API: 15-077-21359
Operator: CLEARY EXPLORATION LLC Field: Wildcat Lease: Dorothy Brown Trust Well 1-31 |
Location: T33S R9W, Sec. 31, NE SE
1980 North, 660 West, from SE corner Longitude: -98.3318349 Latitude: 37.1286877 County: Harper Status: D&A |
Spud Date: 31-AUG-98
Completion Date: 10-SEP-98 Plugging Date: 10-SEP-98 Total Depth: 4592 Form. at depth: MISSISSIPPIAN Elevation: 1328 KB |
Test Number: 1 | Data Source: TRILOBITE |
Interval: 3787 to 3877
Formation tested: Stalnaker | Date, Time: 05-SEP-98; 18:05:09 |
Initial Hydro Pressure: PSI
First Initial Flow Pressure: PSI First Final Flow Pressure: PSI Initial Shut-in Pressure: PSI Second Initial Flow Pressure: PSI Second Final Flow Pressure: PSI Final Shut-in Pressure: PSI Final Hydro Pressure: PSI |
Tool Data Hole Size: 7.78 in. Drill Collar ID: in. Drill Pipe ID: 3.8 in. Drill Collar Length: ft. Drill Pipe Length: 3773 ft. |
Bottom Hole Temperature: 113 DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 120 of Total Fluid 120 of Fluid in Drill Pipe 120 of mud | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 2 | Data Source: TRILOBITE |
Interval: 3854 to 3877
Formation tested: stalnaker | Date, Time: 05-SEP-98; 22:18:11 |
Initial Hydro Pressure: PSI
First Initial Flow Pressure: PSI First Final Flow Pressure: PSI Initial Shut-in Pressure: PSI Second Initial Flow Pressure: PSI Second Final Flow Pressure: PSI Final Shut-in Pressure: PSI Final Hydro Pressure: PSI |
Tool Data Hole Size: 7.78 in. Drill Collar ID: in. Drill Pipe ID: 3.8 in. Drill Collar Length: ft. Drill Pipe Length: 3835 ft. |
IFP-weak building to a strong blow in2"" FFP-weak building to a strong blow in6"" | |
Bottom Hole Temperature: 118 DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 1320 of Total Fluid 1320 of Fluid in Drill Pipe 240 of muddy water 20%mud 80%water 1080 of water rw .04@ 67F 93000 of Salinity (PPM) | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 3 | Data Source: TRILOBITE |
Interval: 4536 to 4552
Formation tested: Miss. | Date, Time: 08-SEP-98; 17:52:24 |
Initial Hydro Pressure: 2295 PSI
First Initial Flow Pressure: 22 PSI First Final Flow Pressure: 33 PSI Initial Shut-in Pressure: 1635 PSI Second Initial Flow Pressure: 34 PSI Second Final Flow Pressure: 56 PSI Final Shut-in Pressure: 1676 PSI Final Hydro Pressure: 2334 PSI |
Tool Data Hole Size: 7.88 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: ft. Drill Pipe Length: 4520 ft. |
IF:Fair blow built to 7"" ISI:Bled down for 5 mins.No bb. FF:Weak blow FSI:Bled down for 10 mins.No bb. | |
Bottom Hole Temperature: 128 DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 90 of Total Fluid 90 of Fluid in Drill Pipe 30 of SOCM 10%oil 90%mud 60 of MCOW 10%oil 60%water 30%mud 150 of Gas in pipe 62000 of Salinity (PPM) | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |