Drill Stem Tests Database
Specific Well--15-081-21172
API: 15-081-21172
Operator: Hugoton Energy Corp.
Field: Eubank East
Lease: MLP SANTALA
Well 2-26
Location: T29S R34W, Sec. 26, S2 SW NE
2380 South, 1909 West, from NE corner
Longitude: -101.0048241
Latitude: 37.4974355
County: Haskell
Status: O&G
Spud Date: 14-JAN-98
Completion Date: 04-FEB-98
Plugging Date:
Total Depth: 5590
Form. at depth: CHESTER
Elevation: 2979 KB
Test Number: 1 Data Source: TRILOBITE
Interval: 4617 to 4640
Formation tested: K.C.""B""
Date, Time: 19-JAN-98; 10:44:39
Initial Hydro Pressure: PSI
First Initial Flow Pressure: PSI
First Final Flow Pressure: PSI
Initial Shut-in Pressure: PSI
Second Initial Flow Pressure: PSI
Second Final Flow Pressure: PSI
Final Shut-in Pressure: PSI
Final Hydro Pressure: PSI
Tool Data
Hole Size: 7.8 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 180 ft.
Drill Pipe Length: 4437 ft.
IFP-Strong Blow gas to surface in 7min. FFP-STRONG bLOW GAS TO SURFACE
Bottom Hole Temperature: 109 DEG F
Percent Porosity: 20
Samples:
Gas Recovery:
Comments:
Recovery
690 of Total Fluid
180 of Fluid in Drill Collars
510 of Fluid in Drill Pipe
510 of Clean Oil
170 of M.G.O.15%gas 55%oil 30%mud
10 of water
61000 of Salinity (PPM)
32 of Gravity (API)
View Pressures View Recovery Gas
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: Data Source: TRILOBITE
Interval: to
Formation tested:
Date, Time: 20-JAN-98; 21:02:51
  Tool Data
Hole Size: in.
Drill Collar ID: in.
Drill Pipe ID: in.
Drill Collar Length: ft.
Drill Pipe Length: ft.
Bottom Hole Temperature: DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 3 Data Source: TRILOBITE
Interval: 5190 to 5304
Formation tested: Morrow
Date, Time: 22-JAN-98; 12:55:55
Initial Hydro Pressure: PSI
First Initial Flow Pressure: PSI
First Final Flow Pressure: PSI
Initial Shut-in Pressure: PSI
Second Initial Flow Pressure: PSI
Second Final Flow Pressure: PSI
Final Shut-in Pressure: PSI
Final Hydro Pressure: PSI
Tool Data
Hole Size: 7.8 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 180 ft.
Drill Pipe Length: 5010 ft.
IFP-weak building to a strong blow in 15 min. FFP-fair building to a strong blow in 8 min.
Bottom Hole Temperature: DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
80 of Total Fluid
80 of Fluid in Drill Collars
240 of gas in pipe
20 of mud
60 of sli.oil&gas cut mud
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 4 Data Source: TRILOBITE
Interval: 5300 to 5428
Formation tested: Chester
Date, Time: 23-JAN-98; 11:22:11
Initial Hydro Pressure: PSI
First Initial Flow Pressure: PSI
First Final Flow Pressure: PSI
Initial Shut-in Pressure: PSI
Second Initial Flow Pressure: PSI
Second Final Flow Pressure: PSI
Final Shut-in Pressure: PSI
Final Hydro Pressure: PSI
Tool Data
Hole Size: 7.8 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 180 ft.
Drill Pipe Length: 5120 ft.
IFP-Strong blow gas yo surface in 3min. FFP-Strong blow gas to surface
Bottom Hole Temperature: 118 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
190 of Total Fluid
180 of Fluid in Drill Collars
10 of Fluid in Drill Pipe
190 of gas cut mud
View Pressures View Recovery Gas
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.