Drill Stem Tests Database
Specific Well--15-119-20997
API: 15-119-20997
Operator: HRF Exploration & Production, Inc.
Field: Novinger
Lease: Powell Farms
Well 1
Location: T33S R30W, Sec. 22, N2 SE SE
990 North, 660 West, from SE corner
Longitude: -100.5641962
Latitude: 37.158032
County: Meade
Status: GAS-P&A
Spud Date: 17-FEB-99
Completion Date: 02-MAR-99
Plugging Date: 20-OCT-99
Total Depth: 6350
Form. at depth: ST LOUIS
Elevation: 11 KB
Test Number: 1 Data Source: TRILOBITE
Interval: 5150 to 5187
Formation tested: Upper Marmaton
Date, Time: 22-FEB-99; 12:33:20
Initial Hydro Pressure: 2550 PSI
First Initial Flow Pressure: 16 PSI
First Final Flow Pressure: 204 PSI
Initial Shut-in Pressure: 337 PSI
Second Initial Flow Pressure: 21 PSI
Second Final Flow Pressure: 42 PSI
Final Shut-in Pressure: 58 PSI
Final Hydro Pressure: 2464 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 244 ft.
Drill Pipe Length: 4903 ft.
Initial Flow: Weak surface blow
Final Flow: No blow
Bottom Hole Temperature: 111 DEG F
Percent Porosity:
Samples: no
Gas Recovery:
Comments:
Recovery
1 of Total Fluid
1 of Fluid in Drill Collars
1 of 100% Drilling mud
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 2 Data Source: TRILOBITE
Interval: 5267 to 5290
Formation tested: Nonvinger
Date, Time: 23-FEB-99; 12:08:51
Initial Hydro Pressure: 2645 PSI
First Initial Flow Pressure: 41 PSI
First Final Flow Pressure: 52 PSI
Initial Shut-in Pressure: 1580 PSI
Second Initial Flow Pressure: 56 PSI
Second Final Flow Pressure: 104 PSI
Final Shut-in Pressure: 1598 PSI
Final Hydro Pressure: 2582 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 244 ft.
Drill Pipe Length: 4998 ft.
Initial Flow: Slow building blow built to 6""
Final Flow: Weak blow built to 3.5""
Bottom Hole Temperature: 122 DEG F
Percent Porosity:
Samples: no
Gas Recovery:
Comments:
Recovery
135 of Total Fluid
135 of Fluid in Drill Collars
15 of Gassy - Slightly Oil Cut Water
120 of Muddy Water 75% Water - 25% Mud
75000 of Salinity (PPM)
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 3 Data Source: TRILOBITE
Interval: 5267 to 5290
Formation tested: Morrow
Date, Time: 25-FEB-99; 10:08:35
Initial Hydro Pressure: 2771 PSI
First Initial Flow Pressure: 111 PSI
First Final Flow Pressure: 223 PSI
Initial Shut-in Pressure: 64 PSI
Second Initial Flow Pressure: 15 PSI
Second Final Flow Pressure: 19 PSI
Final Shut-in Pressure: 32 PSI
Final Hydro Pressure: 2712 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 244 ft.
Drill Pipe Length: 5467 ft.
Initial Flow: Weak blow throughout
Final Flow: Weak blow built to .5"" died in 20 min.
Bottom Hole Temperature: 127 DEG F
Percent Porosity:
Samples: no
Gas Recovery:
Comments:
Recovery
2 of Total Fluid
2 of Fluid in Drill Collars
2 of 100% Drilling mud
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 4 Data Source: TRILOBITE
Interval: 5738 to 5930
Formation tested: Chester
Date, Time: 26-FEB-99; 13:35:50
Initial Hydro Pressure: 2744 PSI
First Initial Flow Pressure: 54 PSI
First Final Flow Pressure: 70 PSI
Initial Shut-in Pressure: 1300 PSI
Second Initial Flow Pressure: 41 PSI
Second Final Flow Pressure: 77 PSI
Final Shut-in Pressure: 1298 PSI
Final Hydro Pressure: 2756 PSI
Tool Data
Hole Size: 7.88 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 244 ft.
Drill Pipe Length: 5624 ft.
Initial Flow: Strong blow bottom of bucket in 1 min.
Final Flow: Strong blow bottom of bucket as soon as open tool gas to surface in 6 mins.
Bottom Hole Temperature: 129 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
130 of Total Fluid
130 of Fluid in Drill Collars
130 of Drilling mud
View Pressures View Recovery Gas
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 5 Data Source: TRILOBITE
Interval: 5994 to 6101
Formation tested: Lower Chester
Date, Time: 27-FEB-99; 16:12:28
Initial Hydro Pressure: 3083 PSI
First Initial Flow Pressure: 31 PSI
First Final Flow Pressure: 43 PSI
Initial Shut-in Pressure: 83 PSI
Second Initial Flow Pressure: 47 PSI
Second Final Flow Pressure: 52 PSI
Final Shut-in Pressure: 70 PSI
Final Hydro Pressure: 2923 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 244 ft.
Drill Pipe Length: 5812 ft.
Initial Flow: Weak blow built to .250""
Final Flow: Bubble then no blow
Bottom Hole Temperature: 131 DEG F
Percent Porosity:
Samples: NO
Gas Recovery:
Comments:
Recovery
20 of Total Fluid
20 of Fluid in Drill Collars
20 of 100% Drilling mud
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.