Drill Stem Tests Database
Specific Well--15-051-25010
API: 15-051-25010
Operator: KENMARK CORPORATION
Field: Toni-Mike Northeast
Lease: FISHER
Well 3
Location: T11S R18W, Sec. 28, NW SE SW
990 North, 1650 East, from SW corner
Longitude: -99.3275807
Latitude: 39.0620617
County: Ellis
Status: D&A
Spud Date: 05-OCT-99
Completion Date: 12-OCT-99
Plugging Date: 12-OCT-99
Total Depth: 3595
Form. at depth: ARBUCKLE
Elevation: 2028 KB
Test Number: 2 Data Source: TRILOBITE
Interval: 3352 to 3420
Formation tested: lansing
Date, Time: 10-OCT-99; 05:58:57
Initial Hydro Pressure: 1616 PSI
First Initial Flow Pressure: 14 PSI
First Final Flow Pressure: 18 PSI
Initial Shut-in Pressure: 147 PSI
Second Initial Flow Pressure: 18 PSI
Second Final Flow Pressure: 18 PSI
Final Shut-in Pressure: 96 PSI
Final Hydro Pressure: 1606 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 30 ft.
Drill Pipe Length: 3315 ft.
Initial Flow: Weak blow throughout 1/4"" blow
Final Flow: No blow
Bottom Hole Temperature: 103 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
5 of Total Fluid
5 of Fluid in Drill Collars
5 of mud
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 3 Data Source: TRILOBITE
Interval: 3531 to 3568
Formation tested: arbuckle
Date, Time: 11-OCT-99; 03:24:56
Initial Hydro Pressure: 1729 PSI
First Initial Flow Pressure: 15 PSI
First Final Flow Pressure: 17 PSI
Initial Shut-in Pressure: 28 PSI
Second Initial Flow Pressure: 17 PSI
Second Final Flow Pressure: 18 PSI
Final Shut-in Pressure: 24 PSI
Final Hydro Pressure: 1728 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 30 ft.
Drill Pipe Length: 3534 ft.
Initial Flow: Weak blow died in 15 mins.
Final Flow: No blow
Bottom Hole Temperature: 107 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
5 of Total Fluid
5 of Fluid in Drill Collars
5 of mud
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 4 Data Source: TRILOBITE
Interval: 3564 to 3581
Formation tested: arbuckle
Date, Time: 11-OCT-99; 12:51:59
Initial Hydro Pressure: 1769 PSI
First Initial Flow Pressure: 16 PSI
First Final Flow Pressure: 17 PSI
Initial Shut-in Pressure: 55 PSI
Second Initial Flow Pressure: 18 PSI
Second Final Flow Pressure: 18 PSI
Final Shut-in Pressure: 46 PSI
Final Hydro Pressure: 1749 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 30 ft.
Drill Pipe Length: 3564 ft.
Initial Flow: Weak blow throughout 1/4"" to surface blow
Final Flow: Weak blow throughout out surface blow
Bottom Hole Temperature: 103 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
15 of Total Fluid
15 of Fluid in Drill Collars
15 of Mud with show of oil on top of tool
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 5 Data Source: TRILOBITE
Interval: 3568 to 3595
Formation tested: Arbuckle
Date, Time: 11-OCT-99; 23:02:35
Initial Hydro Pressure: 1737 PSI
First Initial Flow Pressure: 14 PSI
First Final Flow Pressure: 35 PSI
Initial Shut-in Pressure: 937 PSI
Second Initial Flow Pressure: 37 PSI
Second Final Flow Pressure: 45 PSI
Final Shut-in Pressure: 869 PSI
Final Hydro Pressure: 1723 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 30 ft.
Drill Pipe Length: 3534 ft.
Initial Flow: Weak blow throughout 1/2"" to 1/4"" blow
Final Flow: Weak blow throughout 1"" to 1 1/4"" blow
Bottom Hole Temperature: 107 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
70 of Total Fluid
30 of Fluid in Drill Collars
40 of Fluid in Drill Pipe
10 of Slight oil cut mud 2%oil 98%mud
60 of Slight oil cut mud 1%oil 99%mud
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 1 Data Source: TRILOBITE
Interval: 3309 to 3350
Formation tested: lansing c&d
Date, Time: 09-OCT-99; 15:05:21
Initial Hydro Pressure: 1611 PSI
First Initial Flow Pressure: 17 PSI
First Final Flow Pressure: 88 PSI
Initial Shut-in Pressure: 108 PSI
Second Initial Flow Pressure: 107 PSI
Second Final Flow Pressure: 110 PSI
Final Shut-in Pressure: 115 PSI
Final Hydro Pressure: 1592 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 30 ft.
Drill Pipe Length: 3282 ft.
Initial Flow: Weak blot throughout 1/2"" to 1 1/2"" blow
Final Flow: Weak blow died in 7 mins.
Bottom Hole Temperature: 104 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
35 of Total Fluid
30 of Fluid in Drill Collars
5 of Fluid in Drill Pipe
35 of mud
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.