222620 Moore Hall facility A B 7 3570 3572.5 Butt On Shelf    
222621 Moore Hall facility A B 7 3572.5 3575 Butt On Shelf 35  
222622 Moore Hall facility A B 7 3575 3578 Butt On Shelf    
223134 Moore Hall facility A A 2 3576 3585 Slabbed On Shelf    
222623 Moore Hall facility A B 7 3578 3581 Butt On Shelf    
222624 Moore Hall facility A B 7 3581 3584 Butt On Shelf    
222625 Moore Hall facility A B 7 3584 3587 Butt On Shelf    
223135 Moore Hall facility A A 2 3585 3594 Slabbed On Shelf    
222626 Moore Hall facility A B 7 3587 3590 Butt On Shelf    
222627 Moore Hall facility A B 7 3590 3593 Butt On Shelf    
222628 Moore Hall facility A B 7 3593 3596 Butt On Shelf    
223136 Moore Hall facility A A 2 3594 3600 Slabbed On Shelf    
222629 Moore Hall facility A B 7 3596 3599 Butt On Shelf    
222630 Moore Hall facility A B 7 3599 3600 Butt On Shelf    
222631 Moore Hall facility A B 7 3600 3603 Butt On Shelf    
223137 Moore Hall facility A A 2 3600 3609 Slabbed On Shelf    
222632 Moore Hall facility A B 7 3603 3606 Butt On Shelf    
222633 Moore Hall facility A B 7 3606 3609 Butt On Shelf    
223138 Moore Hall facility A A 2 3609 3618 Slabbed On Shelf    
222634 Moore Hall facility A B 7 3609 3612 Butt On Shelf    
222635 Moore Hall facility A B 7 3612 3615 Butt On Shelf    
222636 Moore Hall facility A B 7 3615 3618 Butt On Shelf    
223139 Moore Hall facility A A 2 3618 3627 Slabbed On Shelf    
222637 Moore Hall facility A B 7 3618 3621 Butt On Shelf    
222638 Moore Hall facility A B 7 3621 3624 Butt On Shelf    
222639 Moore Hall facility A B 7 3624 3627 Butt On Shelf    
223140 Moore Hall facility A A 2 3627 3636 Slabbed On Shelf    
222640 Moore Hall facility A B 7 3627 3630 Butt On Shelf    
222641 Moore Hall facility A B 7 3630 3633 Butt On Shelf    
222642 Moore Hall facility A B 7 3633 3636 Butt On Shelf    
223141 Moore Hall facility A A 2 3636 3645 Slabbed On Shelf    
222643 Moore Hall facility A B 7 3636 3639 Butt On Shelf    
222644 Moore Hall facility A B 7 3639 3642 Butt On Shelf    
222645 Moore Hall facility A B 7 3642 3645 Butt On Shelf    
222646 Moore Hall facility A B 7 3645 3648 Butt On Shelf    
223142 Moore Hall facility A A 2 3645 3654 Slabbed On Shelf    
222647 Moore Hall facility A B 7 3648 3651 Butt On Shelf    
222648 Moore Hall facility A B 7 3651 3654 Butt On Shelf    
223143 Moore Hall facility A A 2 3654 3661 Slabbed Checked In   Mississippi at 3658
222649 Moore Hall facility A B 7 3654 3657 Butt On Shelf    
222650 Moore Hall facility A B 7 3657 3660 Butt On Shelf   Mississippi at 3658
222651 Moore Hall facility A B 7 3660 3661 Butt On Shelf    
222652 Moore Hall facility A B 7 3661 3662 Butt On Shelf start of core 3; 12 boxes  
223144 Moore Hall facility A A 2 3661 3669 Slabbed Checked In    
222653 Moore Hall facility A B 7 3662 3665 Butt On Shelf    
222654 Moore Hall facility A B 7 3665 3668 Butt On Shelf    
222655 Moore Hall facility A B 7 3668 3671 Butt On Shelf    
223145 Moore Hall facility A A 2 3669 3678 Slabbed Checked In    
510019 Moore Hall facility B C 4 3671 4027 Core Samples On Shelf Samples at depths: 3671, 3680, 3689, 3694, 3703, 3712, 3721, 3725, 3736, 3737, 3748, 3753, 3763, 3772, 3781, 3790, 3799, 3807, 3814, 3823, 3827, 3830, 3841, 3871, 3872, 3883, 3892, 3910, 3914, 3939, 3941, 3952, 3958, 3962, 3982, 3988, 3995, 4003, 4008, 4009, 4015, 4016, 4022, 4027  
222656 Moore Hall facility A B 7 3671 3674 Butt On Shelf    
410123 CHECKOUT facility XXX XXX XXX 3671.8 3876.5 Thin Section Checked Out Thin Sections at: 3671.8, 3689, 3694.6, 3712.5, 3724.5, 3736, 3748.9, 3753.8, 3772.3, 3785.4, 3790, 3794.5, 3797.3, 3823.3, 3828, 3841.5, 3851.75, 3857.5, 3867, 3872.75, 3876.5  
410121 Moore Hall facility B C 4 3671.8 4064 Core Samples On Shelf Billets at depths: 3671.8, 3680.7, 3689, 3694.6, 3702.5, 3712.5, 3724.5, 3736, 3748.9, 3753.8, 3772.3, 3794.5, 3797, 3797.3, 3807.5, 3823.3, 3828, 3841.5, 3851.75, 3857.5, 3867, 3883.5, 3915, 3939.5, 3953, 3967.4, 3982.4, 3989.5, 3996.2, 4003.7, 4009.2, 4016.4, 4022, 4029.8, 445.9, 4049.4, 4052.9, 4055, 4058, 4061.5, 4064  
222657 Moore Hall facility A B 7 3674 3677 Butt On Shelf    
222658 Moore Hall facility A B 7 3677 3680 Butt On Shelf    
223146 Moore Hall facility A A 2 3678 3687 Slabbed Checked In    
222659 Moore Hall facility A B 7 3680 3683 Butt On Shelf    
222660 Moore Hall facility A B 7 3683 3686 Butt On Shelf    
222661 Moore Hall facility A B 7 3686 3689 Butt On Shelf    
223147 Moore Hall facility A A 2 3687 3692 Slabbed Checked In    
222662 Moore Hall facility A B 7 3689 3691.5 Butt On Shelf    
222663 Moore Hall facility A B 7 3691.5 3692 Butt On Shelf    
223148 Moore Hall facility A A 2 3692 3701 Slabbed Checked In    
222664 Moore Hall facility A B 7 3692 3695 Butt On Shelf start of core 4; 21 boxes  
222665 Moore Hall facility A B 7 3695 3698 Butt On Shelf    
222666 Moore Hall facility A B 7 3698 3701 Butt On Shelf    
223149 Moore Hall facility A A 2 3701 3710 Slabbed Checked In    
222667 Moore Hall facility A B 7 3701 3704 Butt On Shelf    
222668 Moore Hall facility A B 7 3704 3707 Butt On Shelf    
222669 Moore Hall facility A B 7 3707 3710 Butt On Shelf    
223150 Moore Hall facility A A 2 3710 3719 Slabbed On Shelf    
222670 Moore Hall facility A B 7 3710 3713 Butt On Shelf    
222671 Moore Hall facility A B 7 3713 3716 Butt On Shelf    
222672 Moore Hall facility A B 7 3716 3719 Butt On Shelf    
222673 Moore Hall facility A B 7 3719 3721 Butt On Shelf    
223151 Moore Hall facility A A 2 3719 3728 Slabbed On Shelf    
222674 Moore Hall facility A B 7 3721 3724 Butt On Shelf    
222675 Moore Hall facility A B 7 3724 3727 Butt On Shelf    
222676 Moore Hall facility A B 7 3727 3730 Butt On Shelf    
223152 Moore Hall facility A A 2 3728 3737 Slabbed On Shelf    
222677 Moore Hall facility A B 7 3730 3733 Butt On Shelf    
222678 Moore Hall facility A B 7 3733 3736 Butt On Shelf    
222679 Moore Hall facility A B 7 3736 3739 Butt On Shelf    
223153 Moore Hall facility A A 2 3737 3746 Slabbed On Shelf    
222680 Moore Hall facility A B 7 3739 3742 Butt On Shelf    
222681 Moore Hall facility A B 7 3742 3745 Butt On Shelf    
222682 Moore Hall facility A B 7 3745 3748 Butt On Shelf    
223154 Moore Hall facility A A 2 3746 3752 Slabbed On Shelf    
222683 Moore Hall facility A B 7 3748 3751 Butt On Shelf    
222684 Moore Hall facility A B 7 3751 3752 Butt On Shelf    
222685 Moore Hall facility A B 6 3752 3755 Butt On Shelf start of core 5; 21 boxes  
223155 Moore Hall facility A A 2 3752 3761 Slabbed On Shelf    
222686 Moore Hall facility A B 6 3755 3758 Butt On Shelf    
222687 Moore Hall facility A B 6 3758 3761 Butt On Shelf    
222688 Moore Hall facility A B 6 3761 3764 Butt On Shelf    
223156 Moore Hall facility A A 2 3761 3770 Slabbed On Shelf    
222689 Moore Hall facility A B 6 3764 3767 Butt On Shelf    
222690 Moore Hall facility A B 6 3767 3770 Butt On Shelf    
403507 Moore Hall facility A A 5 3767.7 3991.9 Core Samples On Shelf End Trims at depths: 3767.70, 3777.50, 3789.15, 3795.30, 3804.90, 3832.15, 3837.10, 3856.10, 3861.20, 3867.90, 3870.60, 3876.90, 3884.60, 3893.90, 3896.20, 3902.80, 3912.90, 3915.90, 3922.40, 3925.90, 3930.10, 3937.45, 3940.20, 3945.80, 3954.90, 3967.80, 3969.90, 3979.30, 3988.20, 3991.90.  
223157 Moore Hall facility A A 2 3770 3779 Slabbed On Shelf    
222691 Moore Hall facility A B 6 3770 3773 Butt On Shelf    
222692 Moore Hall facility A B 6 3773 3776 Butt On Shelf    
222693 Moore Hall facility A B 6 3776 3779 Butt On Shelf    
223158 Moore Hall facility A A 2 3779 3788 Slabbed On Shelf    
222694 Moore Hall facility A B 6 3779 3782 Butt On Shelf    
222695 Moore Hall facility A B 6 3782 3785 Butt On Shelf    
222696 Moore Hall facility A B 6 3785 3788 Butt On Shelf    
222697 Moore Hall facility A B 6 3788 3791 Butt On Shelf    
223159 Moore Hall facility A A 2 3788 3797 Slabbed On Shelf    
222698 Moore Hall facility A B 6 3791 3794 Butt On Shelf    
222699 Moore Hall facility A B 6 3794 3796.5 Butt On Shelf    
510018 Moore Hall facility B C 4 3794 4095 Core Samples On Shelf Samples at depths: 3794, 3797, 3913, 3926, 3967, 3985, 3989, 3996, 4002, 4026, 4028, 4045, 4048, 4049, 4050, 4051a, 4051b, 4053, 4054, 4055, 4056, 4057, 4058, 4060, 4061, 4062, 4064, 4065, 4095  
222700 Moore Hall facility A B 6 3796.5 3799.5 Butt On Shelf    
223160 Moore Hall facility A A 2 3797 3806 Slabbed On Shelf    
222701 Moore Hall facility A B 6 3799.5 3802.5 Butt On Shelf    
220661 Moore Hall facility A B 2 3800 4300 Cuttings Unavailable Not able to locate 08/2022 - OJ Simpson Shale at 4100
222702 Moore Hall facility A B 6 3802.5 3805 Butt On Shelf    
222703 Moore Hall facility A B 6 3805 3808 Butt On Shelf    
223161 Moore Hall facility A A 2 3806 3812 Slabbed On Shelf    
222704 Moore Hall facility A B 6 3808 3811.5 Butt On Shelf    
222705 Moore Hall facility A B 6 3811 3814 Butt On Shelf    
223162 Moore Hall facility A A 2 3812 3821 Slabbed On Shelf    
222706 Moore Hall facility A B 6 3814 3818 Butt On Shelf    
222707 Moore Hall facility A B 6 3818 3821 Butt On Shelf    
223163 Moore Hall facility A A 2 3821 3830 Slabbed On Shelf    
222708 Moore Hall facility A B 6 3821 3824 Butt On Shelf    
410115 Moore Hall facility B C 4 3823.3 3797.3 Cuttings On Shelf Cuttings at depths: 3680.7, 3689, 3694.6, 3702.5, 3736, 3748.9, 3753.8, 3772.3, 3794.5, 3797.3, 3823.3, 3828, 3841.5, 3851.75, 3939.5, 3953, 3967.4  
222709 Moore Hall facility A B 6 3824 3827 Butt On Shelf    
222710 Moore Hall facility A B 6 3827 3830 Butt On Shelf    
222711 Moore Hall facility A B 6 3830 3833 Butt On Shelf    
223164 Moore Hall facility A A 2 3830 3839 Slabbed On Shelf    
222712 Moore Hall facility A B 6 3833 3836 Butt On Shelf    
222713 Moore Hall facility A B 6 3836 3839 Butt On Shelf    
223165 Moore Hall facility A A 2 3839 3848 Slabbed On Shelf    
222714 Moore Hall facility A B 6 3839 3842 Butt On Shelf    
222715 Moore Hall facility A B 6 3842 3845 Butt On Shelf    
222716 Moore Hall facility A B 6 3845 3845 Butt On Shelf    
222717 Moore Hall facility A B 6 3845 3848 Butt On Shelf    
223166 Moore Hall facility A A 2 3848 3857 Slabbed On Shelf    
222718 Moore Hall facility A B 6 3848 3851 Butt On Shelf    
222719 Moore Hall facility A B 6 3851 3854 Butt On Shelf    
222720 Moore Hall facility A B 6 3854 3857 Butt On Shelf    
222721 Moore Hall facility A B 6 3857 3860 Butt On Shelf    
223167 Moore Hall facility A A 2 3857 3866 Slabbed On Shelf    
222722 Moore Hall facility A B 6 3860 3863 Butt On Shelf    
222723 Moore Hall facility A B 6 3863 3866 Butt On Shelf    
222724 Moore Hall facility A B 6 3866 3869 Butt On Shelf    
223168 Moore Hall facility A A 2 3866 3872 Slabbed On Shelf    
222725 Moore Hall facility A B 6 3869 3871 Butt On Shelf    
222726 Moore Hall facility A B 6 3871 3872 Butt On Shelf    
223169 Moore Hall facility A A 2 3872 3881 Slabbed On Shelf    
222727 Moore Hall facility A B 6 3872 3875 Butt On Shelf    
222728 Moore Hall facility A B 6 3875 3878 Butt On Shelf    
222729 Moore Hall facility A B 6 3878 3881 Butt On Shelf    
223170 Moore Hall facility A A 2 3881 3890 Slabbed On Shelf    
222730 Moore Hall facility A B 6 3881 3884 Butt On Shelf    
410122 CHECKOUT facility XXX XXX XXX 3883.5 4064 Thin Section Checked Out Thin Sections at: 3883.5, 3892.5, 3910.25, 3915, 3939.5, 3953, 3967.4, 3982.4, 3989.5, 3996.2, 4003.7, 4009.2, 4016.4, 4022, 4026.4, 4029.8, 4045.9, 4049.4, 4052.9, 4055, 4058, 4061.4, 4064  
222731 Moore Hall facility A B 6 3884 3887 Butt On Shelf    
222732 Moore Hall facility A B 6 3887 3890 Butt On Shelf    
223171 Moore Hall facility A A 2 3890 3899 Slabbed On Shelf    
222733 Moore Hall facility A B 6 3890 3892 Butt On Shelf    
222734 Moore Hall facility A B 6 3892 3895 Butt On Shelf    
222735 Moore Hall facility A B 6 3895 3898 Butt On Shelf    
222736 Moore Hall facility A B 6 3898 3900 Butt On Shelf    
223172 Moore Hall facility A A 2 3899 3908 Slabbed On Shelf    
222737 Moore Hall facility A B 6 3900 3903 Butt On Shelf    
222738 Moore Hall facility A B 6 3903 3906 Butt On Shelf    
222739 Moore Hall facility A B 6 3906 3909 Butt On Shelf    
223173 Moore Hall facility A A 2 3908 3917 Slabbed On Shelf    
222740 Moore Hall facility A B 6 3909 3912 Butt On Shelf    
222741 Moore Hall facility A B 6 3912 3915 Butt On Shelf    
222742 Moore Hall facility A B 6 3915 3918 Butt On Shelf    
223174 Moore Hall facility A A 2 3917 3926 Slabbed On Shelf    
222743 Moore Hall facility A B 6 3918 3921 Butt On Shelf    
222744 Moore Hall facility A B 6 3921 3924 Butt On Shelf    
222745 Moore Hall facility A B 6 3924 3927 Butt On Shelf    
223175 Moore Hall facility A A 2 3926 3929 Slabbed On Shelf    
222746 Moore Hall facility A B 6 3927 3929 Butt On Shelf    
223176 Moore Hall facility A A 2 3929 3938 Slabbed On Shelf    
222747 Moore Hall facility A B 6 3929 3932 Butt On Shelf    
222748 Moore Hall facility A B 6 3932 3935 Butt On Shelf    
222749 Moore Hall facility A B 6 3935 3938 Butt On Shelf    
223177 Moore Hall facility A A 2 3938 3947 Slabbed On Shelf    
222750 Moore Hall facility A B 6 3938 3941 Butt On Shelf    
222751 Moore Hall facility A B 6 3941 3944 Butt On Shelf    
222752 Moore Hall facility A B 6 3944 3947 Butt On Shelf    
222753 Moore Hall facility A B 6 3947 3950 Butt On Shelf    
223178 Moore Hall facility A A 2 3947 3956 Slabbed On Shelf    
222754 Moore Hall facility A B 6 3950 3953 Butt On Shelf    
222755 Moore Hall facility A B 6 3953 3956 Butt On Shelf    
222756 Moore Hall facility A B 6 3956 3959 Butt On Shelf    
223179 Moore Hall facility A A 2 3956 3965 Slabbed On Shelf    
222757 Moore Hall facility A B 6 3959 3959 Butt On Shelf    
222758 Moore Hall facility A B 6 3959 3962 Butt On Shelf    
222759 Moore Hall facility A B 6 3962 3965 Butt On Shelf    
222760 Moore Hall facility A B 6 3965 3968 Butt On Shelf    
223180 Moore Hall facility A A 2 3965 3974 Slabbed On Shelf    
222761 Moore Hall facility A B 6 3968 3971 Butt On Shelf    
222762 Moore Hall facility A B 6 3971 3974 Butt On Shelf    
223181 Moore Hall facility A A 2 3974 3983 Slabbed On Shelf    
222763 Moore Hall facility A B 6 3974 3977 Butt On Shelf    
222764 Moore Hall facility A B 6 3977 3980 Butt On Shelf    
222765 Moore Hall facility A B 6 3980 3983 Butt On Shelf    
223182 Moore Hall facility A A 2 3983 3990 Slabbed On Shelf    
222766 Moore Hall facility A B 6 3983 3986 Butt On Shelf    
222767 Moore Hall facility A B 6 3986 3989 Butt On Shelf    
222768 Moore Hall facility A B 6 3989 3990 Butt On Shelf    
222769 Moore Hall facility A B 5 3990 3993 Butt On Shelf    
223183 Moore Hall facility A A 2 3990 3999 Slabbed On Shelf    
222770 Moore Hall facility A B 5 3993 3996 Butt On Shelf    
222771 Moore Hall facility A B 5 3996 3999 Butt On Shelf    
223184 Moore Hall facility A A 2 3999 4008 Slabbed On Shelf    
222772 Moore Hall facility A B 5 3999 4002 Butt On Shelf    
403508 Moore Hall facility A A 5 4001.1 4195.1 Core Samples On Shelf End trims at depths: 4001.10, 4009.15, 4013.00, 4026.70, 4029.90, 4035.90, 4052.30, 4065.20, 4066.90, 4072.90, 4077.20, 4083.63, 4094.10, 4097.30, 4111.60, 4119.10, 4121.10, 4123.50, 4135.85, 4152.40, 4157.20, 4159.70, 4160.50, 4174.55, 4176.10, 4178.90, 4184.75, 4187.20, 4193.30, 4195.10 Simpson Shale at 4100
222773 Moore Hall facility A B 5 4002 4005 Butt On Shelf    
222774 Moore Hall facility A B 5 4005 4008 Butt On Shelf    
223185 Moore Hall facility A A 2 4008 4017 Slabbed On Shelf    
222775 Moore Hall facility A B 5 4008 4011 Butt On Shelf    
222776 Moore Hall facility A B 5 4011 4014 Butt On Shelf    
222777 Moore Hall facility A B 5 4014 4017 Butt On Shelf    
222778 Moore Hall facility A B 5 4017 4020 Butt On Shelf    
223186 Moore Hall facility A A 2 4017 4020 Slabbed On Shelf    
223187 Moore Hall facility A A 2 4020 4029 Slabbed On Shelf    
222780 Moore Hall facility A B 5 4020 4024 Butt On Shelf    
222779 Moore Hall facility A B 5 4020 4020 Butt On Shelf    
222781 Moore Hall facility A B 5 4024 4026 Butt On Shelf    
222782 Moore Hall facility A B 5 4026 4029 Butt On Shelf    
223188 Moore Hall facility A A 2 4029 4038 Slabbed On Shelf    
222783 Moore Hall facility A B 5 4029 4032 Butt On Shelf    
222784 Moore Hall facility A B 5 4032 4035 Butt On Shelf    
222785 Moore Hall facility A B 5 4035 4038 Butt On Shelf    
222786 Moore Hall facility A B 5 4038 4041 Butt On Shelf    
223189 Moore Hall facility A A 2 4038 4047 Slabbed On Shelf    
222787 Moore Hall facility A B 5 4041 4044 Butt On Shelf    
222788 Moore Hall facility A B 5 4044 4047 Butt On Shelf    
223190 Moore Hall facility A A 2 4047 4056 Slabbed On Shelf    
222789 Moore Hall facility A B 5 4047 4048 Butt On Shelf    
222790 Moore Hall facility A B 5 4048 4051 Butt On Shelf    
222791 Moore Hall facility A B 5 4051 4054 Butt On Shelf    
222792 Moore Hall facility A B 5 4054 4057 Butt On Shelf    
223191 Moore Hall facility A A 2 4056 4065 Slabbed On Shelf    
222793 Moore Hall facility A B 5 4057 4060 Butt On Shelf    
222794 Moore Hall facility A B 5 4060 4063 Butt On Shelf    
222795 Moore Hall facility A B 5 4063 4066 Butt Checked In    
223192 Moore Hall facility A A 2 4065 4074 Slabbed On Shelf    
222796 Moore Hall facility A B 5 4066 4069 Butt On Shelf    
222797 Moore Hall facility A B 5 4069 4072 Butt On Shelf    
222798 Moore Hall facility A B 5 4072 4075 Butt On Shelf    
223193 Moore Hall facility A A 2 4074 4079 Slabbed On Shelf    
222799 Moore Hall facility A B 5 4075 4078 Butt On Shelf    
222800 Moore Hall facility A B 5 4078 4080 Butt On Shelf    
223194 Moore Hall facility A A 2 4079 4088 Slabbed On Shelf    
222801 Moore Hall facility A B 5 4080 4082 Butt On Shelf    
222802 Moore Hall facility A B 5 4082 4085 Butt On Shelf    
222803 Moore Hall facility A B 5 4085 4088 Butt On Shelf    
222804 Moore Hall facility A B 5 4088 4091 Butt On Shelf    
223195 Moore Hall facility A A 6 4088 4097 Slabbed On Shelf    
222805 Moore Hall facility A B 5 4091 4094 Butt On Shelf    
222806 Moore Hall facility A B 5 4094 4097 Butt On Shelf    
222807 Moore Hall facility A B 5 4097 4100 Butt On Shelf    
223196 Moore Hall facility A A 6 4097 4106 Slabbed On Shelf   Simpson Shale at 4100
222808 Moore Hall facility A B 5 4100 4103 Butt On Shelf    
222809 Moore Hall facility A B 5 4103 4106 Butt On Shelf    
222810 Moore Hall facility A B 5 4106 4108 Butt On Shelf    
223197 Moore Hall facility A A 6 4106 4115 Slabbed On Shelf    
222811 Moore Hall facility A B 5 4108 4111 Butt On Shelf    
222812 Moore Hall facility A B 5 4111 4114 Butt On Shelf    
222813 Moore Hall facility A B 5 4114 4117 Butt On Shelf    
223198 Moore Hall facility A A 6 4115 4124 Slabbed On Shelf    
222814 Moore Hall facility A B 5 4117 4120 Butt On Shelf    
222815 Moore Hall facility A B 5 4120 4123 Butt On Shelf    
222816 Moore Hall facility A B 5 4123 4126 Butt On Shelf    
223199 Moore Hall facility A A 6 4124 4133 Slabbed On Shelf    
222817 Moore Hall facility A B 5 4126 4129 Butt On Shelf    
222818 Moore Hall facility A B 5 4129 4132 Butt On Shelf    
222819 Moore Hall facility A B 5 4132 4135 Butt On Shelf    
223200 Moore Hall facility A A 6 4133 4138 Slabbed On Shelf    
222820 Moore Hall facility A B 5 4135 4138 Butt On Shelf    
222821 Moore Hall facility A B 5 4138 4139 Butt On Shelf    
223201 Moore Hall facility A A 6 4138.8 4147 Slabbed On Shelf    
222822 Moore Hall facility A B 5 4139 4141 Butt On Shelf    
222823 Moore Hall facility A B 5 4141 4144 Butt On Shelf    
222824 Moore Hall facility A B 5 4144 4147 Butt On Shelf    
222825 Moore Hall facility A B 5 4147 4150 Butt On Shelf    
223202 Moore Hall facility A A 6 4147 4156 Slabbed On Shelf    
222826 Moore Hall facility A B 5 4150 4153 Butt On Shelf    
222827 Moore Hall facility A B 5 4153 4155 Butt On Shelf    
222828 Moore Hall facility A B 5 4155 4157 Butt On Shelf    
223203 Moore Hall facility A A 6 4156 4163.1 Slabbed On Shelf    
222829 Moore Hall facility A B 5 4157 4160 Butt On Shelf    
222830 Moore Hall facility A B 5 4160 4163 Butt On Shelf    
222831 Moore Hall facility A B 5 4163 4166 Butt On Shelf   Arbuckle at 4164
223204 Moore Hall facility A A 6 4163.1 4172 Slabbed Checked In   Arbuckle at 4164
222832 Moore Hall facility A B 5 4166 4169 Butt On Shelf    
222833 Moore Hall facility A B 5 4169 4172 Butt On Shelf    
222834 Moore Hall facility A B 5 4172 4175 Butt On Shelf    
223205 Moore Hall facility A A 6 4172 4181 Slabbed Checked In    
222835 Moore Hall facility A B 5 4175 4178 Butt On Shelf    
222836 Moore Hall facility A B 5 4178 4181 Butt On Shelf    
222837 Moore Hall facility A B 5 4181 4184 Butt On Shelf    
223206 Moore Hall facility A A 6 4181 4185.5 Slabbed Checked In    
222838 Moore Hall facility A B 5 4184 4186 Butt On Shelf    
223207 Moore Hall facility A A 6 4185.5 4194 Slabbed Checked In    
222839 Moore Hall facility A B 5 4186 4189 Butt On Shelf    
222840 Moore Hall facility A B 5 4189 4192 Butt On Shelf    
222841 Moore Hall facility A B 5 4192 4195 Butt On Shelf    
223208 Moore Hall facility A A 6 4194 4203 Slabbed Checked In    
222842 Moore Hall facility A B 5 4195 4198 Butt On Shelf    
222843 Moore Hall facility A B 5 4198 4201 Butt On Shelf    
222844 Moore Hall facility A B 5 4201 4204 Butt On Shelf    
403509 Moore Hall facility A A 5 4202.3 4465.75 Core Samples On Shelf End trims at depths: 4202.30, 4207.10, 4212.60, 4213.80, 4221.90, 4225.70, 4230.30, 4235.90, 4243.00, 4247.00, 4252.50, 4262.60, 4280.40, 4299.10, 4308.10, 4342.50, 4365.80, 4379.10, 4388.80, 4394.60, 4399.85, 4406.35, 4410.90, 4431.60, 4441.00, 4443.80, 4446.00, 4451.90, 4460.80, 4465.75  
223209 Moore Hall facility A A 6 4203 4212 Slabbed Checked In    
222845 Moore Hall facility A B 5 4204 4207 Butt On Shelf    
222846 Moore Hall facility A B 5 4207 4210 Butt On Shelf    
222847 Moore Hall facility A B 5 4210 4213 Butt On Shelf    
223210 Moore Hall facility A A 6 4212 4221 Slabbed Checked In    
222848 Moore Hall facility A B 5 4213 4214 Butt On Shelf    
222849 Moore Hall facility A B 5 4214 4217 Butt On Shelf    
222850 Moore Hall facility A B 5 4217 4220 Butt On Shelf    
222851 Moore Hall facility A B 5 4220 4223 Butt On Shelf    
223211 Moore Hall facility A A 6 4221 4230 Slabbed Checked In    
222852 Moore Hall facility A B 5 4223 4226 Butt On Shelf    
222853 Moore Hall facility A B 5 4226 4229 Butt On Shelf    
222854 Moore Hall facility A B 5 4229 4232 Butt On Shelf    
223212 Moore Hall facility A A 6 4230 4239 Slabbed Checked In    
222855 Moore Hall facility A B 5 4232 4235 Butt On Shelf    
222856 Moore Hall facility A B 5 4235 4238 Butt On Shelf    
222857 Moore Hall facility A B 5 4238 4241 Butt On Shelf    
223213 Moore Hall facility A A 6 4239 4244.8 Slabbed Checked In    
222858 Moore Hall facility A B 5 4241 4244 Butt On Shelf    
222859 Moore Hall facility A B 5 4244 4245 Butt On Shelf    
223214 Moore Hall facility A A 6 4244.8 4253 Slabbed On Shelf    
222860 Moore Hall facility A B 4 4245 4248 Butt On Shelf start of core 14; 7 boxes  
222861 Moore Hall facility A B 4 4248 4251 Butt On Shelf    
222862 Moore Hall facility A B 4 4251 4253 Butt On Shelf    
223215 Moore Hall facility A A 6 4253 4262 Slabbed On Shelf    
222863 Moore Hall facility A B 4 4253 4256 Butt On Shelf    
222864 Moore Hall facility A B 4 4256 4259 Butt On Shelf    
222865 Moore Hall facility A B 4 4259 4262 Butt On Shelf    
223216 Moore Hall facility A A 6 4262 4264.5 Slabbed On Shelf    
222866 Moore Hall facility A B 4 4262 4264 Butt On Shelf    
222867 Moore Hall facility A B 4 4267 4270 Butt On Shelf    
223217 Moore Hall facility A A 6 4267 4276 Slabbed On Shelf    
222868 Moore Hall facility A B 4 4270 4273 Butt On Shelf    
222869 Moore Hall facility A B 4 4273 4276 Butt On Shelf    
222870 Moore Hall facility A B 4 4276 4279 Butt On Shelf    
223218 Moore Hall facility A A 6 4276 4281.4 Slabbed On Shelf    
222871 Moore Hall facility A B 4 4279 4281 Butt On Shelf    
222872 Moore Hall facility A B 4 4294 4297 Butt On Shelf    
223219 Moore Hall facility A A 6 4294 4303 Slabbed On Shelf    
222873 Moore Hall facility A B 4 4297 4300 Butt On Shelf    
220662 North Lawrence facility A A 5 4300 4640 Cuttings On Shelf Box 7 of 9  
222874 Moore Hall facility A B 4 4300 4303 Butt On Shelf    
222875 Moore Hall facility A B 4 4303 4306 Butt On Shelf    
223220 Moore Hall facility A A 6 4303 4312 Slabbed On Shelf    
222876 Moore Hall facility A B 4 4306 4309 Butt On Shelf    
222877 Moore Hall facility A B 4 4309 4312 Butt On Shelf    
223221 Moore Hall facility A A 6 4312 4321 Slabbed On Shelf    
222878 Moore Hall facility A B 4 4312 4315 Butt On Shelf    
222879 Moore Hall facility A B 4 4315 4318 Butt On Shelf    
222880 Moore Hall facility A B 4 4318 4321 Butt On Shelf    
223222 Moore Hall facility A A 6 4321 4330 Slabbed On Shelf    
222881 Moore Hall facility A B 4 4321 4323 Butt On Shelf    
222882 Moore Hall facility A B 4 4323 4326 Butt On Shelf    
222883 Moore Hall facility A B 4 4326 4329 Butt On Shelf    
222884 Moore Hall facility A B 4 4329 4332 Butt On Shelf    
223223 Moore Hall facility A A 6 4330 4339 Slabbed On Shelf    
222885 Moore Hall facility A B 4 4332 4335 Butt On Shelf    
222886 Moore Hall facility A B 4 4335 4338 Butt On Shelf    
222887 Moore Hall facility A B 4 4338 4341 Butt On Shelf    
223224 Moore Hall facility A A 6 4339 4348 Slabbed On Shelf    
222888 Moore Hall facility A B 4 4341 4344 Butt On Shelf    
222889 Moore Hall facility A B 4 4344 4347 Butt On Shelf    
222890 Moore Hall facility A B 4 4347 4350 Butt On Shelf    
223225 Moore Hall facility A A 6 4348 4353.8 Slabbed On Shelf    
222891 Moore Hall facility A B 4 4350 4353 Butt On Shelf    
222892 Moore Hall facility A B 4 4353 4354 Butt On Shelf    
223226 Moore Hall facility A A 6 4353.8 4362 Slabbed On Shelf    
222894 Moore Hall facility A B 4 4357 4360 Butt On Shelf    
222895 Moore Hall facility A B 5 4360 4363 Butt On Shelf    
223227 Moore Hall facility A A 6 4362 4371 Slabbed On Shelf    
222896 Moore Hall facility A B 5 4363 4366 Butt On Shelf    
222897 Moore Hall facility A B 4 4366 4369 Butt On Shelf    
222898 Moore Hall facility A B 5 4369 4372 Butt On Shelf    
223228 Moore Hall facility A A 6 4371 4380 Slabbed On Shelf    
222899 Moore Hall facility A B 4 4372 4375 Butt On Shelf    
222900 Moore Hall facility A B 4 4375 4378 Butt On Shelf    
222901 Moore Hall facility A B 4 4378 4381 Butt On Shelf    
223229 Moore Hall facility A A 6 4380 4389 Slabbed On Shelf    
222902 Moore Hall facility A B 4 4381 4383 Butt On Shelf    
222903 Moore Hall facility A B 4 4383 4386 Butt On Shelf    
222904 Moore Hall facility A B 4 4386 4387 Butt On Shelf    
222905 Moore Hall facility A B 4 4387 4390 Butt On Shelf    
223230 Moore Hall facility A A 6 4389 4398 Slabbed On Shelf    
222906 Moore Hall facility A B 4 4390 4393 Butt On Shelf    
222907 Moore Hall facility A B 4 4393 4396 Butt On Shelf    
222908 Moore Hall facility A B 4 4396 4399 Butt On Shelf    
223231 Moore Hall facility A A 6 4398 4407 Slabbed On Shelf    
222909 Moore Hall facility A B 4 4399 4402 Butt On Shelf    
222910 Moore Hall facility A B 4 4402 4405 Butt On Shelf    
222911 Moore Hall facility A B 4 4405 4408 Butt On Shelf    
223232 Moore Hall facility A A 6 4407 4413.8 Slabbed On Shelf    
222912 Moore Hall facility A B 4 4408 4411 Butt On Shelf    
222913 Moore Hall facility A B 4 4411 4413 Butt On Shelf    
222914 Moore Hall facility A B 4 4413 4414 Butt On Shelf    
222915 Moore Hall facility A B 4 4414 4417 Butt On Shelf    
223233 Moore Hall facility A A 6 4414.4 4423 Slabbed On Shelf    
222916 Moore Hall facility A B 4 4417 4420 Butt On Shelf    
222917 Moore Hall facility A B 4 4420 4422 Butt On Shelf    
222918 Moore Hall facility A B 4 4422 4425 Butt On Shelf    
223234 Moore Hall facility A A 6 4423 4432 Slabbed On Shelf    
222919 Moore Hall facility A B 4 4425 4427 Butt On Shelf    
222920 Moore Hall facility A B 4 4427 4430 Butt On Shelf    
222921 Moore Hall facility A B 4 4430 4433 Butt On Shelf    
223235 Moore Hall facility A A 6 4432 4441 Slabbed On Shelf    
222922 Moore Hall facility A B 4 4433 4436 Butt On Shelf    
222923 Moore Hall facility A B 4 4436 4438 Butt On Shelf    
222924 Moore Hall facility A B 4 4438 4441 Butt On Shelf    
223236 Moore Hall facility A A 6 4441 4450 Slabbed On Shelf    
222925 Moore Hall facility A B 4 4441 4443 Butt On Shelf    
222926 Moore Hall facility A B 4 4443 4446 Butt On Shelf    
222927 Moore Hall facility A B 4 4446 4449 Butt On Shelf    
222928 Moore Hall facility A B 4 4449 4452 Butt On Shelf    
223237 Moore Hall facility A A 6 4450 4459 Slabbed On Shelf    
222929 Moore Hall facility A B 4 4452 4454 Butt On Shelf    
222930 Moore Hall facility A B 4 4454 4457 Butt On Shelf    
222931 Moore Hall facility A B 4 4457 4460 Butt On Shelf    
223238 Moore Hall facility A A 6 4459 4464.1 Slabbed On Shelf    
222932 Moore Hall facility A B 4 4460 4463 Butt On Shelf    
222933 Moore Hall facility A B 4 4463 4464 Butt On Shelf    
222934 Moore Hall facility A B 4 4464 4465 Butt On Shelf    
223239 Moore Hall facility A A 6 4464.1 4473 Slabbed On Shelf    
222935 Moore Hall facility A B 4 4465 4467 Butt On Shelf    
222936 Moore Hall facility A B 4 4467 4470 Butt On Shelf    
222937 Moore Hall facility A B 4 4470 4473 Butt On Shelf    
222938 Moore Hall facility A B 4 4473 4476 Butt On Shelf    
223240 Moore Hall facility A A 6 4473 4482 Slabbed On Shelf    
403510 Moore Hall facility A A 5 4475.1 4794.1 Core Samples On Shelf End trims at depths: 4475.10, 4496.10, 4504.00, 4507.85, 4514.30, 4519.00, 4523.10, 4534.70, 4543.40, 4550.90, 4557.10, 4570.10, 4598.30, 4609.90, 4626.90, 4632.90, 4640.60, 4645.90, 4649.10, 4683.40, 4728.60, 4732.40, 4743.90, 4748.25, 4755.95, 4772.30, 4778.30, 4759.65, 4790.10, 4794.10  
222939 Moore Hall facility A B 4 4476 4479 Butt On Shelf    
222940 Moore Hall facility A B 3 4479 4482 Butt On Shelf    
223241 Moore Hall facility A A 6 4482 4491 Slabbed On Shelf    
222941 Moore Hall facility A B 4 4482 4485 Butt On Shelf    
222942 Moore Hall facility A B 4 4485 4488 Butt On Shelf    
222943 Moore Hall facility A B 4 4488 4491 Butt On Shelf    
222944 Moore Hall facility A B 4 4491 4493 Butt On Shelf    
223242 Moore Hall facility A A 6 4491 4500 Slabbed On Shelf    
222945 Moore Hall facility A B 4 4493 4494 Butt On Shelf    
222946 Moore Hall facility A B 4 4494 4497 Butt On Shelf    
222947 Moore Hall facility A B 4 4497 4500 Butt On Shelf    
223243 Moore Hall facility A A 6 4500 4509 Slabbed On Shelf    
222948 Moore Hall facility A B 4 4500 4503 Butt On Shelf    
222949 Moore Hall facility A B 4 4503 4506 Butt On Shelf    
222950 Moore Hall facility A B 4 4506 4509 Butt On Shelf    
222951 Moore Hall facility A B 4 4509 4511 Butt On Shelf    
223244 Moore Hall facility A A 6 4509 4518 Slabbed On Shelf    
222952 Moore Hall facility A B 4 4511 4514 Butt On Shelf    
222953 Moore Hall facility A B 4 4514 4517 Butt On Shelf    
222954 Moore Hall facility A B 4 4517 4518 Butt On Shelf    
222955 Moore Hall facility A B 4 4518 4521 Butt On Shelf    
223245 Moore Hall facility A A 6 4518 4521 Slabbed On Shelf    
222956 Moore Hall facility A B 3 4521 4524 Butt On Shelf    
223246 Moore Hall facility A A 6 4521 4530 Slabbed On Shelf    
222957 Moore Hall facility A B 3 4524 4527 Butt On Shelf    
222958 Moore Hall facility A B 3 4527 4530 Butt On Shelf    
222959 Moore Hall facility A B 3 4530 4533 Butt On Shelf    
223247 Moore Hall facility A A 6 4530 4539 Slabbed On Shelf    
222960 Moore Hall facility A B 3 4533 4536 Butt On Shelf    
222961 Moore Hall facility A B 3 4536 4539 Butt On Shelf    
222962 Moore Hall facility A B 3 4539 4542 Butt On Shelf    
223248 Moore Hall facility A A 6 4539 4548 Slabbed On Shelf    
222963 Moore Hall facility A B 3 4542 4545 Butt On Shelf    
222964 Moore Hall facility A B 3 4545 4547 Butt On Shelf    
222965 Moore Hall facility A B 3 4547 4550 Butt On Shelf    
223249 Moore Hall facility A A 6 4548 4557 Slabbed On Shelf    
222966 Moore Hall facility A B 3 4550 4553 Butt On Shelf    
222967 Moore Hall facility A B 3 4553 4556 Butt On Shelf    
222968 Moore Hall facility A B 3 4556 4559 Butt On Shelf    
223250 Moore Hall facility A A 6 4557 4566 Slabbed On Shelf    
222969 Moore Hall facility A B 3 4559 4562 Butt On Shelf    
222970 Moore Hall facility A B 3 4562 4565 Butt On Shelf    
222971 Moore Hall facility A B 3 4565 4568 Butt On Shelf    
223251 Moore Hall facility A A 6 4566 4575 Slabbed On Shelf    
222972 Moore Hall facility A B 3 4568 4571 Butt On Shelf    
222973 Moore Hall facility A B 3 4571 4574 Butt On Shelf    
222974 Moore Hall facility A B 3 4574 4576 Butt On Shelf    
223252 Moore Hall facility A A 6 4575 4575.5 Slabbed On Shelf    
223253 Moore Hall facility A A 6 4575.5 4584 Slabbed On Shelf    
222975 Moore Hall facility A B 3 4576 4577 Butt On Shelf    
222976 Moore Hall facility A B 3 4577 4580 Butt On Shelf    
222977 Moore Hall facility A B 3 4580 4583 Butt On Shelf    
222978 Moore Hall facility A B 3 4583 4585 Butt On Shelf    
223254 Moore Hall facility A A 6 4584 4585.2 Slabbed On Shelf    
222979 Moore Hall facility A B 3 4585 4588 Butt On Shelf    
223255 Moore Hall facility A A 6 4585.4 4594 Slabbed On Shelf    
222980 Moore Hall facility A B 3 4588 4591 Butt On Shelf    
222981 Moore Hall facility A B 3 4591 4594 Butt On Shelf    
223256 Moore Hall facility A A 6 4594 4602 Slabbed On Shelf    
222982 Moore Hall facility A B 3 4594 4597 Butt On Shelf    
222983 Moore Hall facility A B 3 4597 4598 Butt On Shelf    
222984 Moore Hall facility A B 3 4598 4600 Butt On Shelf    
222985 Moore Hall facility A B 3 4600 4603 Butt On Shelf    
223257 Moore Hall facility A A 6 4602 4603 Slabbed On Shelf    
223258 Moore Hall facility A A 6 4603.6 4612 Slabbed On Shelf    
222986 Moore Hall facility A B 3 4604 4607 Butt On Shelf    
222987 Moore Hall facility A B 3 4607 4609 Butt On Shelf    
222988 Moore Hall facility A B 3 4609 4612 Butt On Shelf    
223259 Moore Hall facility A A 6 4612 4621 Slabbed On Shelf    
222989 Moore Hall facility A B 3 4612 4615 Butt On Shelf    
222990 Moore Hall facility A B 3 4615 4618 Butt On Shelf    
222991 Moore Hall facility A B 3 4618 4621 Butt On Shelf    
222992 Moore Hall facility A B 3 4621 4624 Butt On Shelf    
223260 Moore Hall facility A A 6 4621 4625 Slabbed On Shelf    
222993 Moore Hall facility A B 3 4624 4625 Butt On Shelf    
222994 Moore Hall facility A B 3 4625 4628 Butt On Shelf    
223261 Moore Hall facility A A 6 4625 4633 Slabbed On Shelf    
222995 Moore Hall facility A B 3 4628 4630 Butt On Shelf    
222996 Moore Hall facility A B 3 4630 4632 Butt On Shelf    
222997 Moore Hall facility A B 3 4632 4635 Butt On Shelf    
223262 Moore Hall facility A A 6 4633 4642 Slabbed On Shelf    
222998 Moore Hall facility A B 3 4635 4638 Butt On Shelf    
222999 Moore Hall facility A B 3 4638 4639 Butt On Shelf    
223000 Moore Hall facility A B 3 4639 4641 Butt On Shelf    
220663 North Lawrence facility A A 5 4640 4860 Cuttings On Shelf Box 8 of 9  
223001 Moore Hall facility A B 3 4641 4644 Butt On Shelf    
223263 Moore Hall facility A A 6 4642 4651 Slabbed On Shelf    
223002 Moore Hall facility A B 3 4644 4647 Butt On Shelf    
223003 Moore Hall facility A B 3 4647 4650 Butt On Shelf    
223004 Moore Hall facility A B 3 4650 4653 Butt On Shelf    
223264 Moore Hall facility A A 6 4651 4656 Slabbed On Shelf    
223005 Moore Hall facility A B 3 4653 4656 Butt On Shelf    
223265 Moore Hall facility A A 5 4680 4688 Slabbed On Shelf    
223006 Moore Hall facility A B 3 4680 4683 Butt On Shelf    
223007 Moore Hall facility A B 3 4683 4686 Butt On Shelf    
223008 Moore Hall facility A B 3 4686 4688 Butt On Shelf    
223266 Moore Hall facility A A 5 4727 4736 Slabbed On Shelf    
223009 Moore Hall facility A B 3 4727 4730 Butt On Shelf    
223010 Moore Hall facility A B 3 4730 4733 Butt On Shelf    
223011 Moore Hall facility A B 3 4733 4736 Butt On Shelf    
223267 Moore Hall facility A A 5 4736 4745 Slabbed On Shelf    
223012 Moore Hall facility A B 3 4736 4739 Butt On Shelf    
223013 Moore Hall facility A B 3 4739 4742 Butt On Shelf    
223014 Moore Hall facility A B 3 4742 4745 Butt On Shelf    
223015 Moore Hall facility A B 3 4745 4747 Butt On Shelf    
223268 Moore Hall facility A A 5 4745 4749 Slabbed On Shelf    
223016 Moore Hall facility A B 3 4747 4749 Butt On Shelf    
223017 Moore Hall facility A B 3 4749 4752 Butt On Shelf    
223269 Moore Hall facility A A 5 4749 4757 Slabbed On Shelf    
223018 Moore Hall facility A B 3 4752 4755 Butt On Shelf    
223019 Moore Hall facility A B 3 4755 4758 Butt On Shelf    
223270 Moore Hall facility A A 5 4757 4766 Slabbed On Shelf    
223020 Moore Hall facility A B 3 4758 4761 Butt On Shelf    
223021 Moore Hall facility A B 3 4761 4764 Butt On Shelf    
223022 Moore Hall facility A B 3 4764 4767 Butt On Shelf    
223271 Moore Hall facility A A 5 4766 4775 Slabbed On Shelf    
223023 Moore Hall facility A B 3 4767 4769 Butt On Shelf    
223024 Moore Hall facility A B 3 4769 4772 Butt On Shelf    
223025 Moore Hall facility A B 3 4772 4774 Butt On Shelf    
223026 Moore Hall facility A B 3 4774 4777 Butt On Shelf    
223272 Moore Hall facility A A 5 4775 4784 Slabbed On Shelf    
223027 Moore Hall facility A B 3 4777 4780 Butt On Shelf    
223028 Moore Hall facility A B 3 4780 4783 Butt On Shelf    
223029 Moore Hall facility A B 3 4783 4786 Butt On Shelf    
223273 Moore Hall facility A A 5 4784 4793 Slabbed On Shelf    
223030 Moore Hall facility A B 3 4786 4789 Butt On Shelf    
223031 Moore Hall facility A B 3 4789 4792 Butt On Shelf    
223032 Moore Hall facility A B 3 4792 4795 Butt On Shelf    
223274 Moore Hall facility A A 5 4793 4798.3 Slabbed On Shelf    
223033 Moore Hall facility A B 3 4795 4797 Butt On Shelf    
223034 Moore Hall facility A B 3 4797 4798 Butt On Shelf    
223275 Moore Hall facility A A 5 4800 4808 Slabbed On Shelf    
223035 Moore Hall facility A B 3 4800 4803 Butt On Shelf    
403511 Moore Hall facility A A 5 4801.3 5176.9 Core Samples On Shelf End trims and a few 1.5" diameter plugs at depths: 4801.30, 4815.60, 4903.80, 4906.35, 4906.35, 4913.35, 4916.60. 4923.70, 4925.70, 4929.10, 4937.05, 4949.40, 5078.10, 4985.75, 5085.80, 5104.90, 5108.10, 5127.00, 5117.00, 5142.65, 5142.65, 5170.90, 5176.90 Reagan at 5140
223036 Moore Hall facility A B 3 4803 4806 Butt On Shelf    
223037 Moore Hall facility A B 3 4806 4808 Butt On Shelf    
223276 Moore Hall facility A A 5 4808 4817 Slabbed On Shelf    
223038 Moore Hall facility A B 3 4808 4811 Butt On Shelf    
223039 Moore Hall facility A B 3 4811 4814 Butt On Shelf    
223040 Moore Hall facility A B 3 4814 4817 Butt On Shelf    
223277 Moore Hall facility A A 5 4817 4819 Slabbed On Shelf    
223041 Moore Hall facility A B 3 4817 4819 Butt On Shelf    
220664 North Lawrence facility A A 5 4860 5240 Cuttings On Shelf Box 9 of 9 Reagan at 5140
223042 Moore Hall facility A B 3 4900 4903 Butt On Shelf    
223278 Moore Hall facility A A 5 4900 4909 Slabbed On Shelf    
223043 Moore Hall facility A B 2 4903 4906 Butt On Shelf    
223044 Moore Hall facility A B 2 4906 4909 Butt On Shelf    
223045 Moore Hall facility A B 3 4909 4912 Butt On Shelf    
223279 Moore Hall facility A A 5 4909 4918 Slabbed On Shelf    
223046 Moore Hall facility A B 3 4912 4915 Butt On Shelf    
223047 Moore Hall facility A B 3 4915 4917 Butt On Shelf    
223048 Moore Hall facility A B 3 4917 4919 Butt On Shelf    
223280 Moore Hall facility A A 5 4918 4927 Slabbed On Shelf    
223049 Moore Hall facility A B 3 4919 4921 Butt On Shelf    
223050 Moore Hall facility A B 3 4921 4924 Butt On Shelf    
223051 Moore Hall facility A B 3 4924 4927 Butt On Shelf    
223281 Moore Hall facility A A 5 4927 4936 Slabbed On Shelf    
223052 Moore Hall facility A B 3 4927 4928 Butt On Shelf    
223053 Moore Hall facility A B 3 4928 4931 Butt On Shelf    
223054 Moore Hall facility A B 3 4931 4934 Butt On Shelf    
223055 Moore Hall facility A B 3 4934 4937 Butt On Shelf    
223282 Moore Hall facility A A 5 4936 4945 Slabbed On Shelf    
223056 Moore Hall facility A B 3 4937 4939 Butt On Shelf    
223057 Moore Hall facility A B 3 4939 4941 Butt On Shelf    
223058 Moore Hall facility A B 3 4941 4944 Butt On Shelf    
223059 Moore Hall facility A B 3 4944 4947 Butt On Shelf    
223283 Moore Hall facility A A 5 4945 4954 Slabbed On Shelf    
223060 Moore Hall facility A B 3 4947 4950 Butt On Shelf    
223061 Moore Hall facility A B 3 4950 4952 Butt On Shelf    
223062 Moore Hall facility A B 3 4952 4955 Butt On Shelf    
223284 Moore Hall facility A A 5 4954 4959 Slabbed On Shelf    
223063 Moore Hall facility A B 3 4955 4956 Butt On Shelf    
223064 Moore Hall facility A B 3 4956 4959 Butt On Shelf    
223065 Moore Hall facility A B 3 4959 4962 Butt On Shelf    
223285 Moore Hall facility A A 5 4959 4968 Slabbed On Shelf    
223066 Moore Hall facility A B 3 4962 4965 Butt On Shelf    
223067 Moore Hall facility A B 3 4965 4968 Butt On Shelf    
223068 Moore Hall facility A B 3 4968 4971 Butt On Shelf    
223286 Moore Hall facility A A 5 4968 4977 Slabbed On Shelf    
223069 Moore Hall facility A B 3 4971 4973 Butt On Shelf    
223070 Moore Hall facility A B 3 4973 4976 Butt On Shelf    
223071 Moore Hall facility A B 3 4976 4979 Butt On Shelf    
223287 Moore Hall facility A A 5 4977 4986 Slabbed On Shelf    
223072 Moore Hall facility A B 3 4979 4981 Butt On Shelf    
223073 Moore Hall facility A B 3 4981 4984 Butt On Shelf    
223074 Moore Hall facility A B 2 4984 4986 Butt On Shelf    
223288 Moore Hall facility A A 5 4986 4986.3 Slabbed On Shelf    
223289 Moore Hall facility A A 5 4986.5 4995 Slabbed On Shelf    
223075 Moore Hall facility A B 2 4987 4989 Butt On Shelf start of core 32; 4 boxes  
223076 Moore Hall facility A B 3 4989 4992 Butt On Shelf    
223077 Moore Hall facility A B 3 4992 4995 Butt On Shelf    
223078 Moore Hall facility A B 2 4995 4998 Butt On Shelf    
223290 Moore Hall facility A A 5 4995 4997.7 Slabbed On Shelf    
223291 Moore Hall facility A A 5 5050 5059 Slabbed On Shelf    
223079 Moore Hall facility A B 2 5050 5053 Butt On Shelf    
223080 Moore Hall facility A B 2 5053 5056 Butt On Shelf    
223081 Moore Hall facility A B 2 5056 5059 Butt On Shelf    
223292 Moore Hall facility A A 5 5059 5068 Slabbed On Shelf    
223082 Moore Hall facility A B 2 5059 5062 Butt On Shelf    
223083 Moore Hall facility A B 2 5062 5065 Butt On Shelf    
223084 Moore Hall facility A B 2 5065 5068 Butt On Shelf    
223293 Moore Hall facility A A 5 5068 5077 Slabbed On Shelf    
223085 Moore Hall facility A B 2 5068 5071 Butt On Shelf    
223086 Moore Hall facility A B 2 5071 5074 Butt On Shelf    
223087 Moore Hall facility A B 2 5074 5077 Butt On Shelf    
223088 Moore Hall facility A B 2 5077 5080 Butt On Shelf    
223294 Moore Hall facility A A 5 5077 5083 Slabbed On Shelf    
223089 Moore Hall facility A B 2 5080 5082 Butt On Shelf    
223090 Moore Hall facility A B 2 5082 5083 Butt On Shelf    
223091 Moore Hall facility A B 2 5083 5086 Butt On Shelf start of core 34; 24 boxes  
223295 Moore Hall facility A A 5 5083 5092 Slabbed On Shelf    
223092 Moore Hall facility A B 2 5086 5089 Butt On Shelf    
223093 North Lawrence facility 2 3 4 5089 5090 Butt On Shelf    
223094 Moore Hall facility A B 3 5090 5093 Butt On Shelf    
223296 Moore Hall facility A A 5 5092 5101 Slabbed On Shelf    
223095 Moore Hall facility A B 2 5093 5096 Butt On Shelf    
223096 Moore Hall facility A B 3 5096 5099 Butt On Shelf    
223097 Moore Hall facility A B 3 5099 5102 Butt On Shelf    
223297 Moore Hall facility A A 5 5101 5110 Slabbed On Shelf    
223098 Moore Hall facility A B 2 5102 5103 Butt On Shelf    
223099 Moore Hall facility A B 2 5103 5106 Butt On Shelf    
223100 Moore Hall facility A B 2 5106 5108 Butt On Shelf    
223101 Moore Hall facility A B 2 5108 5110 Butt On Shelf    
223102 Moore Hall facility A B 2 5110 5113 Butt On Shelf    
223298 Moore Hall facility A A 5 5110 5119 Slabbed On Shelf    
223103 Moore Hall facility A B 2 5113 5116 Butt On Shelf    
223104 Moore Hall facility A B 2 5116 5119 Butt On Shelf    
223105 Moore Hall facility A B 2 5119 5122 Butt On Shelf    
223299 Moore Hall facility A A 5 5119 5128 Slabbed On Shelf    
223106 Moore Hall facility A B 2 5122 5125 Butt On Shelf    
223108 Moore Hall facility A B 2 5125 5128 Butt On Shelf    
223107 Moore Hall facility A B 2 5125 5125 Butt On Shelf    
223109 Moore Hall facility A B 2 5128 5131 Butt On Shelf    
223300 Moore Hall facility A A 5 5128 5137 Slabbed On Shelf    
223110 Moore Hall facility A B 2 5131 5134 Butt On Shelf    
223111 Moore Hall facility A B 2 5134 5137 Butt On Shelf    
223301 Moore Hall facility A A 5 5137 5143.4 Slabbed On Shelf   Reagan at 5140
223112 Moore Hall facility A B 2 5137 5140 Butt On Shelf    
223113 Moore Hall facility A B 2 5140 5143 Butt On Shelf    
223114 Moore Hall facility A B 2 5143 5143.4 Butt On Shelf    
223115 Moore Hall facility A B 2 5143.4 5146 Butt On Shelf    
223302 Moore Hall facility A A 5 5143.4 5152 Slabbed On Shelf    
223116 Moore Hall facility A B 2 5146 5147 Butt On Shelf    
223117 Moore Hall facility A B 2 5147 5150 Butt On Shelf    
223118 Moore Hall facility A B 2 5150 5153 Butt On Shelf    
223303 Moore Hall facility A A 5 5152 5161 Slabbed On Shelf    
223119 Moore Hall facility A B 2 5153 5156 Butt On Shelf    
223120 Moore Hall facility A B 2 5156 5159 Butt On Shelf    
223121 Moore Hall facility A B 2 5159 5161 Butt On Shelf    
223122 Moore Hall facility A B 2 5161 5163 Butt On Shelf    
223304 Moore Hall facility A A 3 5161 5170 Slabbed On Shelf    
223123 Moore Hall facility A B 2 5163 5166 Butt On Shelf    
223124 Moore Hall facility A B 2 5166 5169 Butt On Shelf    
223125 Moore Hall facility A B 2 5169 5172 Butt On Shelf    
223305 Moore Hall facility A A 3 5170 5179 Slabbed On Shelf   Granite at 5174
223126 Moore Hall facility A B 2 5172 5175 Butt On Shelf   Granite at 5174
223127 Moore Hall facility A B 2 5175 5175 Butt On Shelf    
223128 Moore Hall facility A B 2 5175 5178 Butt On Shelf    
223129 Moore Hall facility A B 2 5178 5179 Butt On Shelf    

Tops Data

Formation
(source name)
TopBaseSourceUpdated
Heebner Shale 2406   Completion Report Dec-07-2012
Iatan 2680   Completion Report Dec-07-2012
Stalnaker 2691   Completion Report Dec-07-2012
Lansing/ Kansas City 3041   Completion Report Dec-07-2012
Stark Shale 3168   Completion Report Dec-07-2012
Pawnee 3450   Completion Report Dec-07-2012
Fort Scott 3490   Completion Report Dec-07-2012
Cherokee 3504   Completion Report Dec-07-2012
Mississippi 3658   Completion Report Dec-07-2012
Simpson Shale 4100   Completion Report Dec-07-2012
Arbuckle 4164   Completion Report Dec-07-2012
Reagan 5140   Completion Report Dec-07-2012
Granite 5174   Completion Report Dec-07-2012
Kansas City 3284 Completion Report Dec-07-2012

DST Data

Scans
Available

Images of core, thin sections, and SEM photos

View images for this well

Information from Outside Sources

Please note: The link below takes you away from the web site of the Kansas Geological Survey to the website of the Kansas Geological Society, a library in Wichita. The Survey can not help with information presented by the Walters Digital Library.

From Kansas Geological Society's Walters Digital Library


Kansas Geological Survey, Oil and Gas Well Database
Comments to webadmin@kgs.ku.edu
URL=http://www.kgs.ku.edu/Magellan/Qualified/index.html
Data added continuously.