ACO-1 and Driller's Logs
PDF files from the KGS
|
Documents from the KCC
-
Intent To Drill Well
(received by KGS Jul 18, 2012)
-
Well Completion Report
(received by KGS Feb 12, 2013)
-
Drill Stem Test
(received by KGS Feb 12, 2013)
-
Drill Stem Test
(received by KGS Feb 12, 2013)
-
Application for Temporary Abandonment - Approved
(received by KGS Jun 30, 2017)
-
Application for Temporary Abandonment - Approved
(received by KGS Jun 27, 2016)
-
Application for Temporary Abandonment - Approved
(received by KGS Jul 03, 2018)
-
Cement Tickets
(received by KGS Feb 12, 2013)
-
Cement Tickets
(received by KGS Feb 12, 2013)
-
Cement Tickets
(received by KGS Feb 12, 2013)
-
Pit Closure - Drilling Pit
(received by KGS Feb 20, 2014)
-
Plotted Geological Report/Mud Log
(received by KGS Feb 12, 2013)
-
Well Map
(received by KGS Jul 18, 2012)
-
Well Map
(received by KGS Jul 18, 2012)
-
Well Map
(received by KGS Jul 18, 2012)
|
For information on software to view and use the files we distribute
on our web pages, please view our
File Format Tools page.
|
Wireline Log Header Data
Logger: Halliburton
Tool: Magnetic Resonance Imaging Log
Operator on log Berexco, LLC
Top: 3887; Bottom: 7715
Log Date: Oct-03-2012
BHT: F
Gamma Ray: Y
Spontaneous Potential: Y
Log via KCC Electronic Submittal.
Original log is in color.
|
|
Logger: Geologist's Report
Tool: Mud Log
Operator on log Berexco, LLC
Top: 3500; Bottom: 7735
Log Date: Aug-01-2012
BHT: F
Gamma Ray:
Spontaneous Potential:
Log via KCC Electronic Submittal.
Original log is in color.
|
|
Logger: Halliburton
Tool: Array Compensated True Resistivity
Operator on log Berexco, LLC
Top: 1700; Bottom: 7699
Log Date: Sep-29-2012
BHT: 167F
Gamma Ray: Y
Spontaneous Potential: Y
Log via KCC Electronic Submittal.
|
|
Logger: Halliburton
Tool: Microlog
Operator on log Berexco, LLC
Top: 1732; Bottom: 7719
Log Date: Sep-29-2012
BHT: 167F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
|
|
Logger: Halliburton
Tool: Spectral Density Dual Spaced Neutron
Operator on log Berexco, LLC
Top: 1732; Bottom: 7719
Log Date: Sep-29-2012
BHT: 167F
Gamma Ray: Y
Spontaneous Potential:
Log via KCC Electronic Submittal.
|
|
Logger: Halliburton
Tool: Compensated Spectral Natural Gamma Ray
Operator on log Berexco, LLC
Top: 3900; Bottom: 7690
Log Date: Sep-29-2012
BHT: 167F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
|
|
Logger: Halliburton
Tool: Magnetic Resonance Imaging Log
Operator on log Berexco, LLC
Top: 3889; Bottom: 7729
Log Date: Oct-29-2012
BHT: F
Gamma Ray:
Spontaneous Potential:
Log via KCC Electronic Submittal.
Original log is in color.
|
|
Logger: Halliburton
Tool: Radial Cement Bond Log
Operator on log Berexco, LLC
Top: 776; Bottom: 7597
Log Date: Jan-03-2013
BHT: 179F
Gamma Ray: Y
Spontaneous Potential:
Log via KCC Electronic Submittal.
Original log is in color.
|
|
Logger: Pioneer Energy Services
Tool: Radial Sector Bond Gamma Ray
Operator on log Berexco, LLC
Top: 0; Bottom: 7599
Log Date: Jan-04-2013
BHT: F
Gamma Ray: Y
Spontaneous Potential:
Log via KCC Electronic Submittal.
|
|
Logger: Halliburton
Tool: Extended Range Micro Imager (XRMI) Preliminary Composite
Operator on log Berexco, LLC
Top: 5233; Bottom: 7305
Log Date: Oct-02-2012
BHT: F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Original log is in color.
|
|
Logger: Halliburton
Tool: Wave Sonic Shear Wave Anisotropy 3D Rock Stresses
Operator on log Berexco, LLC
Top: 3900; Bottom: 7700
Log Date: Dec-03-2012
BHT: 167F
Gamma Ray: Y
Spontaneous Potential: Y
Holdings at: Lawrence
Original log is in color.
|
|
Logger: Halliburton
Tool: Extended Range Micro Imager (XRMI) Preliminary Composite
Operator on log Berexco, LLC
Top: 3866; Bottom: 7685
Log Date: Oct-02-2012
BHT: F
Gamma Ray:
Spontaneous Potential:
Holdings at: Lawrence
Original log is in color.
|
|
Logger: Halliburton
Tool: Extended Range Micro Imager (XRMI) Composite
Operator on log Berexco, LLC
Top: 3900; Bottom: 6000
Log Date: Dec-03-2012
BHT: F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Original log is in color.
|
|
Logger: Halliburton
Tool: Extended Range Micro Imager (XRMI) Correlation Plot
Operator on log Berexco, LLC
Top: 3900; Bottom: 7684
Log Date: Dec-03-2012
BHT: F
Gamma Ray: Y
Spontaneous Potential:
Holdings at: Lawrence
Original log is in color.
|
|
For information on software to view and use the files we distribute
on our web pages, please view our
File Format Tools page.
|
Digital Wireline Log (LAS File) available
(Right click and "Save File As" to download)
LAS 3.0 Files from CO2 Project available
Cuttings Data
Box Number: E5084
Starting Depth: 3500
Ending Depth: 4570
|
Box Number: E5086
Starting Depth: 4570
Ending Depth: 5900
Skips: 5240-5290; 5400-5410; 5610-5620; 5660-5670; 5730-5740; 5840-5860
|
Box Number: E5087
Starting Depth: 5900
Ending Depth: 7735
Skips: Numerous skips
|
Core Library Listings
Barcode |
Facility |
Aisle |
Column |
Row |
Top |
Bottom |
Core Type |
Status |
Comments |
Tops |
223449
|
Moore Hall facility
|
C
|
A
|
4
|
3500
|
4570
|
Cuttings
|
On Shelf
|
|
Topeka at 3621
|
223447
|
Moore Hall facility
|
C
|
A
|
4
|
4570
|
5900
|
Cuttings
|
On Shelf
|
|
Kansas City B at 4596
|
500285
|
Moore Hall facility
|
B
|
A
|
7
|
5233
|
5236
|
Butt
|
On Shelf
|
core 1 box 1
|
|
500589
|
Moore Hall facility
|
A
|
A
|
4
|
5233
|
5242
|
Slabbed
|
On Shelf
|
|
|
500286
|
Moore Hall facility
|
B
|
A
|
7
|
5236
|
5239
|
Butt
|
On Shelf
|
core 1 box 2
|
|
410176
|
Moore Hall facility
|
B
|
B
|
4
|
5236.55
|
5523.35
|
Core Samples
|
On Shelf
|
end trims
|
Upper Morrow Sand at 5244
|
504711
|
North Lawrence facility
|
44
|
4
|
2
|
5237.8
|
5260.1
|
Slabbed
|
On Shelf
|
|
Upper Morrow Sand at 5244
|
500287
|
Moore Hall facility
|
B
|
A
|
7
|
5239
|
5242
|
Butt
|
On Shelf
|
core 1 box 3
|
|
500590
|
Moore Hall facility
|
A
|
A
|
4
|
5242
|
5251
|
Slabbed
|
On Shelf
|
|
Upper Morrow Sand at 5244
|
500288
|
Moore Hall facility
|
B
|
A
|
7
|
5242
|
5245
|
Butt
|
On Shelf
|
core 1 box 4
|
Upper Morrow Sand at 5244
|
500289
|
Moore Hall facility
|
B
|
A
|
7
|
5245
|
5248
|
Butt
|
On Shelf
|
core 1 box 5
|
|
500290
|
Moore Hall facility
|
B
|
A
|
7
|
5248
|
5250.05
|
Butt
|
On Shelf
|
core 1 box 6
|
|
500291
|
Moore Hall facility
|
B
|
A
|
7
|
5250.1
|
5251.58
|
Butt
|
On Shelf
|
core 1 box 7
|
|
500591
|
Moore Hall facility
|
A
|
A
|
4
|
5251
|
5251.85
|
Slabbed
|
On Shelf
|
|
|
500292
|
Moore Hall facility
|
B
|
A
|
7
|
5251.6
|
5254.9
|
Butt
|
On Shelf
|
core 2 box 1
|
|
500592
|
Moore Hall facility
|
A
|
A
|
4
|
5252
|
5261
|
Slabbed
|
On Shelf
|
|
|
500293
|
Moore Hall facility
|
B
|
A
|
7
|
5254.9
|
5258
|
Butt
|
On Shelf
|
core 2 box 2
|
|
500294
|
Moore Hall facility
|
B
|
A
|
7
|
5258
|
5260.9
|
Butt
|
On Shelf
|
core 2 box 3
|
|
500295
|
Moore Hall facility
|
B
|
A
|
7
|
5260.9
|
5263.9
|
Butt
|
On Shelf
|
core 2 box 4
|
|
500593
|
Moore Hall facility
|
A
|
A
|
4
|
5261
|
5270
|
Slabbed
|
On Shelf
|
|
|
504712
|
North Lawrence facility
|
44
|
4
|
2
|
5261.3
|
5266.9
|
Slabbed
|
On Shelf
|
|
|
500296
|
Moore Hall facility
|
B
|
A
|
7
|
5263.9
|
5266.9
|
Butt
|
On Shelf
|
core 2 box 5
|
|
500297
|
Moore Hall facility
|
B
|
A
|
7
|
5266.9
|
5269.9
|
Butt
|
On Shelf
|
core 2 box 6
|
|
504713
|
North Lawrence facility
|
44
|
4
|
2
|
5267.4
|
5277.1
|
Slabbed
|
On Shelf
|
|
|
500298
|
Moore Hall facility
|
B
|
A
|
7
|
5269.9
|
5272.85
|
Butt
|
On Shelf
|
core 2 box 7
|
|
500594
|
Moore Hall facility
|
A
|
A
|
4
|
5270
|
5279
|
Slabbed
|
On Shelf
|
|
|
500299
|
Moore Hall facility
|
B
|
A
|
7
|
5272.9
|
5275.65
|
Butt
|
On Shelf
|
core 2 box 8
|
|
500300
|
Moore Hall facility
|
B
|
A
|
7
|
5275.7
|
5278.35
|
Butt
|
On Shelf
|
core 2 box 9
|
|
500301
|
Moore Hall facility
|
B
|
A
|
7
|
5278.4
|
5281.2
|
Butt
|
On Shelf
|
core 2 box 10
|
|
504714
|
North Lawrence facility
|
44
|
4
|
2
|
5278.9
|
5403.5
|
Slabbed
|
On Shelf
|
|
|
500595
|
Moore Hall facility
|
A
|
A
|
4
|
5279
|
5288
|
Slabbed
|
On Shelf
|
|
|
500302
|
Moore Hall facility
|
B
|
A
|
7
|
5281.2
|
5283.95
|
Butt
|
On Shelf
|
core 2 box 11
|
|
500303
|
Moore Hall facility
|
B
|
A
|
7
|
5284
|
5285.9
|
Butt
|
On Shelf
|
core 2 box 12
|
|
500304
|
Moore Hall facility
|
B
|
A
|
7
|
5285.9
|
5288.65
|
Butt
|
On Shelf
|
core 2 box 13
|
|
500596
|
Moore Hall facility
|
A
|
A
|
4
|
5288
|
5297
|
Slabbed
|
On Shelf
|
|
|
500305
|
Moore Hall facility
|
B
|
A
|
7
|
5288.7
|
5292
|
Butt
|
On Shelf
|
core 2 box 14
|
|
500306
|
Moore Hall facility
|
B
|
A
|
7
|
5292
|
5295
|
Butt
|
On Shelf
|
core 2 box 15
|
|
500307
|
Moore Hall facility
|
B
|
A
|
7
|
5295
|
5298
|
Butt
|
On Shelf
|
core 2 box 16
|
|
500597
|
Moore Hall facility
|
A
|
A
|
4
|
5297
|
5304.7
|
Slabbed
|
On Shelf
|
|
|
500308
|
Moore Hall facility
|
B
|
A
|
7
|
5298
|
5301
|
Butt
|
On Shelf
|
core 2 box 17
|
|
500309
|
Moore Hall facility
|
B
|
A
|
7
|
5301
|
5302.9
|
Butt
|
On Shelf
|
core 2 box 18
|
|
500310
|
Moore Hall facility
|
B
|
A
|
7
|
5302.9
|
5304.7
|
Butt
|
On Shelf
|
core 2 box 19
|
|
500001
|
Moore Hall facility
|
B
|
A
|
7
|
5400
|
5401.7
|
Butt
|
On Shelf
|
core 3 box 22
|
|
500598
|
Moore Hall facility
|
A
|
A
|
4
|
5400
|
5409
|
Slabbed
|
On Shelf
|
|
|
500002
|
Moore Hall facility
|
B
|
A
|
7
|
5401.7
|
5404.4
|
Butt
|
On Shelf
|
core 3 box 21
|
|
500003
|
Moore Hall facility
|
B
|
A
|
7
|
5404.4
|
5407.3
|
Butt
|
On Shelf
|
core 3 box 20
|
|
500004
|
Moore Hall facility
|
B
|
A
|
7
|
5407.3
|
5410.3
|
Butt
|
On Shelf
|
core 3 box 19
|
|
500599
|
Moore Hall facility
|
A
|
A
|
4
|
5409
|
5418
|
Slabbed
|
On Shelf
|
|
|
500005
|
Moore Hall facility
|
B
|
A
|
7
|
5410.3
|
5413
|
Butt
|
On Shelf
|
core 3 box 18
|
|
500006
|
Moore Hall facility
|
B
|
A
|
7
|
5413
|
5416
|
Butt
|
On Shelf
|
core 3 box 17
|
|
500007
|
Moore Hall facility
|
B
|
A
|
7
|
5416
|
5418.6
|
Butt
|
On Shelf
|
core 3 box 16
|
|
500600
|
Moore Hall facility
|
A
|
A
|
4
|
5418
|
5427
|
Slabbed
|
On Shelf
|
|
|
500008
|
Moore Hall facility
|
B
|
A
|
7
|
5418.6
|
5421.75
|
Butt
|
On Shelf
|
core 3 box 15
|
|
400173
|
North Lawrence facility
|
44
|
4
|
2
|
5420.55
|
5481.7
|
Slabbed
|
On Shelf
|
SLABBED PIECES
|
Chester formation at 5476
|
500009
|
Moore Hall facility
|
B
|
A
|
7
|
5421.8
|
5424.1
|
Butt
|
On Shelf
|
core 3 box 14
|
|
500010
|
Moore Hall facility
|
B
|
A
|
7
|
5424.1
|
5426.75
|
Butt
|
On Shelf
|
core 3 box 13
|
|
500011
|
Moore Hall facility
|
B
|
B
|
7
|
5426.8
|
5429.5
|
Butt
|
On Shelf
|
core 3 box 12
|
|
500601
|
Moore Hall facility
|
A
|
A
|
4
|
5427
|
5436
|
Slabbed
|
On Shelf
|
|
|
500012
|
Moore Hall facility
|
B
|
A
|
7
|
5429.5
|
5432.5
|
Butt
|
On Shelf
|
core 3 box 11
|
|
500013
|
Moore Hall facility
|
B
|
A
|
7
|
5432.5
|
5435
|
Butt
|
On Shelf
|
core 3 box 10
|
|
500014
|
Moore Hall facility
|
B
|
A
|
7
|
5435
|
5437.9
|
Butt
|
On Shelf
|
core 3 box 9
|
|
500602
|
Moore Hall facility
|
A
|
A
|
4
|
5436
|
5445
|
Slabbed
|
On Shelf
|
|
|
500015
|
Moore Hall facility
|
B
|
A
|
7
|
5437.9
|
5441.2
|
Butt
|
On Shelf
|
core 3 box 8
|
|
500016
|
Moore Hall facility
|
B
|
A
|
7
|
5441.2
|
5444
|
Butt
|
On Shelf
|
core 3 box 7
|
|
500017
|
Moore Hall facility
|
B
|
A
|
7
|
5444
|
5446.5
|
Butt
|
On Shelf
|
core 3 box 6
|
|
500603
|
Moore Hall facility
|
A
|
A
|
4
|
5445
|
5454
|
Slabbed
|
On Shelf
|
|
|
500018
|
Moore Hall facility
|
B
|
A
|
7
|
5446.5
|
5449.6
|
Butt
|
On Shelf
|
core 3 box 5
|
|
500019
|
Moore Hall facility
|
B
|
A
|
7
|
5449.6
|
5452.4
|
Butt
|
On Shelf
|
core 3 box 4
|
|
500020
|
Moore Hall facility
|
B
|
A
|
7
|
5452.4
|
5455.6
|
Butt
|
On Shelf
|
core 3 box 3
|
|
500604
|
Moore Hall facility
|
A
|
A
|
4
|
5454
|
5460
|
Slabbed
|
On Shelf
|
|
|
500021
|
Moore Hall facility
|
B
|
A
|
7
|
5455.6
|
5458.2
|
Butt
|
On Shelf
|
core 3 box 2
|
|
500022
|
Moore Hall facility
|
B
|
A
|
7
|
5458.2
|
5460
|
Butt
|
On Shelf
|
core 3 box 1
|
|
500023
|
Moore Hall facility
|
B
|
A
|
7
|
5460
|
5463.2
|
Butt
|
On Shelf
|
core 4 box 8
|
|
500605
|
Moore Hall facility
|
A
|
A
|
4
|
5460
|
5469
|
Slabbed
|
On Shelf
|
|
|
500024
|
Moore Hall facility
|
B
|
A
|
7
|
5463.2
|
5466.1
|
Butt
|
On Shelf
|
core 4 box 7
|
|
500025
|
Moore Hall facility
|
B
|
A
|
7
|
5466.1
|
5468.8
|
Butt
|
On Shelf
|
core 4 box 6
|
|
500026
|
Moore Hall facility
|
B
|
A
|
7
|
5468.8
|
5471.7
|
Butt
|
On Shelf
|
core 4 box 5
|
|
500606
|
Moore Hall facility
|
A
|
A
|
4
|
5469
|
5478
|
Slabbed
|
On Shelf
|
|
Chester formation at 5476
|
500027
|
Moore Hall facility
|
B
|
A
|
7
|
5471.7
|
5474.6
|
Butt
|
On Shelf
|
core 4 box 4
|
|
500028
|
Moore Hall facility
|
B
|
A
|
7
|
5474.6
|
5477.7
|
Butt
|
On Shelf
|
core 4 box 3
|
Chester formation at 5476
|
500029
|
Moore Hall facility
|
B
|
A
|
7
|
5477.7
|
5480.7
|
Butt
|
On Shelf
|
core 4 box 2
|
|
500607
|
Moore Hall facility
|
A
|
A
|
4
|
5478
|
5483
|
Slabbed
|
On Shelf
|
|
|
500030
|
Moore Hall facility
|
B
|
A
|
7
|
5480.7
|
5483
|
Butt
|
On Shelf
|
core 4 box 1
|
|
400174
|
North Lawrence facility
|
44
|
4
|
2
|
5481.7
|
5531.8
|
Slabbed
|
On Shelf
|
SLABBED PIECES
|
|
500031
|
Moore Hall facility
|
B
|
A
|
7
|
5483
|
5485.7
|
Butt
|
On Shelf
|
core 5 box 21
|
|
500608
|
Moore Hall facility
|
A
|
A
|
4
|
5483
|
5492
|
Slabbed
|
On Shelf
|
|
|
500032
|
Moore Hall facility
|
B
|
A
|
7
|
5485.7
|
5488.5
|
Butt
|
On Shelf
|
core 5 box 20
|
|
500033
|
Moore Hall facility
|
B
|
A
|
7
|
5488.5
|
5491.2
|
Butt
|
On Shelf
|
core 5 box 19
|
|
500034
|
Moore Hall facility
|
B
|
A
|
7
|
5491.2
|
5494.1
|
Butt
|
On Shelf
|
core 5 box 18
|
|
500609
|
Moore Hall facility
|
A
|
A
|
4
|
5492
|
5501
|
Slabbed
|
On Shelf
|
|
|
500035
|
Moore Hall facility
|
B
|
A
|
7
|
5494.1
|
5497
|
Butt
|
On Shelf
|
core 5 box 17
|
|
500036
|
Moore Hall facility
|
B
|
A
|
7
|
5497
|
5499.8
|
Butt
|
On Shelf
|
core 5 box 16
|
|
500037
|
Moore Hall facility
|
B
|
A
|
7
|
5499.8
|
5502.35
|
Butt
|
On Shelf
|
core 5 box 15
|
|
500610
|
Moore Hall facility
|
A
|
A
|
4
|
5501
|
5510
|
Slabbed
|
On Shelf
|
|
|
500038
|
Moore Hall facility
|
B
|
A
|
7
|
5502.4
|
5505.4
|
Butt
|
On Shelf
|
core 5 box 14
|
|
500039
|
Moore Hall facility
|
B
|
A
|
7
|
5505.4
|
5508.3
|
Butt
|
On Shelf
|
core 5 box 13
|
|
500040
|
Moore Hall facility
|
B
|
A
|
7
|
5508.3
|
5510.95
|
Butt
|
On Shelf
|
core 5 box 12
|
|
500611
|
Moore Hall facility
|
A
|
A
|
4
|
5510
|
5519
|
Slabbed
|
On Shelf
|
|
|
500041
|
Moore Hall facility
|
B
|
A
|
7
|
5511
|
5513.9
|
Butt
|
On Shelf
|
core 5 box 11
|
|
500042
|
Moore Hall facility
|
B
|
A
|
7
|
5513.9
|
5516.8
|
Butt
|
On Shelf
|
core 5 box 10
|
|
500043
|
Moore Hall facility
|
B
|
A
|
7
|
5516.8
|
5519.8
|
Butt
|
On Shelf
|
core 5 box 9
|
|
500612
|
Moore Hall facility
|
A
|
A
|
4
|
5519
|
5528
|
Slabbed
|
On Shelf
|
|
|
500044
|
Moore Hall facility
|
B
|
A
|
7
|
5519.8
|
5522.55
|
Butt
|
On Shelf
|
core 5 box 8
|
|
500045
|
Moore Hall facility
|
B
|
A
|
7
|
5522.6
|
5525.55
|
Butt
|
On Shelf
|
core 5 box 7
|
|
500046
|
Moore Hall facility
|
B
|
A
|
7
|
5525.6
|
5528.3
|
Butt
|
On Shelf
|
core 5 box 6
|
|
410182
|
Moore Hall facility
|
B
|
B
|
4
|
5526.35
|
5623.1
|
Cuttings
|
Unavailable
|
could not find when taking inventory (04/2022 - OJ)
|
Chester porosity at 5556
|
410183
|
Moore Hall facility
|
B
|
B
|
4
|
5526.35
|
5623.1
|
Core Samples
|
On Shelf
|
end trims
|
Chester porosity at 5556
|
500613
|
Moore Hall facility
|
A
|
A
|
4
|
5528
|
5537
|
Slabbed
|
On Shelf
|
|
|
500047
|
Moore Hall facility
|
B
|
A
|
7
|
5528.3
|
5530.85
|
Butt
|
On Shelf
|
core 5 box 5
|
|
500048
|
Moore Hall facility
|
B
|
A
|
7
|
5530.9
|
5533.4
|
Butt
|
On Shelf
|
core 5 box 4
|
|
500049
|
Moore Hall facility
|
B
|
A
|
7
|
5533.4
|
5536.6
|
Butt
|
On Shelf
|
core 5 box 3
|
|
500050
|
Moore Hall facility
|
B
|
A
|
7
|
5536.6
|
5539.8
|
Butt
|
On Shelf
|
core 5 box 2
|
|
500614
|
Moore Hall facility
|
A
|
A
|
4
|
5537
|
5543
|
Slabbed
|
On Shelf
|
|
|
500051
|
Moore Hall facility
|
B
|
A
|
7
|
5539.8
|
5543
|
Butt
|
On Shelf
|
core 5 box 1
|
|
500052
|
Moore Hall facility
|
B
|
A
|
7
|
5543
|
5545.95
|
Butt
|
On Shelf
|
core 6 box 22
|
|
500615
|
Moore Hall facility
|
A
|
A
|
4
|
5543
|
5552
|
Slabbed
|
On Shelf
|
|
|
500053
|
Moore Hall facility
|
B
|
A
|
6
|
5546
|
5548.9
|
Butt
|
On Shelf
|
core 6 box 21
|
|
400175
|
North Lawrence facility
|
44
|
4
|
2
|
5546.25
|
5568.4
|
Slabbed
|
On Shelf
|
|
Chester porosity at 5556
|
500054
|
Moore Hall facility
|
B
|
A
|
6
|
5548.9
|
5551.4
|
Butt
|
On Shelf
|
core 6 box 20
|
|
500055
|
Moore Hall facility
|
B
|
A
|
6
|
5551.4
|
5553.7
|
Butt
|
On Shelf
|
core 6 box 19
|
|
500616
|
Moore Hall facility
|
A
|
A
|
4
|
5552
|
5561
|
Slabbed
|
On Shelf
|
|
Chester porosity at 5556
|
500056
|
Moore Hall facility
|
B
|
A
|
6
|
5553.7
|
5556.5
|
Butt
|
On Shelf
|
core 6 box 18
|
Chester porosity at 5556
|
500057
|
Moore Hall facility
|
B
|
A
|
6
|
5556.5
|
5559.2
|
Butt
|
On Shelf
|
core 6 box 17
|
|
500058
|
Moore Hall facility
|
B
|
A
|
6
|
5559.2
|
5561.8
|
Butt
|
On Shelf
|
core 6 box 16
|
|
500617
|
Moore Hall facility
|
A
|
A
|
4
|
5561
|
5570
|
Slabbed
|
On Shelf
|
|
|
500059
|
Moore Hall facility
|
B
|
A
|
6
|
5561.8
|
5564.4
|
Butt
|
On Shelf
|
core 6 box 15
|
|
500060
|
Moore Hall facility
|
B
|
A
|
6
|
5564.4
|
5566.9
|
Butt
|
On Shelf
|
core 6 box 14
|
|
500061
|
Moore Hall facility
|
B
|
A
|
6
|
5566.9
|
5569.6
|
Butt
|
On Shelf
|
core 6 box 13
|
|
500062
|
Moore Hall facility
|
B
|
A
|
6
|
5569.6
|
5572
|
Butt
|
On Shelf
|
core 6 box 12
|
|
500618
|
Moore Hall facility
|
A
|
A
|
4
|
5570
|
5579
|
Slabbed
|
On Shelf
|
|
|
500063
|
Moore Hall facility
|
B
|
A
|
6
|
5572
|
5574.9
|
Butt
|
On Shelf
|
core 6 box 11
|
|
400176
|
North Lawrence facility
|
44
|
4
|
2
|
5573.2
|
5585.5
|
Slabbed
|
On Shelf
|
|
|
500064
|
Moore Hall facility
|
B
|
A
|
6
|
5574.9
|
5577.8
|
Butt
|
On Shelf
|
core 6 box 10
|
|
500065
|
Moore Hall facility
|
B
|
A
|
6
|
5577.8
|
5580.6
|
Butt
|
On Shelf
|
core 6 box 9
|
|
500619
|
Moore Hall facility
|
A
|
A
|
4
|
5579
|
5588
|
Slabbed
|
On Shelf
|
|
|
500066
|
Moore Hall facility
|
B
|
A
|
6
|
5580.6
|
5583.5
|
Butt
|
On Shelf
|
core 6 box 8
|
|
500067
|
Moore Hall facility
|
B
|
A
|
6
|
5583.5
|
5586.4
|
Butt
|
On Shelf
|
core 6 box 7
|
|
500068
|
Moore Hall facility
|
B
|
A
|
6
|
5586.4
|
5589.15
|
Butt
|
On Shelf
|
core 6 box 6
|
|
400177
|
North Lawrence facility
|
44
|
4
|
2
|
5586.65
|
5601.1
|
Slabbed
|
On Shelf
|
|
|
500620
|
Moore Hall facility
|
A
|
A
|
4
|
5588
|
5597
|
Slabbed
|
On Shelf
|
|
|
500069
|
Moore Hall facility
|
B
|
A
|
6
|
5589.2
|
5591.9
|
Butt
|
On Shelf
|
core 6 box 5
|
|
500070
|
Moore Hall facility
|
B
|
A
|
6
|
5591.9
|
5594.5
|
Butt
|
On Shelf
|
core 6 box 4
|
|
500071
|
Moore Hall facility
|
B
|
A
|
6
|
5594.5
|
5597.2
|
Butt
|
On Shelf
|
core 6 box 3
|
|
500621
|
Moore Hall facility
|
A
|
A
|
4
|
5597
|
5603
|
Slabbed
|
On Shelf
|
|
|
500072
|
Moore Hall facility
|
B
|
A
|
6
|
5597.2
|
5600.1
|
Butt
|
On Shelf
|
core 6 box 2
|
|
500073
|
Moore Hall facility
|
B
|
A
|
6
|
5600.1
|
5603
|
Butt
|
On Shelf
|
core 6 box 1
|
|
500622
|
Moore Hall facility
|
A
|
A
|
4
|
5603
|
5612
|
Slabbed
|
On Shelf
|
|
|
500074
|
Moore Hall facility
|
B
|
A
|
6
|
5603
|
5605.8
|
Butt
|
On Shelf
|
core 7 box 7
|
|
400178
|
North Lawrence facility
|
44
|
4
|
2
|
5604.4
|
5612.6
|
Slabbed
|
On Shelf
|
|
|
500075
|
Moore Hall facility
|
B
|
A
|
6
|
5605.8
|
5608.8
|
Butt
|
On Shelf
|
core 7 box 6
|
|
500076
|
Moore Hall facility
|
B
|
A
|
6
|
5608.8
|
5610.8
|
Butt
|
On Shelf
|
core 7 box 5
|
|
500077
|
Moore Hall facility
|
B
|
A
|
6
|
5610.8
|
5613.7
|
Butt
|
On Shelf
|
core 7 box 4
|
|
500623
|
Moore Hall facility
|
A
|
A
|
4
|
5612
|
5621
|
Slabbed
|
On Shelf
|
|
|
400179
|
North Lawrence facility
|
44
|
4
|
2
|
5612.6
|
5622
|
Slabbed
|
On Shelf
|
|
|
500078
|
Moore Hall facility
|
B
|
A
|
6
|
5613.7
|
5616
|
Butt
|
On Shelf
|
core 7 box 3
|
|
500079
|
Moore Hall facility
|
B
|
A
|
6
|
5616
|
5618.5
|
Butt
|
On Shelf
|
core 7 box 2
|
|
500080
|
Moore Hall facility
|
B
|
A
|
6
|
5618.5
|
5621
|
Butt
|
On Shelf
|
core 7 box 1
|
|
500624
|
Moore Hall facility
|
A
|
A
|
4
|
5621
|
5630
|
Slabbed
|
On Shelf
|
|
|
500081
|
Moore Hall facility
|
B
|
A
|
6
|
5621
|
5623.3
|
Butt
|
On Shelf
|
core 8 box 19
|
|
400180
|
North Lawrence facility
|
44
|
4
|
2
|
5623.25
|
5634.5
|
Slabbed
|
On Shelf
|
|
|
500082
|
Moore Hall facility
|
B
|
A
|
6
|
5623.3
|
5625.2
|
Butt
|
On Shelf
|
core 8 box 18
|
|
410175
|
Moore Hall facility
|
B
|
B
|
4
|
5624.85
|
6442.85
|
Core Samples
|
Unavailable
|
end trims - could not find when taking inventory (04/2022 - OJ)
|
St. Louis porosity at 5665
|
500083
|
Moore Hall facility
|
B
|
A
|
6
|
5625.2
|
5627.4
|
Butt
|
On Shelf
|
core 8 box 17
|
|
500084
|
Moore Hall facility
|
B
|
A
|
6
|
5627.4
|
5629.8
|
Butt
|
On Shelf
|
core 8 box 16
|
|
500085
|
Moore Hall facility
|
B
|
A
|
6
|
5629.8
|
5632.4
|
Butt
|
On Shelf
|
core 8 box 15
|
|
500625
|
Moore Hall facility
|
A
|
A
|
4
|
5630
|
5639
|
Slabbed
|
On Shelf
|
|
|
500086
|
Moore Hall facility
|
B
|
A
|
6
|
5632.4
|
5635.3
|
Butt
|
On Shelf
|
core 8 box 14
|
|
500087
|
Moore Hall facility
|
B
|
A
|
6
|
5635.3
|
5637.9
|
Butt
|
On Shelf
|
core 8 box 13
|
|
400181
|
North Lawrence facility
|
44
|
4
|
2
|
5635.5
|
5662.05
|
Slabbed
|
On Shelf
|
|
|
500088
|
Moore Hall facility
|
B
|
A
|
6
|
5637.9
|
5640.6
|
Butt
|
On Shelf
|
core 8 box 12
|
|
500626
|
Moore Hall facility
|
A
|
A
|
4
|
5639
|
5648
|
Slabbed
|
On Shelf
|
|
|
500089
|
Moore Hall facility
|
B
|
A
|
6
|
5640.6
|
5643.6
|
Butt
|
On Shelf
|
core 8 box 11
|
|
500090
|
Moore Hall facility
|
B
|
A
|
6
|
5643.6
|
5645.2
|
Butt
|
On Shelf
|
core 8 box 10
|
|
500091
|
Moore Hall facility
|
B
|
A
|
6
|
5645.2
|
5646.9
|
Butt
|
On Shelf
|
core 8 box 9
|
|
500092
|
Moore Hall facility
|
B
|
A
|
6
|
5646.9
|
5649.7
|
Butt
|
On Shelf
|
core 8 box 8
|
|
500627
|
Moore Hall facility
|
A
|
A
|
4
|
5648
|
5657
|
Slabbed
|
On Shelf
|
|
|
500093
|
Moore Hall facility
|
B
|
A
|
6
|
5649.7
|
5652.6
|
Butt
|
On Shelf
|
core 8 box 7
|
|
500094
|
Moore Hall facility
|
B
|
A
|
6
|
5652.6
|
5655.6
|
Butt
|
On Shelf
|
core 8 box 6
|
|
500095
|
Moore Hall facility
|
B
|
A
|
6
|
5655.6
|
5658.1
|
Butt
|
On Shelf
|
core 8 box 5
|
|
500628
|
Moore Hall facility
|
A
|
A
|
4
|
5657
|
5666
|
Slabbed
|
On Shelf
|
|
St. Louis porosity at 5665
|
500096
|
Moore Hall facility
|
B
|
A
|
6
|
5658.1
|
5660.9
|
Butt
|
On Shelf
|
core 8 box 4
|
|
500097
|
Moore Hall facility
|
B
|
A
|
6
|
5660.9
|
5663.3
|
Butt
|
On Shelf
|
core 8 box 3
|
|
400182
|
North Lawrence facility
|
44
|
4
|
2
|
5663.2
|
6372.2
|
Slabbed
|
On Shelf
|
708.95' jump
|
St. Louis porosity at 5665
|
500098
|
Moore Hall facility
|
B
|
A
|
6
|
5663.3
|
5666.2
|
Butt
|
On Shelf
|
core 8 box 2
|
St. Louis porosity at 5665
|
500629
|
Moore Hall facility
|
A
|
A
|
4
|
5666
|
5667.7
|
Slabbed
|
On Shelf
|
|
|
500099
|
Moore Hall facility
|
B
|
A
|
6
|
5666.2
|
5667.7
|
Butt
|
On Shelf
|
core 8 box 1
|
|
223448
|
Moore Hall facility
|
C
|
A
|
4
|
5900
|
7735
|
Cuttings
|
On Shelf
|
|
Viola at 6488
|
400200
|
North Lawrence facility
|
44
|
4
|
2
|
5983.8
|
7104.75
|
Slabbed
|
On Shelf
|
SLABBED PIECES
|
Viola at 6488
|
500630
|
Moore Hall facility
|
A
|
A
|
4
|
6360
|
6369
|
Slabbed
|
On Shelf
|
|
|
500100
|
Moore Hall facility
|
B
|
A
|
6
|
6360
|
6362.1
|
Butt
|
On Shelf
|
core 9 box 5
|
|
500101
|
Moore Hall facility
|
B
|
A
|
6
|
6362.1
|
6365
|
Butt
|
On Shelf
|
core 9 box 4
|
|
500102
|
Moore Hall facility
|
B
|
A
|
6
|
6365
|
6367.6
|
Butt
|
On Shelf
|
core 9 box 3
|
|
500103
|
Moore Hall facility
|
B
|
A
|
6
|
6367.6
|
6369.4
|
Butt
|
On Shelf
|
core 9 box 2
|
|
500631
|
Moore Hall facility
|
A
|
A
|
4
|
6369
|
6372.5
|
Slabbed
|
On Shelf
|
|
|
500104
|
Moore Hall facility
|
B
|
A
|
6
|
6369.4
|
6372.5
|
Butt
|
On Shelf
|
core 9 box 1
|
|
500105
|
Moore Hall facility
|
B
|
A
|
6
|
6372.5
|
6374.95
|
Butt
|
On Shelf
|
core 10 box 8
|
|
500632
|
Moore Hall facility
|
A
|
A
|
4
|
6373
|
6382
|
Slabbed
|
On Shelf
|
|
|
400183
|
North Lawrence facility
|
44
|
4
|
2
|
6374.9
|
6395
|
Slabbed
|
On Shelf
|
|
|
500106
|
Moore Hall facility
|
B
|
A
|
6
|
6375
|
6377.65
|
Butt
|
On Shelf
|
core 10 box 7
|
|
500107
|
Moore Hall facility
|
B
|
A
|
6
|
6377.7
|
6379.95
|
Butt
|
On Shelf
|
core 10 box 6
|
|
500108
|
Moore Hall facility
|
B
|
A
|
6
|
6380
|
6382.7
|
Butt
|
On Shelf
|
core 10 box 5
|
|
500633
|
Moore Hall facility
|
A
|
A
|
4
|
6382
|
6391
|
Slabbed
|
On Shelf
|
|
|
500109
|
Moore Hall facility
|
B
|
A
|
6
|
6382.7
|
6385.5
|
Butt
|
On Shelf
|
core 10 box 4
|
|
500110
|
Moore Hall facility
|
B
|
A
|
6
|
6385.5
|
6388.1
|
Butt
|
On Shelf
|
core 10 box 3
|
|
500111
|
Moore Hall facility
|
B
|
A
|
6
|
6388.1
|
6390.6
|
Butt
|
On Shelf
|
core 10 box 2
|
|
500112
|
Moore Hall facility
|
B
|
A
|
6
|
6390.6
|
6393.1
|
Butt
|
On Shelf
|
core 10 box 1
|
|
500634
|
Moore Hall facility
|
A
|
A
|
4
|
6391
|
6393.1
|
Slabbed
|
On Shelf
|
|
|
500113
|
Moore Hall facility
|
B
|
A
|
6
|
6393.1
|
6396.7
|
Butt
|
On Shelf
|
core 11 box 2
|
|
500635
|
Moore Hall facility
|
A
|
A
|
4
|
6393.8
|
6399
|
Slabbed
|
On Shelf
|
|
|
400184
|
North Lawrence facility
|
44
|
4
|
2
|
6395.8
|
6446.3
|
Slabbed
|
On Shelf
|
|
|
500114
|
Moore Hall facility
|
B
|
A
|
6
|
6396.7
|
6399
|
Butt
|
On Shelf
|
core 11 box 1
|
|
500636
|
Moore Hall facility
|
A
|
A
|
4
|
6440
|
6449
|
Slabbed
|
On Shelf
|
|
|
500115
|
Moore Hall facility
|
B
|
A
|
6
|
6440
|
6442.5
|
Butt
|
On Shelf
|
core 12 box 23
|
|
500116
|
Moore Hall facility
|
B
|
A
|
6
|
6442.5
|
6445
|
Butt
|
On Shelf
|
core 12 box 22
|
|
500117
|
Moore Hall facility
|
B
|
A
|
6
|
6445
|
6447.65
|
Butt
|
On Shelf
|
core 12 box 21
|
|
500118
|
Moore Hall facility
|
B
|
A
|
6
|
6447.7
|
6450.35
|
Butt
|
On Shelf
|
core 12 box 20
|
|
410181
|
Moore Hall facility
|
B
|
B
|
4
|
6448.6
|
6695.6
|
Core Samples
|
On Shelf
|
end trims
|
Viola at 6488
|
400185
|
North Lawrence facility
|
44
|
4
|
2
|
6448.75
|
6460.95
|
Slabbed
|
On Shelf
|
|
|
500637
|
Moore Hall facility
|
A
|
A
|
4
|
6449
|
6458
|
Slabbed
|
On Shelf
|
|
|
500119
|
Moore Hall facility
|
B
|
A
|
6
|
6450.4
|
6452.65
|
Butt
|
On Shelf
|
core 12 box 19
|
|
500120
|
Moore Hall facility
|
B
|
A
|
6
|
6452.7
|
6455.05
|
Butt
|
On Shelf
|
core 12 box 18
|
|
500121
|
Moore Hall facility
|
B
|
A
|
6
|
6455.1
|
6457.6
|
Butt
|
On Shelf
|
core 12 box 17
|
|
500122
|
Moore Hall facility
|
B
|
A
|
6
|
6457.6
|
6460.17
|
Butt
|
On Shelf
|
core 12 box 16
|
|
500638
|
Moore Hall facility
|
A
|
A
|
4
|
6458
|
6467
|
Slabbed
|
On Shelf
|
|
|
500123
|
Moore Hall facility
|
B
|
A
|
6
|
6460.2
|
6462.95
|
Butt
|
On Shelf
|
core 12 box 15
|
|
500124
|
Moore Hall facility
|
B
|
A
|
6
|
6463
|
6465.5
|
Butt
|
On Shelf
|
core 12 box 14
|
|
400186
|
North Lawrence facility
|
44
|
4
|
2
|
6463.05
|
6474.85
|
Slabbed
|
On Shelf
|
|
|
500125
|
Moore Hall facility
|
B
|
A
|
6
|
6465.5
|
6468.5
|
Butt
|
On Shelf
|
core 12 box 13
|
|
500639
|
Moore Hall facility
|
A
|
A
|
4
|
6467
|
6476
|
Slabbed
|
On Shelf
|
|
|
500126
|
Moore Hall facility
|
B
|
A
|
6
|
6468.5
|
6471.2
|
Butt
|
On Shelf
|
core 12 box 12
|
|
500127
|
Moore Hall facility
|
B
|
A
|
6
|
6471.2
|
6474
|
Butt
|
On Shelf
|
core 12 box 11
|
|
500128
|
Moore Hall facility
|
B
|
A
|
6
|
6474
|
6476.7
|
Butt
|
On Shelf
|
core 12 box 10
|
|
500640
|
Moore Hall facility
|
A
|
A
|
4
|
6476
|
6485
|
Slabbed
|
On Shelf
|
|
|
500129
|
Moore Hall facility
|
B
|
A
|
6
|
6476.7
|
6479.5
|
Butt
|
On Shelf
|
core 12 box 9
|
|
400187
|
North Lawrence facility
|
44
|
4
|
2
|
6477.8
|
6501
|
Slabbed
|
On Shelf
|
|
Viola at 6488
|
500130
|
Moore Hall facility
|
B
|
A
|
6
|
6479.5
|
6482
|
Butt
|
On Shelf
|
core 12 box 8
|
|
500131
|
Moore Hall facility
|
B
|
A
|
6
|
6482
|
6484.7
|
Butt
|
On Shelf
|
core 12 box 7
|
|
500132
|
Moore Hall facility
|
B
|
A
|
6
|
6484.7
|
6487.6
|
Butt
|
On Shelf
|
core 12 box 6
|
|
500641
|
Moore Hall facility
|
A
|
A
|
4
|
6485
|
6494
|
Slabbed
|
On Shelf
|
|
Viola at 6488
|
500133
|
Moore Hall facility
|
B
|
A
|
6
|
6487.6
|
6490
|
Butt
|
On Shelf
|
core 12 box 5
|
Viola at 6488
|
500134
|
Moore Hall facility
|
B
|
A
|
6
|
6490
|
6492.6
|
Butt
|
On Shelf
|
core 12 box 4
|
|
500135
|
Moore Hall facility
|
B
|
A
|
6
|
6492.6
|
6495
|
Butt
|
On Shelf
|
core 12 box 3
|
|
500642
|
Moore Hall facility
|
A
|
A
|
4
|
6494
|
6500
|
Slabbed
|
On Shelf
|
|
|
500136
|
Moore Hall facility
|
B
|
A
|
5
|
6495
|
6497
|
Butt
|
On Shelf
|
core 12 box 2
|
|
500137
|
Moore Hall facility
|
B
|
A
|
5
|
6497
|
6500
|
Butt
|
On Shelf
|
core 12 box 1
|
|
500138
|
Moore Hall facility
|
B
|
A
|
5
|
6500
|
6502.85
|
Butt
|
On Shelf
|
core 13 box 6
|
|
500643
|
Moore Hall facility
|
A
|
A
|
4
|
6500
|
6509
|
Slabbed
|
On Shelf
|
|
|
400188
|
North Lawrence facility
|
44
|
4
|
2
|
6501.6
|
6518.55
|
Slabbed
|
On Shelf
|
|
|
500139
|
Moore Hall facility
|
B
|
A
|
5
|
6502.9
|
6505.45
|
Butt
|
On Shelf
|
core 13 box 5
|
|
500140
|
Moore Hall facility
|
B
|
A
|
5
|
6505.5
|
6508
|
Butt
|
On Shelf
|
core 13 box 4
|
|
500141
|
Moore Hall facility
|
B
|
A
|
5
|
6508
|
6510.3
|
Butt
|
On Shelf
|
core 13 box 3
|
|
500644
|
North Lawrence facility
|
44
|
4
|
2
|
6509
|
6515.7
|
Slabbed
|
On Shelf
|
|
|
500142
|
Moore Hall facility
|
B
|
A
|
5
|
6510.3
|
6512.87
|
Butt
|
On Shelf
|
core 13 box 2
|
|
500143
|
Moore Hall facility
|
B
|
A
|
5
|
6512.9
|
6515.7
|
Butt
|
On Shelf
|
core 13 box 1
|
|
500645
|
North Lawrence facility
|
44
|
4
|
2
|
6515.7
|
6524
|
Slabbed
|
On Shelf
|
|
|
500144
|
Moore Hall facility
|
B
|
A
|
5
|
6515.7
|
6518.55
|
Butt
|
On Shelf
|
core 14 box 6
|
|
500145
|
Moore Hall facility
|
B
|
A
|
5
|
6518.6
|
6520.95
|
Butt
|
On Shelf
|
core 14 box 5
|
|
400189
|
North Lawrence facility
|
44
|
4
|
2
|
6518.7
|
6657.75
|
Slabbed
|
On Shelf
|
|
|
500146
|
Moore Hall facility
|
B
|
A
|
5
|
6521
|
6523.57
|
Butt
|
On Shelf
|
core 14 box 4
|
|
500147
|
Moore Hall facility
|
B
|
A
|
5
|
6523.6
|
6526.1
|
Butt
|
On Shelf
|
core 14 box 3
|
|
500646
|
North Lawrence facility
|
44
|
4
|
2
|
6524
|
6530.8
|
Slabbed
|
On Shelf
|
|
|
500148
|
Moore Hall facility
|
B
|
A
|
5
|
6526.1
|
6528.35
|
Butt
|
On Shelf
|
core 14 box 2
|
|
500149
|
Moore Hall facility
|
B
|
A
|
5
|
6528.4
|
6530.8
|
Butt
|
On Shelf
|
core 14 box 1
|
|
500647
|
North Lawrence facility
|
44
|
4
|
2
|
6655
|
6664
|
Slabbed
|
On Shelf
|
|
|
500150
|
Moore Hall facility
|
B
|
A
|
5
|
6655
|
6657.75
|
Butt
|
On Shelf
|
core 15 box 1
|
|
500151
|
Moore Hall facility
|
B
|
A
|
5
|
6657.8
|
6660.43
|
Butt
|
On Shelf
|
core 15 box 2
|
|
400190
|
North Lawrence facility
|
44
|
4
|
2
|
6659.45
|
6672.85
|
Slabbed
|
On Shelf
|
|
|
500152
|
Moore Hall facility
|
B
|
A
|
5
|
6660.4
|
6662.91
|
Butt
|
On Shelf
|
core 15 box 3
|
|
500153
|
Moore Hall facility
|
B
|
A
|
5
|
6662.9
|
6665.65
|
Butt
|
On Shelf
|
core 15 box 4
|
|
500648
|
North Lawrence facility
|
44
|
4
|
2
|
6664
|
6673
|
Slabbed
|
On Shelf
|
|
|
500154
|
Moore Hall facility
|
B
|
A
|
5
|
6665.7
|
6668.45
|
Butt
|
On Shelf
|
core 15 box 5
|
|
500155
|
Moore Hall facility
|
B
|
A
|
5
|
6668.5
|
6671.25
|
Butt
|
On Shelf
|
core 15 box 6
|
|
500156
|
Moore Hall facility
|
B
|
A
|
5
|
6671.3
|
6673.6
|
Butt
|
On Shelf
|
core 15 box 7
|
|
500649
|
North Lawrence facility
|
44
|
4
|
2
|
6673
|
6682
|
Slabbed
|
On Shelf
|
|
|
500157
|
Moore Hall facility
|
B
|
A
|
5
|
6673.6
|
6676.13
|
Butt
|
On Shelf
|
core 15 box 8
|
|
400191
|
North Lawrence facility
|
44
|
4
|
2
|
6674.5
|
6688.2
|
Slabbed
|
On Shelf
|
|
|
500158
|
Moore Hall facility
|
B
|
A
|
5
|
6676.1
|
6678.7
|
Butt
|
On Shelf
|
core 15 box 9
|
|
500159
|
Moore Hall facility
|
B
|
A
|
5
|
6678.7
|
6681.4
|
Butt
|
On Shelf
|
core 15 box 10
|
|
500160
|
Moore Hall facility
|
B
|
A
|
5
|
6681.4
|
6684.1
|
Butt
|
On Shelf
|
core 15 box 11
|
|
500650
|
North Lawrence facility
|
44
|
4
|
2
|
6682
|
6691
|
Slabbed
|
On Shelf
|
|
Simpson Shale at 6690
|
500161
|
Moore Hall facility
|
B
|
A
|
5
|
6684.1
|
6684.4
|
Butt
|
On Shelf
|
core 15 box 12
|
|
500162
|
Moore Hall facility
|
B
|
A
|
5
|
6686.4
|
6689.3
|
Butt
|
On Shelf
|
core 15 box 13
|
|
500163
|
Moore Hall facility
|
B
|
A
|
5
|
6689.3
|
6692.1
|
Butt
|
On Shelf
|
core 15 box 14
|
Simpson Shale at 6690
|
400192
|
North Lawrence facility
|
44
|
4
|
2
|
6690
|
6704.85
|
Slabbed
|
On Shelf
|
|
|
500651
|
North Lawrence facility
|
44
|
4
|
2
|
6691
|
6700
|
Slabbed
|
On Shelf
|
|
|
500164
|
Moore Hall facility
|
B
|
A
|
5
|
6692.1
|
6695
|
Butt
|
On Shelf
|
core 15 box 15
|
|
500165
|
Moore Hall facility
|
B
|
A
|
5
|
6695
|
6697.7
|
Butt
|
On Shelf
|
core 15 box 16
|
|
410179
|
Moore Hall facility
|
B
|
B
|
4
|
6696.7
|
6931.4
|
Core Samples
|
On Shelf
|
end trims
|
Arbuckle at 6711
|
500166
|
Moore Hall facility
|
B
|
A
|
5
|
6697.7
|
6700.7
|
Butt
|
On Shelf
|
core 15 box 17
|
|
500652
|
North Lawrence facility
|
44
|
4
|
2
|
6700
|
6709
|
Slabbed
|
On Shelf
|
|
|
500167
|
Moore Hall facility
|
B
|
A
|
5
|
6700.7
|
6703.45
|
Butt
|
On Shelf
|
core 15 box 18
|
|
500168
|
Moore Hall facility
|
B
|
A
|
5
|
6703.5
|
6706.4
|
Butt
|
On Shelf
|
core 15 box 19
|
|
500169
|
Moore Hall facility
|
B
|
A
|
5
|
6706.4
|
6709
|
Butt
|
On Shelf
|
core 15 box 20
|
|
400193
|
North Lawrence facility
|
44
|
4
|
2
|
6707.3
|
6731.9
|
Slabbed
|
On Shelf
|
|
Arbuckle at 6711
|
500653
|
Moore Hall facility
|
A
|
A
|
4
|
6709
|
6715
|
Slabbed
|
On Shelf
|
|
Arbuckle at 6711
|
500170
|
Moore Hall facility
|
B
|
A
|
5
|
6709
|
6712
|
Butt
|
On Shelf
|
core 15 box 21
|
Arbuckle at 6711
|
500171
|
Moore Hall facility
|
B
|
A
|
5
|
6712
|
6715
|
Butt
|
On Shelf
|
core 15 box 22
|
|
500654
|
Moore Hall facility
|
A
|
A
|
4
|
6715
|
6724
|
Slabbed
|
On Shelf
|
|
|
500172
|
Moore Hall facility
|
B
|
A
|
5
|
6715
|
6717.75
|
Butt
|
On Shelf
|
core 16 box 1
|
|
500173
|
Moore Hall facility
|
B
|
A
|
5
|
6717.8
|
6720.5
|
Butt
|
On Shelf
|
core 16 box 2
|
|
500174
|
Moore Hall facility
|
B
|
A
|
5
|
6720.5
|
6723.25
|
Butt
|
On Shelf
|
core 16 box 3
|
|
500175
|
Moore Hall facility
|
B
|
A
|
5
|
6723.3
|
6726.3
|
Butt
|
On Shelf
|
core 16 box 4
|
|
500655
|
Moore Hall facility
|
A
|
A
|
4
|
6724
|
6733
|
Slabbed
|
On Shelf
|
|
|
500176
|
Moore Hall facility
|
B
|
A
|
5
|
6726.3
|
6729.2
|
Butt
|
On Shelf
|
core 16 box 5
|
|
500177
|
Moore Hall facility
|
B
|
A
|
5
|
6729.2
|
6732
|
Butt
|
On Shelf
|
core 16 box 6
|
|
500178
|
Moore Hall facility
|
B
|
A
|
5
|
6732
|
6734.7
|
Butt
|
On Shelf
|
core 16 box 7
|
|
500656
|
Moore Hall facility
|
A
|
A
|
4
|
6733
|
6742
|
Slabbed
|
On Shelf
|
|
|
400194
|
North Lawrence facility
|
44
|
4
|
2
|
6734.6
|
6746.6
|
Slabbed
|
On Shelf
|
|
|
500179
|
Moore Hall facility
|
B
|
A
|
5
|
6734.7
|
6737.2
|
Butt
|
On Shelf
|
core 16 box 8
|
|
500180
|
Moore Hall facility
|
B
|
A
|
5
|
6737.2
|
6740
|
Butt
|
On Shelf
|
core 16 box 9
|
|
500181
|
Moore Hall facility
|
B
|
A
|
5
|
6740
|
6742.4
|
Butt
|
On Shelf
|
core 16 box 10
|
|
500657
|
Moore Hall facility
|
A
|
A
|
4
|
6742
|
6751
|
Slabbed
|
On Shelf
|
|
|
500182
|
Moore Hall facility
|
B
|
A
|
5
|
6742.4
|
6745
|
Butt
|
On Shelf
|
core 16 box 11
|
|
500183
|
Moore Hall facility
|
B
|
A
|
5
|
6745
|
6747.9
|
Butt
|
On Shelf
|
core 16 box 12
|
|
500184
|
Moore Hall facility
|
B
|
A
|
5
|
6747.9
|
6750.4
|
Butt
|
On Shelf
|
core 16 box 13
|
|
400195
|
North Lawrence facility
|
44
|
4
|
2
|
6748.05
|
6762.5
|
Slabbed
|
On Shelf
|
|
|
500185
|
Moore Hall facility
|
B
|
A
|
5
|
6750.4
|
6753.2
|
Butt
|
On Shelf
|
core 16 box 14
|
|
500658
|
Moore Hall facility
|
A
|
A
|
4
|
6751
|
6760
|
Slabbed
|
On Shelf
|
|
|
500186
|
Moore Hall facility
|
B
|
A
|
5
|
6753.2
|
6755.9
|
Butt
|
On Shelf
|
core 16 box 15
|
|
500187
|
Moore Hall facility
|
B
|
A
|
5
|
6755.9
|
6758.5
|
Butt
|
On Shelf
|
core 16 box 16
|
|
500188
|
Moore Hall facility
|
B
|
A
|
5
|
6758.5
|
6761.05
|
Butt
|
On Shelf
|
core 16 box 17
|
|
500659
|
Moore Hall facility
|
A
|
A
|
4
|
6760
|
6769
|
Slabbed
|
On Shelf
|
|
|
500189
|
Moore Hall facility
|
B
|
A
|
5
|
6761.1
|
6763.7
|
Butt
|
On Shelf
|
core 16 box 18
|
|
500190
|
Moore Hall facility
|
B
|
A
|
5
|
6763.7
|
6766.1
|
Butt
|
On Shelf
|
core 16 box 19
|
|
500191
|
Moore Hall facility
|
B
|
A
|
5
|
6766.1
|
6768.2
|
Butt
|
On Shelf
|
core 16 box 20
|
|
500192
|
Moore Hall facility
|
B
|
A
|
5
|
6768.2
|
6769.4
|
Butt
|
On Shelf
|
core 16 box 21
|
|
500660
|
Moore Hall facility
|
A
|
A
|
4
|
6769
|
6769.4
|
Slabbed
|
On Shelf
|
|
|
500193
|
Moore Hall facility
|
B
|
A
|
5
|
6904
|
6906.9
|
Butt
|
On Shelf
|
core 18 box 1
|
|
500661
|
Moore Hall facility
|
A
|
A
|
4
|
6904
|
6913
|
Slabbed
|
On Shelf
|
|
|
400196
|
North Lawrence facility
|
44
|
4
|
2
|
6905.75
|
6921.15
|
Slabbed
|
On Shelf
|
|
|
500194
|
Moore Hall facility
|
B
|
A
|
5
|
6906.9
|
6909.6
|
Butt
|
On Shelf
|
core 18 box 2
|
|
500195
|
Moore Hall facility
|
B
|
A
|
5
|
6909.6
|
6912.3
|
Butt
|
On Shelf
|
core 18 box 3
|
|
500196
|
Moore Hall facility
|
B
|
A
|
5
|
6912.3
|
6915.2
|
Butt
|
On Shelf
|
core 18 box 4
|
|
500662
|
Moore Hall facility
|
A
|
A
|
4
|
6913
|
6922
|
Slabbed
|
On Shelf
|
|
|
500197
|
Moore Hall facility
|
B
|
A
|
5
|
6915.2
|
6917.6
|
Butt
|
On Shelf
|
core 18 box 5
|
|
500198
|
Moore Hall facility
|
B
|
A
|
5
|
6917.6
|
6919.9
|
Butt
|
On Shelf
|
core 18 box 6
|
|
500199
|
Moore Hall facility
|
B
|
A
|
5
|
6919.9
|
6922.1
|
Butt
|
On Shelf
|
core 18 box 7
|
|
500663
|
Moore Hall facility
|
A
|
A
|
4
|
6922
|
6931
|
Slabbed
|
On Shelf
|
|
|
500200
|
Moore Hall facility
|
B
|
A
|
5
|
6922.1
|
6924.7
|
Butt
|
On Shelf
|
core 18 box 8
|
|
400197
|
North Lawrence facility
|
44
|
4
|
2
|
6923.55
|
6943.2
|
Slabbed
|
On Shelf
|
|
|
500201
|
Moore Hall facility
|
B
|
A
|
5
|
6924.7
|
6927.4
|
Butt
|
On Shelf
|
core 18 box 9
|
|
500202
|
Moore Hall facility
|
B
|
A
|
4
|
6927.4
|
6930.2
|
Butt
|
On Shelf
|
core 18 box 10
|
|
500203
|
Moore Hall facility
|
B
|
A
|
5
|
6930.2
|
6933
|
Butt
|
On Shelf
|
core 18 box 11
|
|
500664
|
Moore Hall facility
|
A
|
A
|
4
|
6931
|
6940
|
Slabbed
|
On Shelf
|
|
|
500204
|
Moore Hall facility
|
B
|
A
|
5
|
6933
|
6935.9
|
Butt
|
On Shelf
|
core 18 box 12
|
|
410178
|
Moore Hall facility
|
B
|
B
|
4
|
6933.35
|
7182.95
|
Core Samples
|
On Shelf
|
end trims
|
|
500205
|
Moore Hall facility
|
B
|
A
|
5
|
6935.9
|
6938.5
|
Butt
|
On Shelf
|
core 18 box 13
|
|
500206
|
Moore Hall facility
|
B
|
A
|
5
|
6938.5
|
6940.8
|
Butt
|
On Shelf
|
core 18 box 14
|
|
500665
|
Moore Hall facility
|
A
|
A
|
4
|
6940
|
6949
|
Slabbed
|
On Shelf
|
|
|
500207
|
Moore Hall facility
|
B
|
A
|
5
|
6940.8
|
6943.6
|
Butt
|
On Shelf
|
core 18 box 15
|
|
400198
|
North Lawrence facility
|
44
|
4
|
2
|
6943.5
|
6958.6
|
Slabbed
|
On Shelf
|
|
|
500208
|
Moore Hall facility
|
B
|
A
|
5
|
6943.6
|
6946.6
|
Butt
|
On Shelf
|
core 18 box 16
|
|
500209
|
Moore Hall facility
|
B
|
A
|
5
|
6946.6
|
6949.3
|
Butt
|
On Shelf
|
core 18 box 17
|
|
500666
|
Moore Hall facility
|
A
|
A
|
4
|
6949
|
6958
|
Slabbed
|
On Shelf
|
|
|
500210
|
Moore Hall facility
|
B
|
A
|
5
|
6949.3
|
6951.8
|
Butt
|
On Shelf
|
core 18 box 18
|
|
500211
|
Moore Hall facility
|
B
|
A
|
5
|
6951.8
|
6954.6
|
Butt
|
On Shelf
|
core 18 box 19
|
|
500212
|
Moore Hall facility
|
B
|
A
|
4
|
6954.6
|
6957.4
|
Butt
|
On Shelf
|
core 18 box 20
|
|
500213
|
Moore Hall facility
|
B
|
A
|
4
|
6957.4
|
6960.2
|
Butt
|
On Shelf
|
core 18 box 21
|
|
500667
|
Moore Hall facility
|
A
|
A
|
3
|
6958
|
6964
|
Slabbed
|
On Shelf
|
|
|
400199
|
North Lawrence facility
|
44
|
4
|
2
|
6959
|
6978
|
Slabbed
|
On Shelf
|
|
|
500214
|
Moore Hall facility
|
B
|
A
|
4
|
6960.2
|
6962.5
|
Butt
|
On Shelf
|
core 18 box 22
|
|
500215
|
Moore Hall facility
|
B
|
A
|
4
|
6962.5
|
6964
|
Butt
|
On Shelf
|
core 18 box 23
|
|
500668
|
Moore Hall facility
|
A
|
A
|
3
|
6964
|
6973
|
Slabbed
|
On Shelf
|
|
|
500216
|
Moore Hall facility
|
B
|
A
|
4
|
6964
|
6966.6
|
Butt
|
On Shelf
|
core 19 box 1
|
|
500217
|
Moore Hall facility
|
B
|
A
|
4
|
6966.6
|
6969.45
|
Butt
|
On Shelf
|
core 19 box 2
|
|
500218
|
Moore Hall facility
|
B
|
A
|
4
|
6969.5
|
6972.3
|
Butt
|
On Shelf
|
core 19 box 3
|
|
500219
|
Moore Hall facility
|
B
|
A
|
4
|
6972.3
|
6974.7
|
Butt
|
On Shelf
|
core 19 box 4
|
|
500669
|
Moore Hall facility
|
A
|
A
|
3
|
6973
|
6982
|
Slabbed
|
On Shelf
|
|
|
500220
|
Moore Hall facility
|
B
|
A
|
4
|
6974.7
|
6977.5
|
Butt
|
On Shelf
|
core 19 box 5
|
|
500221
|
Moore Hall facility
|
B
|
A
|
4
|
6977.5
|
6980.4
|
Butt
|
On Shelf
|
core 19 box 6
|
|
500222
|
Moore Hall facility
|
B
|
A
|
4
|
6980.4
|
6982.95
|
Butt
|
On Shelf
|
core 19 box 7
|
|
500670
|
Moore Hall facility
|
A
|
A
|
3
|
6982
|
6989
|
Slabbed
|
On Shelf
|
|
|
500311
|
Moore Hall facility
|
B
|
A
|
4
|
6982.95
|
6985.75
|
Butt
|
On Shelf
|
core 19 box 8
|
|
500312
|
Moore Hall facility
|
B
|
A
|
4
|
6985.8
|
6987.7
|
Butt
|
On Shelf
|
core 19 box 9
|
|
500313
|
Moore Hall facility
|
B
|
A
|
4
|
6987.7
|
6989
|
Butt
|
On Shelf
|
core 19 box 10
|
|
500314
|
Moore Hall facility
|
B
|
A
|
4
|
7090
|
7092.9
|
Butt
|
On Shelf
|
core 20 box 1
|
|
500671
|
Moore Hall facility
|
A
|
A
|
3
|
7090
|
7099
|
Slabbed
|
On Shelf
|
|
|
500315
|
Moore Hall facility
|
B
|
A
|
4
|
7092.9
|
7095.5
|
Butt
|
On Shelf
|
core 20 box 2
|
|
500316
|
Moore Hall facility
|
B
|
A
|
4
|
7095.5
|
7098.38
|
Butt
|
On Shelf
|
core 20 box 3
|
|
500317
|
Moore Hall facility
|
B
|
A
|
4
|
7098.4
|
7101.2
|
Butt
|
On Shelf
|
core 20 box 4
|
|
500672
|
Moore Hall facility
|
A
|
A
|
3
|
7099
|
7108
|
Slabbed
|
On Shelf
|
|
|
500318
|
Moore Hall facility
|
B
|
A
|
4
|
7101.2
|
7103.8
|
Butt
|
On Shelf
|
core 20 box 5
|
|
500319
|
Moore Hall facility
|
B
|
A
|
4
|
7103.8
|
7106.5
|
Butt
|
On Shelf
|
core 20 box 6
|
|
400201
|
North Lawrence facility
|
44
|
4
|
2
|
7105
|
7123
|
Slabbed
|
On Shelf
|
|
|
500320
|
Moore Hall facility
|
B
|
A
|
4
|
7106.5
|
7109.2
|
Butt
|
On Shelf
|
core 20 box 7
|
|
500673
|
Moore Hall facility
|
A
|
A
|
3
|
7108
|
7117
|
Slabbed
|
On Shelf
|
|
|
500321
|
Moore Hall facility
|
B
|
A
|
4
|
7109.2
|
7111.5
|
Butt
|
On Shelf
|
core 20 box 8
|
|
500322
|
Moore Hall facility
|
B
|
A
|
4
|
7111.5
|
7114.3
|
Butt
|
On Shelf
|
core 20 box 9
|
|
500323
|
Moore Hall facility
|
B
|
A
|
4
|
7114.3
|
7116.6
|
Butt
|
On Shelf
|
core 20 box 10
|
|
500324
|
Moore Hall facility
|
B
|
A
|
4
|
7116.6
|
7119.4
|
Butt
|
On Shelf
|
core 20 box 11
|
|
500674
|
Moore Hall facility
|
A
|
A
|
3
|
7117
|
7126
|
Slabbed
|
On Shelf
|
|
|
500325
|
Moore Hall facility
|
B
|
A
|
4
|
7119.4
|
7122.1
|
Butt
|
On Shelf
|
core 20 box 12
|
|
500326
|
Moore Hall facility
|
B
|
A
|
4
|
7122.1
|
7124.9
|
Butt
|
On Shelf
|
core 20 box 13
|
|
500327
|
Moore Hall facility
|
B
|
A
|
4
|
7124.8
|
7127.85
|
Butt
|
On Shelf
|
core 20 box 14
|
|
500675
|
Moore Hall facility
|
A
|
A
|
3
|
7126
|
7135
|
Slabbed
|
On Shelf
|
|
|
400202
|
North Lawrence facility
|
44
|
4
|
2
|
7126.1
|
7139.05
|
Slabbed
|
On Shelf
|
|
|
500328
|
Moore Hall facility
|
B
|
A
|
4
|
7127.5
|
7130.25
|
Butt
|
On Shelf
|
core 20 box 15
|
|
500329
|
Moore Hall facility
|
B
|
A
|
4
|
7130.2
|
7132.8
|
Butt
|
On Shelf
|
core 20 box 16
|
|
500330
|
Moore Hall facility
|
B
|
A
|
4
|
7132.9
|
7135.25
|
Butt
|
On Shelf
|
core 20 box 17
|
|
500676
|
Moore Hall facility
|
A
|
A
|
3
|
7135
|
7144
|
Slabbed
|
On Shelf
|
|
|
500331
|
Moore Hall facility
|
B
|
A
|
4
|
7135.6
|
7137.7
|
Butt
|
On Shelf
|
core 20 box 18
|
|
500332
|
Moore Hall facility
|
B
|
A
|
4
|
7138.3
|
7140
|
Butt
|
On Shelf
|
core 20 box 19
|
|
400203
|
North Lawrence facility
|
44
|
4
|
2
|
7139.65
|
7161.3
|
Slabbed
|
On Shelf
|
|
|
500333
|
Moore Hall facility
|
B
|
A
|
4
|
7141
|
7143.35
|
Butt
|
On Shelf
|
core 20 box 20
|
|
500334
|
Moore Hall facility
|
B
|
A
|
4
|
7143.7
|
7146.2
|
Butt
|
On Shelf
|
core 20 box 21
|
|
500677
|
Moore Hall facility
|
A
|
A
|
3
|
7144
|
7150
|
Slabbed
|
On Shelf
|
|
|
500335
|
Moore Hall facility
|
B
|
A
|
4
|
7146.4
|
7148.9
|
Butt
|
On Shelf
|
core 20 box 22
|
|
500336
|
Moore Hall facility
|
B
|
A
|
4
|
7149.1
|
7150
|
Butt
|
On Shelf
|
core 20 box 23
|
|
500337
|
Moore Hall facility
|
B
|
B
|
7
|
7150
|
7152.5
|
Butt
|
On Shelf
|
core 21 box 1
|
|
500678
|
Moore Hall facility
|
A
|
A
|
3
|
7150
|
7159
|
Slabbed
|
On Shelf
|
|
|
500338
|
Moore Hall facility
|
B
|
A
|
4
|
7152.5
|
7155.3
|
Butt
|
On Shelf
|
core 21 box 2
|
|
500339
|
Moore Hall facility
|
B
|
A
|
4
|
7155.3
|
7158
|
Butt
|
On Shelf
|
core 21 box 3
|
|
500340
|
Moore Hall facility
|
B
|
B
|
4
|
7158
|
7160.5
|
Butt
|
On Shelf
|
core 21 box 4
|
|
500679
|
Moore Hall facility
|
A
|
A
|
3
|
7159
|
7168
|
Slabbed
|
On Shelf
|
|
|
500341
|
Moore Hall facility
|
B
|
B
|
4
|
7160.5
|
7162.9
|
Butt
|
On Shelf
|
core 21 box 5
|
|
400204
|
North Lawrence facility
|
44
|
4
|
2
|
7162.25
|
7173.15
|
Slabbed
|
On Shelf
|
|
|
500342
|
Moore Hall facility
|
B
|
B
|
4
|
7162.9
|
7165.45
|
Butt
|
On Shelf
|
core 21 box 6
|
|
500343
|
Moore Hall facility
|
B
|
B
|
4
|
7165.5
|
7168
|
Butt
|
On Shelf
|
core 21 box 7
|
|
500344
|
Moore Hall facility
|
B
|
B
|
4
|
7168
|
7170.7
|
Butt
|
On Shelf
|
core 21 box 8
|
|
500680
|
Moore Hall facility
|
A
|
A
|
3
|
7168
|
7177
|
Slabbed
|
On Shelf
|
|
|
500345
|
Moore Hall facility
|
B
|
B
|
4
|
7170.7
|
7173.3
|
Butt
|
On Shelf
|
core 21 box 9
|
|
400205
|
North Lawrence facility
|
44
|
4
|
2
|
7173.15
|
7182.75
|
Slabbed
|
On Shelf
|
|
|
500346
|
Moore Hall facility
|
B
|
B
|
4
|
7173.3
|
7175.8
|
Butt
|
On Shelf
|
core 21 box 10
|
|
500347
|
Moore Hall facility
|
B
|
B
|
4
|
7175.8
|
7178
|
Butt
|
On Shelf
|
core 21 box 11
|
|
500681
|
Moore Hall facility
|
A
|
A
|
3
|
7177
|
7178
|
Slabbed
|
On Shelf
|
|
|
500348
|
Moore Hall facility
|
B
|
A
|
4
|
7178
|
7181
|
Butt
|
On Shelf
|
core 22 box 1
|
|
500682
|
Moore Hall facility
|
A
|
A
|
3
|
7178
|
7187
|
Slabbed
|
On Shelf
|
|
|
500349
|
Moore Hall facility
|
B
|
A
|
4
|
7181
|
7183.7
|
Butt
|
On Shelf
|
core 22 box 2
|
|
500350
|
Moore Hall facility
|
B
|
A
|
4
|
7183.7
|
7186.76
|
Butt
|
On Shelf
|
core 22 box 3
|
|
400206
|
North Lawrence facility
|
44
|
4
|
2
|
7185.15
|
7202
|
Slabbed
|
On Shelf
|
|
|
500351
|
Moore Hall facility
|
B
|
A
|
4
|
7186.8
|
7189.5
|
Butt
|
On Shelf
|
core 22 box 4
|
|
500683
|
Moore Hall facility
|
A
|
A
|
3
|
7187
|
7196
|
Slabbed
|
On Shelf
|
|
|
500352
|
Moore Hall facility
|
B
|
A
|
4
|
7189.5
|
7192.4
|
Butt
|
On Shelf
|
core 22 box 5
|
|
410177
|
Moore Hall facility
|
B
|
B
|
4
|
7190.7
|
7531.7
|
Core Samples
|
On Shelf
|
end trims
|
|
500353
|
Moore Hall facility
|
B
|
A
|
4
|
7192.4
|
7195
|
Butt
|
On Shelf
|
core 22 box 6
|
|
500354
|
Moore Hall facility
|
B
|
A
|
4
|
7195
|
7197
|
Butt
|
On Shelf
|
core 22 box 7
|
|
500684
|
Moore Hall facility
|
A
|
A
|
3
|
7196
|
7205
|
Slabbed
|
On Shelf
|
|
|
500355
|
Moore Hall facility
|
B
|
A
|
4
|
7197
|
7200
|
Butt
|
On Shelf
|
core 22 box 8
|
|
500356
|
Moore Hall facility
|
B
|
A
|
4
|
7200
|
7202.9
|
Butt
|
On Shelf
|
core 22 box 9
|
|
500357
|
Moore Hall facility
|
B
|
A
|
4
|
7202.9
|
7205.7
|
Butt
|
On Shelf
|
core 22 box 10
|
|
400207
|
North Lawrence facility
|
44
|
4
|
2
|
7203.4
|
7211.7
|
Slabbed
|
On Shelf
|
|
|
500685
|
Moore Hall facility
|
A
|
A
|
3
|
7205
|
7214
|
Slabbed
|
On Shelf
|
|
|
500358
|
Moore Hall facility
|
B
|
A
|
4
|
7205.7
|
7208.4
|
Butt
|
On Shelf
|
core 22 box 11
|
|
500359
|
Moore Hall facility
|
B
|
A
|
4
|
7208.4
|
7211.3
|
Butt
|
On Shelf
|
core 22 box 12
|
|
500360
|
Moore Hall facility
|
B
|
A
|
4
|
7211.3
|
7214
|
Butt
|
On Shelf
|
core 22 box 13
|
|
400208
|
North Lawrence facility
|
44
|
4
|
2
|
7212.75
|
7220.45
|
Slabbed
|
On Shelf
|
|
|
500361
|
Moore Hall facility
|
B
|
A
|
4
|
7214
|
7216.6
|
Butt
|
On Shelf
|
core 22 box 14
|
|
500686
|
Moore Hall facility
|
A
|
A
|
3
|
7214
|
7223
|
Slabbed
|
On Shelf
|
|
|
500362
|
Moore Hall facility
|
B
|
A
|
4
|
7216.6
|
7219.5
|
Butt
|
On Shelf
|
core 22 box 15
|
|
500363
|
Moore Hall facility
|
B
|
B
|
4
|
7219.5
|
7222
|
Butt
|
On Shelf
|
core 22 box 16
|
|
500364
|
Moore Hall facility
|
B
|
B
|
4
|
7222
|
7224.75
|
Butt
|
On Shelf
|
core 22 box 17
|
|
400209
|
North Lawrence facility
|
44
|
4
|
2
|
7222.45
|
7254.05
|
Slabbed
|
On Shelf
|
|
|
500687
|
Moore Hall facility
|
A
|
A
|
3
|
7223
|
7232
|
Slabbed
|
On Shelf
|
|
|
500365
|
Moore Hall facility
|
B
|
B
|
4
|
7224.8
|
7227.3
|
Butt
|
On Shelf
|
core 22 box 18
|
|
500366
|
Moore Hall facility
|
B
|
B
|
4
|
7227.3
|
7230
|
Butt
|
On Shelf
|
core 22 box 19
|
|
500367
|
Moore Hall facility
|
B
|
B
|
4
|
7230
|
7232.5
|
Butt
|
On Shelf
|
core 22 box 20
|
|
500688
|
Moore Hall facility
|
A
|
A
|
3
|
7232
|
7237
|
Slabbed
|
On Shelf
|
|
|
500368
|
Moore Hall facility
|
B
|
B
|
4
|
7232.5
|
7235
|
Butt
|
On Shelf
|
core 22 box 21
|
|
500372
|
Moore Hall facility
|
B
|
B
|
4
|
7235
|
7237
|
Butt
|
On Shelf
|
core 22 box 22
|
|
500689
|
Moore Hall facility
|
A
|
A
|
3
|
7257
|
7266
|
Slabbed
|
On Shelf
|
|
|
500370
|
Moore Hall facility
|
B
|
B
|
7
|
7257
|
7259.5
|
Butt
|
On Shelf
|
core 23 box 1
|
|
400210
|
North Lawrence facility
|
44
|
4
|
2
|
7257
|
7266.85
|
Slabbed
|
On Shelf
|
|
|
500371
|
Moore Hall facility
|
B
|
B
|
4
|
7259.5
|
7262
|
Butt
|
On Shelf
|
core 23 box 2
|
|
500369
|
Moore Hall facility
|
B
|
A
|
4
|
7262.2
|
7265.2
|
Butt
|
On Shelf
|
core 23 box 3
|
|
500223
|
Moore Hall facility
|
B
|
A
|
4
|
7265.2
|
7267.85
|
Butt
|
On Shelf
|
core 23 box 4
|
|
500690
|
Moore Hall facility
|
A
|
A
|
3
|
7266
|
7271
|
Slabbed
|
On Shelf
|
|
|
400211
|
North Lawrence facility
|
44
|
4
|
2
|
7267.1
|
7349.85
|
Slabbed
|
On Shelf
|
|
|
500224
|
Moore Hall facility
|
B
|
A
|
4
|
7267.9
|
7271
|
Butt
|
On Shelf
|
core 23 box 5
|
|
500225
|
Moore Hall facility
|
B
|
A
|
4
|
7334
|
7336.95
|
Butt
|
On Shelf
|
core 24 box 23
|
|
500691
|
Moore Hall facility
|
A
|
A
|
3
|
7334
|
7343
|
Slabbed
|
On Shelf
|
|
|
500226
|
Moore Hall facility
|
B
|
A
|
4
|
7336.95
|
7339.8
|
Butt
|
On Shelf
|
core 24 box 22
|
|
500227
|
Moore Hall facility
|
B
|
A
|
4
|
7339.8
|
7342.15
|
Butt
|
On Shelf
|
core 24 box 21
|
|
500228
|
Moore Hall facility
|
B
|
B
|
7
|
7342.2
|
7345
|
Butt
|
On Shelf
|
core 24 box 20
|
|
500692
|
Moore Hall facility
|
A
|
A
|
3
|
7343
|
7352
|
Slabbed
|
On Shelf
|
|
|
500229
|
Moore Hall facility
|
B
|
B
|
7
|
7345
|
7347.7
|
Butt
|
On Shelf
|
core 24 box 19
|
|
500230
|
Moore Hall facility
|
B
|
B
|
7
|
7347.7
|
7350.3
|
Butt
|
On Shelf
|
core 24 box 18
|
|
500231
|
Moore Hall facility
|
B
|
B
|
7
|
7350.3
|
7352.7
|
Butt
|
On Shelf
|
core 24 box 17
|
|
400212
|
North Lawrence facility
|
44
|
4
|
2
|
7350.9
|
7369.15
|
Slabbed
|
On Shelf
|
|
|
500693
|
Moore Hall facility
|
A
|
A
|
3
|
7352
|
7361
|
Slabbed
|
On Shelf
|
|
|
500232
|
Moore Hall facility
|
B
|
B
|
7
|
7352.7
|
7355.45
|
Butt
|
On Shelf
|
core 24 box 16
|
|
500233
|
Moore Hall facility
|
B
|
B
|
7
|
7355.5
|
7358.2
|
Butt
|
On Shelf
|
core 24 box 15
|
|
500234
|
Moore Hall facility
|
B
|
B
|
7
|
7358.2
|
7360.5
|
Butt
|
On Shelf
|
core 24 box 14
|
|
500235
|
Moore Hall facility
|
B
|
B
|
7
|
7360.5
|
7363.1
|
Butt
|
On Shelf
|
core 24 box 13
|
|
500694
|
Moore Hall facility
|
A
|
A
|
3
|
7361
|
7370
|
Slabbed
|
On Shelf
|
|
|
500236
|
Moore Hall facility
|
B
|
B
|
7
|
7363.1
|
7365.7
|
Butt
|
On Shelf
|
core 24 box 12
|
|
500243
|
Moore Hall facility
|
B
|
B
|
7
|
7365.7
|
7368.2
|
Butt
|
On Shelf
|
core 24 box 11
|
|
500237
|
Moore Hall facility
|
B
|
B
|
7
|
7365.7
|
7368.3
|
Butt
|
On Shelf
|
core 24 box 10
|
|
500238
|
Moore Hall facility
|
B
|
B
|
7
|
7368.3
|
7371.2
|
Butt
|
On Shelf
|
core 24 box 9
|
|
400213
|
North Lawrence facility
|
44
|
4
|
2
|
7369.95
|
7414.85
|
Slabbed
|
On Shelf
|
|
|
500695
|
Moore Hall facility
|
A
|
A
|
3
|
7370
|
7379
|
Slabbed
|
On Shelf
|
|
|
500239
|
Moore Hall facility
|
B
|
B
|
7
|
7371.2
|
7373.9
|
Butt
|
On Shelf
|
core 24 box 8
|
|
500240
|
Moore Hall facility
|
B
|
B
|
7
|
7373.9
|
7376.6
|
Butt
|
On Shelf
|
core 24 box 7
|
|
500696
|
Moore Hall facility
|
A
|
A
|
3
|
7379
|
7388
|
Slabbed
|
On Shelf
|
|
|
500241
|
Moore Hall facility
|
B
|
B
|
7
|
7379.1
|
7381.4
|
Butt
|
On Shelf
|
core 24 box 6
|
|
500242
|
Moore Hall facility
|
B
|
B
|
7
|
7379.9
|
7381.6
|
Butt
|
On Shelf
|
core 24 box 5
|
|
500244
|
Moore Hall facility
|
B
|
B
|
7
|
7383.9
|
7386.4
|
Butt
|
On Shelf
|
core 24 box 4
|
|
500245
|
Moore Hall facility
|
B
|
B
|
7
|
7386.4
|
7389.1
|
Butt
|
On Shelf
|
core 24 box 3
|
|
500697
|
Moore Hall facility
|
A
|
A
|
3
|
7388
|
7394
|
Slabbed
|
On Shelf
|
|
|
500246
|
Moore Hall facility
|
B
|
B
|
7
|
7389.1
|
7391.8
|
Butt
|
On Shelf
|
core 24 box 2
|
|
500247
|
Moore Hall facility
|
B
|
B
|
7
|
7391.8
|
7394.6
|
Butt
|
On Shelf
|
core 24 box 1
|
|
500698
|
Moore Hall facility
|
A
|
A
|
3
|
7394
|
7403
|
Slabbed
|
On Shelf
|
|
|
500248
|
Moore Hall facility
|
B
|
B
|
7
|
7394.6
|
7396.7
|
Butt
|
On Shelf
|
core 25 box 1
|
|
500249
|
Moore Hall facility
|
B
|
B
|
7
|
7396.7
|
7399.25
|
Butt
|
On Shelf
|
core 25 box 2
|
|
500250
|
Moore Hall facility
|
B
|
B
|
7
|
7399.3
|
7401.6
|
Butt
|
On Shelf
|
core 25 box 3
|
|
500251
|
Moore Hall facility
|
B
|
B
|
7
|
7401.6
|
7404.5
|
Butt
|
On Shelf
|
core 25 box 4
|
|
500699
|
Moore Hall facility
|
A
|
A
|
3
|
7403
|
7412
|
Slabbed
|
On Shelf
|
|
|
500252
|
Moore Hall facility
|
B
|
B
|
7
|
7404.5
|
7406.85
|
Butt
|
On Shelf
|
core 25 box 5
|
|
500253
|
Moore Hall facility
|
B
|
B
|
7
|
7406.9
|
7409.55
|
Butt
|
On Shelf
|
core 25 box 6
|
|
500254
|
Moore Hall facility
|
B
|
B
|
7
|
7409.6
|
7412.4
|
Butt
|
On Shelf
|
core 25 box 7
|
|
500700
|
Moore Hall facility
|
A
|
A
|
3
|
7412
|
7421
|
Slabbed
|
On Shelf
|
|
|
500255
|
Moore Hall facility
|
B
|
B
|
7
|
7412.4
|
7415.25
|
Butt
|
On Shelf
|
core 25 box 8
|
|
500256
|
Moore Hall facility
|
B
|
B
|
7
|
7415.3
|
7417.95
|
Butt
|
On Shelf
|
core 25 box 9
|
|
400214
|
North Lawrence facility
|
44
|
4
|
2
|
7417.85
|
7540.1
|
Slabbed
|
On Shelf
|
|
|
500257
|
Moore Hall facility
|
B
|
B
|
7
|
7418
|
7420.85
|
Butt
|
On Shelf
|
core 25 box 10
|
|
500258
|
Moore Hall facility
|
B
|
B
|
7
|
7420.9
|
7423.35
|
Butt
|
On Shelf
|
core 25 box 11
|
|
500701
|
Moore Hall facility
|
A
|
A
|
3
|
7421
|
7426
|
Slabbed
|
On Shelf
|
|
|
500259
|
Moore Hall facility
|
B
|
B
|
7
|
7423.4
|
7426
|
Butt
|
On Shelf
|
core 25 box 12
|
|
500260
|
Moore Hall facility
|
B
|
B
|
7
|
7426
|
7428
|
Butt
|
On Shelf
|
core 26 box 1
|
|
500702
|
Moore Hall facility
|
A
|
A
|
3
|
7426
|
7432.5
|
Slabbed
|
On Shelf
|
|
|
500261
|
Moore Hall facility
|
B
|
B
|
7
|
7428
|
7430.1
|
Butt
|
On Shelf
|
core 26 box 2
|
|
500262
|
Moore Hall facility
|
B
|
B
|
7
|
7430.1
|
7432.5
|
Butt
|
On Shelf
|
core 26 box 3
|
|
500263
|
Moore Hall facility
|
B
|
B
|
7
|
7530
|
7532.7
|
Butt
|
On Shelf
|
core 27 box 1
|
|
500703
|
Moore Hall facility
|
A
|
A
|
3
|
7530
|
7539
|
Slabbed
|
On Shelf
|
|
|
500264
|
Moore Hall facility
|
B
|
B
|
7
|
7532.7
|
7535.85
|
Butt
|
On Shelf
|
core 27 box 2
|
|
410180
|
Moore Hall facility
|
B
|
B
|
4
|
7534.3
|
7587.95
|
Core Samples
|
On Shelf
|
end trims
|
|
500265
|
Moore Hall facility
|
B
|
B
|
7
|
7535.9
|
7537.65
|
Butt
|
On Shelf
|
core 27 box 3
|
|
500266
|
Moore Hall facility
|
B
|
B
|
7
|
7537.7
|
7540.55
|
Butt
|
On Shelf
|
core 27 box 4
|
|
500704
|
Moore Hall facility
|
A
|
A
|
3
|
7539
|
7548
|
Slabbed
|
On Shelf
|
|
|
500267
|
Moore Hall facility
|
B
|
B
|
7
|
7540.6
|
7543.45
|
Butt
|
On Shelf
|
core 27 box 5
|
|
500268
|
Moore Hall facility
|
B
|
B
|
7
|
7543.5
|
7546.25
|
Butt
|
On Shelf
|
core 27 box 6
|
|
400215
|
North Lawrence facility
|
44
|
4
|
2
|
7543.7
|
7567.45
|
Slabbed
|
On Shelf
|
|
|
500269
|
Moore Hall facility
|
B
|
B
|
7
|
7546.3
|
7549
|
Butt
|
On Shelf
|
core 27 box 7
|
|
500705
|
Moore Hall facility
|
A
|
A
|
3
|
7548
|
7557
|
Slabbed
|
On Shelf
|
|
|
500270
|
Moore Hall facility
|
B
|
B
|
7
|
7549
|
7551.95
|
Butt
|
On Shelf
|
core 27 box 8
|
|
500271
|
Moore Hall facility
|
B
|
B
|
7
|
7552
|
7554.8
|
Butt
|
On Shelf
|
core 27 box 9
|
|
500272
|
Moore Hall facility
|
B
|
B
|
7
|
7554.8
|
7557.4
|
Butt
|
On Shelf
|
core 27 box 10
|
|
500706
|
Moore Hall facility
|
A
|
A
|
3
|
7557
|
7566
|
Slabbed
|
On Shelf
|
|
|
500273
|
Moore Hall facility
|
B
|
B
|
7
|
7557.4
|
7560
|
Butt
|
On Shelf
|
core 27 box 11
|
|
500274
|
Moore Hall facility
|
B
|
B
|
7
|
7560
|
7562.65
|
Butt
|
On Shelf
|
core 27 box 12
|
|
500275
|
Moore Hall facility
|
B
|
B
|
7
|
7562.7
|
7565.55
|
Butt
|
On Shelf
|
core 27 box 13
|
|
500276
|
Moore Hall facility
|
B
|
B
|
7
|
7565.6
|
7568.3
|
Butt
|
On Shelf
|
core 27 box 14
|
|
500707
|
Moore Hall facility
|
A
|
A
|
3
|
7566
|
7568.3
|
Slabbed
|
On Shelf
|
|
|
500708
|
Moore Hall facility
|
A
|
A
|
3
|
7568.3
|
7577
|
Slabbed
|
On Shelf
|
|
|
500277
|
Moore Hall facility
|
B
|
B
|
7
|
7568.3
|
7571.2
|
Butt
|
On Shelf
|
core 28 box 1
|
|
400216
|
North Lawrence facility
|
44
|
4
|
2
|
7569.6
|
7587.85
|
Slabbed
|
On Shelf
|
|
|
500278
|
Moore Hall facility
|
B
|
B
|
7
|
7571.2
|
7574
|
Butt
|
On Shelf
|
core 28 box 2
|
|
500279
|
Moore Hall facility
|
B
|
B
|
7
|
7574
|
7576.35
|
Butt
|
On Shelf
|
core 28 box 3
|
|
500280
|
Moore Hall facility
|
B
|
B
|
7
|
7576.4
|
7579.2
|
Butt
|
On Shelf
|
core 28 box 4
|
|
500709
|
Moore Hall facility
|
A
|
A
|
3
|
7577
|
7586
|
Slabbed
|
On Shelf
|
|
|
500281
|
Moore Hall facility
|
B
|
B
|
7
|
7579.2
|
7581.6
|
Butt
|
On Shelf
|
core 28 box 5
|
|
500282
|
Moore Hall facility
|
B
|
B
|
7
|
7581.6
|
7584
|
Butt
|
On Shelf
|
core 28 box 6
|
|
500283
|
Moore Hall facility
|
B
|
B
|
7
|
7584
|
7586.6
|
Butt
|
On Shelf
|
core 28 box 7
|
|
500710
|
Moore Hall facility
|
A
|
A
|
3
|
7586
|
7589.5
|
Slabbed
|
On Shelf
|
|
|
500284
|
Moore Hall facility
|
B
|
B
|
7
|
7586.6
|
7589.5
|
Butt
|
On Shelf
|
core 28 box 8
|
|
Tops Data
Formation (source name) | Top | Base | Source | Updated |
Topeka
|
3621 |
|
Geological Report |
Oct-05-2012 |
Heebner
|
3978 |
|
Geological Report |
Oct-05-2012 |
Lansing
|
4043 |
|
Geological Report |
Oct-05-2012 |
Lansing B
|
4090 |
|
Geological Report |
Oct-05-2012 |
Lansing D
|
4174 |
|
Geological Report |
Oct-05-2012 |
Lansing G
|
4333 |
|
Geological Report |
Oct-05-2012 |
Kansas CIty A
|
4551 |
|
Geological Report |
Oct-05-2012 |
Kansas City B
|
4596 |
|
Geological Report |
Oct-05-2012 |
Marmaton A
|
4700 |
|
Geological Report |
Oct-05-2012 |
Marmaton B
|
4732 |
|
Geological Report |
Oct-05-2012 |
Pawnee
|
4834 |
|
Geological Report |
Oct-05-2012 |
Ft. Scott
|
4875 |
|
Geological Report |
Oct-05-2012 |
Cherokee shale
|
4898 |
|
Geological Report |
Oct-05-2012 |
Basal Cherokee Porosity
|
5133 |
|
Geological Report |
Oct-05-2012 |
Upper Morrow Sand
|
5244 |
|
Geological Report |
Oct-05-2012 |
Chester formation
|
5476 |
|
Geological Report |
Oct-05-2012 |
Chester porosity
|
5556 |
|
Geological Report |
Oct-05-2012 |
St. Louis porosity
|
5665 |
|
Geological Report |
Oct-05-2012 |
Viola
|
6488 |
|
Geological Report |
Oct-05-2012 |
Simpson Shale
|
6690 |
|
Geological Report |
Oct-05-2012 |
Arbuckle
|
6711 |
|
ACO-1/Driller's Log |
Jul-25-2024 |
Precambrian
|
7602 |
|
Watney Marked Logs |
Jul-25-2024 |
DST Data
Oil Production Data
This well has been linked to an oil lease.
Images of core, thin sections, and SEM photos
View images for this well
Information from Outside Sources
Please note: The link below takes you away from the web site of the Kansas Geological Survey to the website of the Kansas Geological Society, a library in Wichita. The Survey can not help with information presented by the Walters Digital Library.
From Kansas Geological Society's Walters Digital Library
|