API: 15-033-20969
Operator: Thoroughbred Assoc., LLC Field: Bird Northeast Lease: Rietzke Well 1 |
Location: T32S R19W, Sec. 21, N2 NE NW
330 South, 2074 East, from NW corner Longitude: -99.3931937 Latitude: 37.2501253 County: Comanche Status: O&G |
Spud Date: 08/21/1998
Completion Date: 09/25/1998 Plugging Date: Total Depth: 6164 Form. at depth: ARBUCKLE GROUP Elevation: 1977 KB |
Test Number: 1 | Data Source: TRILOBITE |
Interval: 4451 to 4496
Formation tested: Lansing E&F | Date, Time: 08/27/1998; 05:28:21 |
Initial Hydro Pressure: PSI
First Initial Flow Pressure: PSI First Final Flow Pressure: PSI Initial Shut-in Pressure: PSI Second Initial Flow Pressure: PSI Second Final Flow Pressure: PSI Final Shut-in Pressure: PSI Final Hydro Pressure: PSI |
Tool Data Hole Size: 7.78 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: 240 ft. Drill Pipe Length: 4205 ft. |
IFP-strong blow gas to surface in 3min. FFP-gas to surface | |
Bottom Hole Temperature: 107 DEG F
Percent Porosity: Samples: gas sample bottle#88 Gas Recovery: Comments: | |
Recovery 270 of Total Fluid 240 of Fluid in Drill Collars 30 of Fluid in Drill Pipe 270 of gas cut mud 25%gas 75%mud | |
View Pressures | View Recovery Gas |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 2 | Data Source: TRILOBITE |
Interval: 4985 to 5090
Formation tested: miss | Date, Time: 08/29/1998; 09:33:46 |
Initial Hydro Pressure: PSI
First Initial Flow Pressure: PSI First Final Flow Pressure: PSI Initial Shut-in Pressure: PSI Second Initial Flow Pressure: PSI Second Final Flow Pressure: PSI Final Shut-in Pressure: PSI Final Hydro Pressure: PSI |
Tool Data Hole Size: 7.78 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: 240 ft. Drill Pipe Length: 4732 ft. |
IFP-strong blow gas to surface in 4min. FFP-gas to surface | |
Bottom Hole Temperature: 114 DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 390 of Total Fluid 240 of Fluid in Drill Collars 150 of Fluid in Drill Pipe 150 of gas cut mud 15%gas 85%mud 240 of gas cut mud 30%gas 70%mud | |
View Pressures | View Recovery Gas |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |