Drill Stem Tests Database
Specific Well--15-101-21772
API: 15-101-21772
Operator: Denis Roberts Oil
Field: Paris
Lease: Hansen
Well 2
Location: T19S R29W, Sec. 23, E2 W2 NE
3931 North, 1708 West, from SE corner
Longitude: -100.4896844
Latitude: 38.3909851
County: Lane
Status: OIL
Spud Date: 06-NOV-99
Completion Date: 18-NOV-99
Plugging Date:
Total Depth: 4555
Form. at depth: MARMATON
Elevation: 2830 KB
Test Number: 1 Data Source: TRILOBITE
Interval: 4170 to 4255
Formation tested: Muncie Crk ""H"" ""I""
Date, Time: 15-NOV-99; 14:46:43
Initial Hydro Pressure: 2098 PSI
First Initial Flow Pressure: 139 PSI
First Final Flow Pressure: 619 PSI
Initial Shut-in Pressure: 1043 PSI
Second Initial Flow Pressure: 636 PSI
Second Final Flow Pressure: 947 PSI
Final Shut-in Pressure: 1019 PSI
Final Hydro Pressure: 2042 PSI
Tool Data
Hole Size: 8.875 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 30 ft.
Drill Pipe Length: 4134 ft.
Initial Flow: Fair to strong blow off bottom in 2 mins. Initial Shut-in: Surface blow built to 1/2""
Final Flow: Fair to strong blow off bottom in 2 mins.
Final Shut-in: No return blow
Bottom Hole Temperature: 118 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
2055 of Total Fluid
30 of Fluid in Drill Collars
2025 of Fluid in Drill Pipe
130 of Slight gas cut oil 25%gas 75%oil
310 of Slight gassy oily mud cut water
745 of Slight gassy oily mud cut water
370 of Slight oily mud cut water
500 of Salt water
23000 of Salinity (PPM)
36 of Gravity (API)
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 2 Data Source: TRILOBITE
Interval: 4295 to 4351
Formation tested: L/KC ""K"" thru ""L""
Date, Time: 16-NOV-99; 13:37:51
Initial Hydro Pressure: 2111 PSI
First Initial Flow Pressure: 116 PSI
First Final Flow Pressure: 432 PSI
Initial Shut-in Pressure: 782 PSI
Second Initial Flow Pressure: 441 PSI
Second Final Flow Pressure: 652 PSI
Final Shut-in Pressure: 789 PSI
Final Hydro Pressure: 2096 PSI
Tool Data
Hole Size: 8.875 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 30 ft.
Drill Pipe Length: 4318 ft.
Initial Flow: Fair to strong blow off bottom in 3 mins. Initial Shut-in: No return blow
Final Flow: Fair to strong blow off bttm in 5 mins.
Final Shut-in: No return blow
Bottom Hole Temperature: 128 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
1410 of Total Fluid
30 of Fluid in Drill Collars
1380 of Fluid in Drill Pipe
1410 of Salt water with trace of oil
26000 of Salinity (PPM)
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 3 Data Source: TRILOBITE
Interval: 4425 to 4478
Formation tested: Altamont ""B""
Date, Time: 17-NOV-99; 20:43:42
Initial Hydro Pressure: 2260 PSI
First Initial Flow Pressure: 22 PSI
First Final Flow Pressure: 23 PSI
Initial Shut-in Pressure: 99 PSI
Second Initial Flow Pressure: 25 PSI
Second Final Flow Pressure: 28 PSI
Final Shut-in Pressure: 78 PSI
Final Hydro Pressure: 2243 PSI
Tool Data
Hole Size: 8.875 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 30 ft.
Drill Pipe Length: 4410 ft.
Initial Flow: Weak surface blow died in 5 mins.
Final Flow: No return blow - flushed tool/good surge - no blow back
Bottom Hole Temperature: 120 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
3 of Total Fluid
3 of Fluid in Drill Collars
3 of Drilling mud with show of oil
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 4 Data Source: TRILOBITE
Interval: 4236 to 4255
Formation tested: L/KC ""I""
Date, Time: 18-NOV-99; 03:15:19
Initial Hydro Pressure: 2103 PSI
First Initial Flow Pressure: 33 PSI
First Final Flow Pressure: 87 PSI
Initial Shut-in Pressure: 814 PSI
Second Initial Flow Pressure: 96 PSI
Second Final Flow Pressure: 170 PSI
Final Shut-in Pressure: 786 PSI
Final Hydro Pressure: 2093 PSI
Tool Data
Hole Size: 8.875 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 30 ft.
Drill Pipe Length: 4190 ft.
Initial Flow: Weak to fair blow off bttm in 17 mins. Initial Shut-in: Surface return died at 25 mins.
Final Flow: Weak to fair blow off bttm in 20 mins.
Final Shut-in: No return blow
Bottom Hole Temperature: 119 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
415 of Total Fluid
30 of Fluid in Drill Collars
385 of Fluid in Drill Pipe
295 of Clean gassy oil 20%gas 80%oil
120 of Gassy oil cut mud 40%gas 10%oil 50%water
36 of Gravity (API)
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.