API: 15-145-21438
Operator: American Energies Corp. Field: Garfield Lease: Meyer 'A' Well 1 |
Location: T22S R17W, Sec. 29, SE SW NW
2310 South, 990 East, from NW corner Longitude: -99.2195389 Latitude: 38.1097675 County: Pawnee Status: D&A |
Spud Date: 11-SEP-96
Completion Date: 20-SEP-96 Plugging Date: 20-SEP-96 Total Depth: 4280 Form. at depth: CHEROKEE GROUP Elevation: 2070 KB |
Test Number: 1 | Data Source: TRILOBITE |
Interval: 2115 to 2130
Formation tested: Herrington | Date, Time: 13-SEP-96; 17:35:32 |
Initial Hydro Pressure: 1075 PSI
First Initial Flow Pressure: 19 PSI First Final Flow Pressure: 29 PSI Initial Shut-in Pressure: 369 PSI Second Initial Flow Pressure: 29 PSI Second Final Flow Pressure: 39 PSI Final Shut-in Pressure: 303 PSI Final Hydro Pressure: 1056 PSI |
Tool Data Hole Size: 7.88 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: 248 ft. Drill Pipe Length: 1845 ft. |
Initial Flow - Weak, building to strong, bottom of bucket in 25 minutes Final Flow - Weak, building to strong, bottom of bucket in 25 minutes |
|
Bottom Hole Temperature: 86 DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 30 of Total Fluid 30 of Fluid in Drill Collars 30 of Muddy water | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 2 | Data Source: TRILOBITE |
Interval: 4093 to 4151
Formation tested: Cong | Date, Time: 17-SEP-96; 16:20:50 |
Initial Hydro Pressure: PSI
First Initial Flow Pressure: PSI First Final Flow Pressure: PSI Initial Shut-in Pressure: PSI Second Initial Flow Pressure: PSI Second Final Flow Pressure: PSI Final Shut-in Pressure: PSI Final Hydro Pressure: PSI |
Tool Data Hole Size: 7.88 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: 248 ft. Drill Pipe Length: 3822 ft. |
Bottom Hole Temperature: DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 338 of Total Fluid 248 of Fluid in Drill Collars 90 of Fluid in Drill Pipe 338 of Drilling mud | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 3 | Data Source: TRILOBITE |
Interval: 4075 to 4151
Formation tested: Cong | Date, Time: 17-SEP-96; 20:05:56 |
Initial Hydro Pressure: PSI
First Initial Flow Pressure: PSI First Final Flow Pressure: PSI Initial Shut-in Pressure: PSI Second Initial Flow Pressure: PSI Second Final Flow Pressure: PSI Final Shut-in Pressure: PSI Final Hydro Pressure: PSI |
Tool Data Hole Size: 7.88 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: 248 ft. Drill Pipe Length: 3824 ft. |
Initial Flow - Weak, building to strong, bottom of bucket in 10 min Final Flow - Strong, bottom of bucket in 1 min |
|
Bottom Hole Temperature: DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 20 of Total Fluid 20 of Fluid in Drill Collars 800 of Gas in pipe 20 of Gassy mud | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |