Drill Stem Tests Database
Specific Well--15-189-22308
API: 15-189-22308
Operator: Oxy USA, Inc.
Field: Youngren
Lease: MLP CAVNER 'A'
Well 3
Location: T31S R38W, Sec. 31, SW NE NE SW
2275 North, 2170 East, from SW corner
Longitude: -101.4940807
Latitude: 37.3071964
County: Stevens
Status: OIL-P&A
Spud Date: 18-JUN-99
Completion Date: 21-JUL-99
Plugging Date: 09-JUL-10
Total Depth: 6145
Form. at depth: ST LOUIS
Elevation: 3103 KB
SAMPLES MARKED #3 MLP CAVNERS 'A'. This well has been referred to as the 'MLP CAVNER E1', too.

Download DST Test Data

Test Number: 1 Data Source: TRILOBITE
Interval: 5696 to 5708
Formation tested: Lower Morrow
Date, Time: 26-JUN-99; 06:41:21
Initial Hydro Pressure: 2871 PSI
First Initial Flow Pressure: 2287 PSI
First Final Flow Pressure: 2273 PSI
Initial Shut-in Pressure: 2281 PSI
Second Initial Flow Pressure: 2534 PSI
Second Final Flow Pressure: 2538 PSI
Final Shut-in Pressure: 2489 PSI
Final Hydro Pressure: 2664 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 593 ft.
Drill Pipe Length: 5077 ft.
Initial Flow: Strong blow bottom of bucket in 5 mins. Initial Shut-in: Bled off 2"" no blow back
Final Flow: No blow
Bottom Hole Temperature: 127 DEG F
Percent Porosity:
Samples: NO
Gas Recovery:
Comments:
Recovery
90 of Total Fluid
90 of Fluid in Drill Collars
90 of Drilling mud
View Pressures No Recovery Gas data.
 
Test Number: 2 Data Source: TRILOBITE
Interval: 5696 to 5708
Formation tested: Lower Morrow
Date, Time: 27-JUN-99; 01:35:37
Initial Hydro Pressure: 2690 PSI
First Initial Flow Pressure: 291 PSI
First Final Flow Pressure: 2249 PSI
Initial Shut-in Pressure: 2421 PSI
Second Initial Flow Pressure: 461 PSI
Second Final Flow Pressure: 444 PSI
Final Shut-in Pressure: 1662 PSI
Final Hydro Pressure: 2658 PSI
Tool Data
Hole Size: 7.78 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 593 ft.
Drill Pipe Length: 5077 ft.
Initial Flow: Strong blow bottom of bucket in 1 min Initial Shut-in: Bled off blow no blow back
Final Flow: No blow bottom of bucket in 7 mins. lost packer seat bled off got packer seat again 2ft. lower gas to surface in 42 mins. to weak to gauge gas will burn
Bottom Hole Temperature: 128 DEG F
Percent Porosity:
Samples: Yes 1
Gas Recovery:
Comments:
Recovery
925 of Total Fluid
595 of Fluid in Drill Collars
330 of Fluid in Drill Pipe
925 of Gassy Mud 20% gas 80% mud
View Pressures No Recovery Gas data.