API: 15-119-20971
Operator: Cross Bar Petroleum, Inc. Field: Plains Lease: Roehr Well 1-17 |
Location: T32S R30W, Sec. 17, SW
1320 North, 1320 East, from SW corner Longitude: -100.6120029 Latitude: 37.2606221 County: Meade Status: D&A |
Spud Date: 04-NOV-96
Completion Date: 17-NOV-96 Plugging Date: 17-NOV-96 Total Depth: 5800 Form. at depth: CHESTER Elevation: 2774 KB |
Test Number: 1 | Data Source: TRILOBITE |
Interval: 5581 to 5624
Formation tested: | Date, Time: 13-NOV-96; 23:47:19 |
Initial Hydro Pressure: PSI
First Initial Flow Pressure: PSI First Final Flow Pressure: PSI Initial Shut-in Pressure: PSI Second Initial Flow Pressure: PSI Second Final Flow Pressure: PSI Final Shut-in Pressure: PSI Final Hydro Pressure: PSI |
Tool Data Hole Size: in. Drill Collar ID: in. Drill Pipe ID: in. Drill Collar Length: ft. Drill Pipe Length: ft. |
Bottom Hole Temperature: DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 2 | Data Source: TRILOBITE |
Interval: 5610 to 5634
Formation tested: Morrow | Date, Time: 14-NOV-96; 19:19:31 |
Initial Hydro Pressure: 2732 PSI
First Initial Flow Pressure: 42 PSI First Final Flow Pressure: 124 PSI Initial Shut-in Pressure: 1424 PSI Second Initial Flow Pressure: 38 PSI Second Final Flow Pressure: 185 PSI Final Shut-in Pressure: 1419 PSI Final Hydro Pressure: 2603 PSI |
Tool Data Hole Size: 7.88 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: ft. Drill Pipe Length: 5305 ft. |
Initial Flow - Strong blow - bottom of bucket in 2 min. Initial Shut-in - Bled off 2"" - no blow back Final Flow - Fair blow - built to bottom of bucket in 16 min. Final Shut-in - Bled off 2"" - no blow back |
|
Bottom Hole Temperature: 126 DEG F
Percent Porosity: Samples: NO Gas Recovery: Comments: | |
Recovery 330 of Total Fluid 330 of Fluid in Drill Pipe 1710 of Gas in Pipe 30 of Slight oil gas with 8%Gas 2%Oil 30%Water 120 of Oil & Gas cut 20%Gas 5%Oil 50%Water 180 of Slightly mud cut 90%Water 10%Mud 92000 of Salinity (PPM) | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 3 | Data Source: TRILOBITE |
Interval: 5592 to 5620
Formation tested: Morrow | Date, Time: 16-NOV-96; 12:52:16 |
Initial Hydro Pressure: 2759 PSI
First Initial Flow Pressure: 30 PSI First Final Flow Pressure: 92 PSI Initial Shut-in Pressure: 1359 PSI Second Initial Flow Pressure: 91 PSI Second Final Flow Pressure: 140 PSI Final Shut-in Pressure: 1360 PSI Final Hydro Pressure: 2605 PSI |
Tool Data Hole Size: 7.88 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: ft. Drill Pipe Length: 5754 ft. |
Initial Flow - Strong blow - bottom of bucket in 7 min. Initial Shut-in - Bled off 2"" - no blow back Final Flow - Strong blow - bottom of bucket in 4 min. Final Shut-in - Bled off 2"" - no blow back |
|
Bottom Hole Temperature: 126 DEG F
Percent Porosity: Samples: No Gas Recovery: Comments: | |
Recovery 270 of Total Fluid 270 of Fluid in Drill Pipe 4230 of Gas in drilling pipe 30 of watery mud film oil 15%water 85%mud 120 of Slight gas with 15%Gas 25%Water 60%Mud 120 of Slight gas with watery mud 5%Gas 70%Water 63000 of Salinity (PPM) | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |