Drill Stem Tests Database
Specific Well--15-101-21741
API: 15-101-21741
Operator: RHEEM RESOURCES
Field: Pendennis Northwest
Lease: GATES 'A'
Well 1
Location: T16S R27W, Sec. 18, SE SW NW
2883 North, 3989 West, from SE corner
Longitude: -100.3542974
Latitude: 38.6625672
County: Lane
Status: OIL-P&A
Spud Date: 04/18/1997
Completion Date: 05/30/1997
Plugging Date: 03/27/2003
Total Depth: 4560
Form. at depth: MISSISSIPPIAN
Elevation: 2652 KB

Download DST Test Data

Test Number: 1 Data Source: TRILOBITE
Interval: 3975 to 3994
Formation tested: Lansing KC ""E""
Date, Time: 04/24/1997; 02:25:50
Initial Hydro Pressure: 1879 PSI
First Initial Flow Pressure: 561 PSI
First Final Flow Pressure: 1075 PSI
Initial Shut-in Pressure: 1098 PSI
Second Initial Flow Pressure: 1082 PSI
Second Final Flow Pressure: 1101 PSI
Final Shut-in Pressure: 1103 PSI
Final Hydro Pressure: 1866 PSI
Tool Data
Hole Size: 7.88 in.
Drill Collar ID: in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: ft.
Drill Pipe Length: 3968 ft.
Initial Flow: Strong bottom of bucket in 30 sec Initial Shut-in: Bled off blow - no return
Final Flow: Weak - steady 3"" blow
Final Shut-in: No blow back
Bottom Hole Temperature: 123 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
2355 of Total Fluid
2355 of Fluid in Drill Pipe
2355 of Water
50000 of Salinity (PPM)
View Pressures No Recovery Gas data.
 
Test Number: 2 Data Source: TRILOBITE
Interval: 4055 to 4082
Formation tested: Lansing KC ""G-H""
Date, Time: 04/24/1997; 18:01:26
Initial Hydro Pressure: 1957 PSI
First Initial Flow Pressure: 16 PSI
First Final Flow Pressure: 22 PSI
Initial Shut-in Pressure: 981 PSI
Second Initial Flow Pressure: 27 PSI
Second Final Flow Pressure: 30 PSI
Final Shut-in Pressure: 842 PSI
Final Hydro Pressure: 1941 PSI
Tool Data
Hole Size: 7.88 in.
Drill Collar ID: in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: ft.
Drill Pipe Length: 4060 ft.
Intial Flow: Weak steady surface blow
Final Flow: No blow
Bottom Hole Temperature: 113 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
10 of Total Fluid
10 of Fluid in Drill Pipe
10 of Slight Oil Cut Mud
View Pressures No Recovery Gas data.
 
Test Number: 3 Data Source: TRILOBITE
Interval: 4088 to 4151
Formation tested: Lansing KC ""I-J""
Date, Time: 04/25/1997; 11:20:28
Initial Hydro Pressure: 2009 PSI
First Initial Flow Pressure: 20 PSI
First Final Flow Pressure: 21 PSI
Initial Shut-in Pressure: 74 PSI
Second Initial Flow Pressure: 21 PSI
Second Final Flow Pressure: 21 PSI
Final Shut-in Pressure: 42 PSI
Final Hydro Pressure: 1964 PSI
Tool Data
Hole Size: 7.88 in.
Drill Collar ID: in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: ft.
Drill Pipe Length: 4093 ft.
Initial Flow: Weak-Died in 15 min
Final Flow: No blow
Bottom Hole Temperature: 111 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
5 of Total Fluid
5 of Fluid in Drill Pipe
5 of Slight Oil Cut Mud w/ show free oil in tool
View Pressures No Recovery Gas data.
 
Test Number: 4 Data Source: TRILOBITE
Interval: 4145 to 4170
Formation tested: Lansing KS ""K""
Date, Time: 04/26/1997; 00:07:35
Initial Hydro Pressure: 2020 PSI
First Initial Flow Pressure: 22 PSI
First Final Flow Pressure: 51 PSI
Initial Shut-in Pressure: 770 PSI
Second Initial Flow Pressure: 61 PSI
Second Final Flow Pressure: 91 PSI
Final Shut-in Pressure: 736 PSI
Final Hydro Pressure: 1985 PSI
Tool Data
Hole Size: 7.88 in.
Drill Collar ID: in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: ft.
Drill Pipe Length: 4153 ft.
Initial Flow: Weak building to strong 14"" blow Initial Shut-in: Bled off blow-no return
Final Flow: Weak building to 8"" fair blow
Final Shut-in: Bled off blow - weak surface blow throughout
Bottom Hole Temperature: 118 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
134 of Total Fluid
134 of Fluid in Drill Pipe
10 of Clean Gassy Oil
62 of Gas & Oil Cut Mud
62 of Oil & Gas Cut Watery Mud 35%M
30000 of Salinity (PPM)
View Pressures No Recovery Gas data.
 
Test Number: 5 Data Source: TRILOBITE
Interval: 4184 to 4211
Formation tested: Lansing KC ""L""
Date, Time: 04/26/1997; 15:31:37
Initial Hydro Pressure: 2061 PSI
First Initial Flow Pressure: 19 PSI
First Final Flow Pressure: 20 PSI
Initial Shut-in Pressure: 58 PSI
Second Initial Flow Pressure: 19 PSI
Second Final Flow Pressure: 19 PSI
Final Shut-in Pressure: 35 PSI
Final Hydro Pressure: 2021 PSI
Tool Data
Hole Size: 7.88 in.
Drill Collar ID: in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: ft.
Drill Pipe Length: 4184 ft.
Initial Flow: Weak -Died in 20 min
Final Flow: No blow
Bottom Hole Temperature: 114 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
5 of Total Fluid
5 of Fluid in Drill Pipe
5 of Drilling mud
View Pressures No Recovery Gas data.