API: 15-051-25010
Operator: KENMARK CORPORATION Field: Toni-Mike Northeast Lease: FISHER Well 3 |
Location: T11S R18W, Sec. 28, NW SE SW
990 North, 1650 East, from SW corner Longitude: -99.3275807 Latitude: 39.0620617 County: Ellis Status: D&A |
Spud Date: 05-OCT-99
Completion Date: 12-OCT-99 Plugging Date: 12-OCT-99 Total Depth: 3595 Form. at depth: ARBUCKLE Elevation: 2028 KB |
Test Number: 2 | Data Source: TRILOBITE |
Interval: 3352 to 3420
Formation tested: lansing | Date, Time: 10-OCT-99; 05:58:57 |
Initial Hydro Pressure: 1616 PSI
First Initial Flow Pressure: 14 PSI First Final Flow Pressure: 18 PSI Initial Shut-in Pressure: 147 PSI Second Initial Flow Pressure: 18 PSI Second Final Flow Pressure: 18 PSI Final Shut-in Pressure: 96 PSI Final Hydro Pressure: 1606 PSI |
Tool Data Hole Size: 7.78 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: 30 ft. Drill Pipe Length: 3315 ft. |
Initial Flow: Weak blow throughout 1/4"" blow Final Flow: No blow |
|
Bottom Hole Temperature: 103 DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 5 of Total Fluid 5 of Fluid in Drill Collars 5 of mud | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 3 | Data Source: TRILOBITE |
Interval: 3531 to 3568
Formation tested: arbuckle | Date, Time: 11-OCT-99; 03:24:56 |
Initial Hydro Pressure: 1729 PSI
First Initial Flow Pressure: 15 PSI First Final Flow Pressure: 17 PSI Initial Shut-in Pressure: 28 PSI Second Initial Flow Pressure: 17 PSI Second Final Flow Pressure: 18 PSI Final Shut-in Pressure: 24 PSI Final Hydro Pressure: 1728 PSI |
Tool Data Hole Size: 7.78 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: 30 ft. Drill Pipe Length: 3534 ft. |
Initial Flow: Weak blow died in 15 mins. Final Flow: No blow |
|
Bottom Hole Temperature: 107 DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 5 of Total Fluid 5 of Fluid in Drill Collars 5 of mud | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 4 | Data Source: TRILOBITE |
Interval: 3564 to 3581
Formation tested: arbuckle | Date, Time: 11-OCT-99; 12:51:59 |
Initial Hydro Pressure: 1769 PSI
First Initial Flow Pressure: 16 PSI First Final Flow Pressure: 17 PSI Initial Shut-in Pressure: 55 PSI Second Initial Flow Pressure: 18 PSI Second Final Flow Pressure: 18 PSI Final Shut-in Pressure: 46 PSI Final Hydro Pressure: 1749 PSI |
Tool Data Hole Size: 7.78 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: 30 ft. Drill Pipe Length: 3564 ft. |
Initial Flow: Weak blow throughout 1/4"" to surface blow Final Flow: Weak blow throughout out surface blow |
|
Bottom Hole Temperature: 103 DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 15 of Total Fluid 15 of Fluid in Drill Collars 15 of Mud with show of oil on top of tool | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 5 | Data Source: TRILOBITE |
Interval: 3568 to 3595
Formation tested: Arbuckle | Date, Time: 11-OCT-99; 23:02:35 |
Initial Hydro Pressure: 1737 PSI
First Initial Flow Pressure: 14 PSI First Final Flow Pressure: 35 PSI Initial Shut-in Pressure: 937 PSI Second Initial Flow Pressure: 37 PSI Second Final Flow Pressure: 45 PSI Final Shut-in Pressure: 869 PSI Final Hydro Pressure: 1723 PSI |
Tool Data Hole Size: 7.78 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: 30 ft. Drill Pipe Length: 3534 ft. |
Initial Flow: Weak blow throughout 1/2"" to 1/4"" blow Final Flow: Weak blow throughout 1"" to 1 1/4"" blow |
|
Bottom Hole Temperature: 107 DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 70 of Total Fluid 30 of Fluid in Drill Collars 40 of Fluid in Drill Pipe 10 of Slight oil cut mud 2%oil 98%mud 60 of Slight oil cut mud 1%oil 99%mud | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |
Test Number: 1 | Data Source: TRILOBITE |
Interval: 3309 to 3350
Formation tested: lansing c&d | Date, Time: 09-OCT-99; 15:05:21 |
Initial Hydro Pressure: 1611 PSI
First Initial Flow Pressure: 17 PSI First Final Flow Pressure: 88 PSI Initial Shut-in Pressure: 108 PSI Second Initial Flow Pressure: 107 PSI Second Final Flow Pressure: 110 PSI Final Shut-in Pressure: 115 PSI Final Hydro Pressure: 1592 PSI |
Tool Data Hole Size: 7.78 in. Drill Collar ID: 2.25 in. Drill Pipe ID: 3.8 in. Drill Collar Length: 30 ft. Drill Pipe Length: 3282 ft. |
Initial Flow: Weak blot throughout 1/2"" to 1 1/2"" blow Final Flow: Weak blow died in 7 mins. |
|
Bottom Hole Temperature: 104 DEG F
Percent Porosity: Samples: Gas Recovery: Comments: | |
Recovery 35 of Total Fluid 30 of Fluid in Drill Collars 5 of Fluid in Drill Pipe 35 of mud | |
View Pressures | No Recovery Gas data. |
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display. | |