Drill Stem Tests Database
Specific Well--15-081-21205
API: 15-081-21205
Operator:
Field: Eubank
Lease: MLP FEIERTAG
Well 1-32
Location: T29S R34W, Sec. 32, W2 SE NE
2029 South, 990 West, from NE corner
Longitude: -101.056212
Latitude: 37.483985
County: Haskell
Status: D&A
Spud Date: 18-MAY-98
Completion Date: 01-JUN-98
Plugging Date: 01-JUN-98
Total Depth: 5811
Form. at depth: MISSISSIPPIAN
Elevation: 3010 KB
Test Number: Data Source: TRILOBITE
Interval: to
Formation tested:
Date, Time: 30-MAY-98; 18:13:50
  Tool Data
Hole Size: in.
Drill Collar ID: in.
Drill Pipe ID: in.
Drill Collar Length: ft.
Drill Pipe Length: ft.
Bottom Hole Temperature: DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 3 Data Source: TRILOBITE
Interval: 5542 to 5600
Formation tested: Chester
Date, Time: 31-MAY-98; 12:51:08
Initial Hydro Pressure: 2794 PSI
First Initial Flow Pressure: 63 PSI
First Final Flow Pressure: 108 PSI
Initial Shut-in Pressure: 1712 PSI
Second Initial Flow Pressure: 109 PSI
Second Final Flow Pressure: 129 PSI
Final Shut-in Pressure: 1614 PSI
Final Hydro Pressure: 2693 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 207 ft.
Drill Pipe Length: 5535 ft.
1st opening weak blow built to 2.5 in 2nd opening very weak surface blow for 3 min then no blow
Bottom Hole Temperature: 125 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
180 of Total Fluid
180 of Fluid in Drill Collars
180 of 100% drlg. mud
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.