Drill Stem Tests Database
Specific Well--15-191-22326
API: 15-191-22326
Operator: NOBLE PETROLEUM
Field: Wildcat
Lease: Mason
Well 1
Location: T34S R1W, Sec. 14, NW NW SW SE
1262 North, 2402 West, from SE corner
Longitude: -97.390844
Latitude: 37.0894743
County: Sumner
Status: OIL
Spud Date: 10/28/1998
Completion Date: 11/15/1998
Plugging Date:
Total Depth: 4450
Form. at depth: ARBUCKLE
Elevation: 1173 KB
Discovery well for Mirt East field.

Download DST Test Data

Test Number: 1 Data Source: TRILOBITE
Interval: 3168 to 3194
Formation tested: Layton sd.
Date, Time: 11/07/1998; 21:38:57
Initial Hydro Pressure: 1625 PSI
First Initial Flow Pressure: 18 PSI
First Final Flow Pressure: 22 PSI
Initial Shut-in Pressure: 1249 PSI
Second Initial Flow Pressure: 33 PSI
Second Final Flow Pressure: 48 PSI
Final Shut-in Pressure: 1244 PSI
Final Hydro Pressure: 1516 PSI
Tool Data
Hole Size: 7.88 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: ft.
Drill Pipe Length: 3166 ft.
IF:Weak blow built to 5""in H2O bucket. ISI:Bled down for 20 mins FF:Weak blow built to 4"" in H2O bucket. FSI:Bled down for 10 mins no bb.
Bottom Hole Temperature: 111 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
90 of Total Fluid
90 of Fluid in Drill Pipe
30 of WCM 30%water 70%mud trace of oil
60 of SMCW 80%water 20%mud
50000 of Salinity (PPM)
View Pressures No Recovery Gas data.
 
Test Number: 2 Data Source: TRILOBITE
Interval: 3395 to 3470
Formation tested: K C
Date, Time: 11/09/1998; 05:24:56
Initial Hydro Pressure: 1648 PSI
First Initial Flow Pressure: 28 PSI
First Final Flow Pressure: 24 PSI
Initial Shut-in Pressure: 599 PSI
Second Initial Flow Pressure: 24 PSI
Second Final Flow Pressure: 25 PSI
Final Shut-in Pressure: 649 PSI
Final Hydro Pressure: 1603 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: ft.
Drill Pipe Length: 3386 ft.
Initial Flow: Weak blow throughout 1/2"" to 1/4"" blow
Final Flow: No blow
Bottom Hole Temperature: 103 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
5 of Total Fluid
5 of Fluid in Drill Pipe
5 of mud
View Pressures No Recovery Gas data.
 
Test Number: 3 Data Source: TRILOBITE
Interval: 3881 to 3907
Formation tested: miss
Date, Time: 11/11/1998; 05:21:04
Initial Hydro Pressure: 1910 PSI
First Initial Flow Pressure: 98 PSI
First Final Flow Pressure: 171 PSI
Initial Shut-in Pressure: 1547 PSI
Second Initial Flow Pressure: 120 PSI
Second Final Flow Pressure: 137 PSI
Final Shut-in Pressure: 1503 PSI
Final Hydro Pressure: 1858 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: ft.
Drill Pipe Length: 3881 ft.
IFP-strong FFP-gas to surface
Bottom Hole Temperature: 114 DEG F
Percent Porosity:
Samples: gas sample two bottles
Gas Recovery:
Comments:
Recovery
150 of Total Fluid
150 of Fluid in Drill Pipe
30 of slightly oil&gas cut mud 5%gas 3%oil92%mud
60 of heavy oil cut gassy mud 15 gas 20 oil 65 mud
60 of muddy gassy oil 15%gas 45%oil 40%mud
View Pressures View Recovery Gas
 
Test Number: 4 Data Source: TRILOBITE
Interval: 4232 to 4276
Formation tested: simpson sd.
Date, Time: 11/13/1998; 09:52:43
Initial Hydro Pressure: 2091 PSI
First Initial Flow Pressure: 25 PSI
First Final Flow Pressure: 41 PSI
Initial Shut-in Pressure: 1640 PSI
Second Initial Flow Pressure: 48 PSI
Second Final Flow Pressure: 66 PSI
Final Shut-in Pressure: 1639 PSI
Final Hydro Pressure: 2077 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: ft.
Drill Pipe Length: 4229 ft.
IFP-weak building to a strong blow in 8"" FFP-strong blow throughout no blow back on shut-ins
Bottom Hole Temperature: 127 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
115 of Total Fluid
115 of Fluid in Drill Pipe
3600 of gas in pipe
55 of oil cut gassy mud 10%oil 35%gas 65%mud
60 of heavy oil cut gassy mud 17%oil 62%gas 21%mud
View Pressures No Recovery Gas data.
 
Test Number: 5 Data Source: TRILOBITE
Interval: 4276 to 4284
Formation tested: simpson sd
Date, Time: 11/13/1998; 23:18:18
Initial Hydro Pressure: 2102 PSI
First Initial Flow Pressure: 113 PSI
First Final Flow Pressure: 262 PSI
Initial Shut-in Pressure: 1634 PSI
Second Initial Flow Pressure: 295 PSI
Second Final Flow Pressure: 439 PSI
Final Shut-in Pressure: 1635 PSI
Final Hydro Pressure: 2031 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: ft.
Drill Pipe Length: 4260 ft.
IFP-strong blow gas to surface in 13min. had blow back on shut-in FFP-gas to surface had blow back on shut-in
Bottom Hole Temperature: 138 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
1050 of Total Fluid
1050 of Fluid in Drill Pipe
500 of clean oil
185 of muddy gassy oil 40% gas 53% oil 7%mud
370 of water rw .07 @ 70F
120000 of Salinity (PPM)
40 of Gravity (API)
View Pressures View Recovery Gas