Drill Stem Tests Database
Specific Well--15-033-21072
API: 15-033-21072
Operator: AMERICAN WARRIOR INC.
Field: Hack
Lease: Lytle
Well 1-17
Location: T33S R18W, Sec. 17, SE NW
2120 South, 2100 East, from NW corner
Longitude: -99.3017
Latitude: 37.17303
County: Comanche
Status: GAS-P&A
Spud Date: 21-MAR-00
Completion Date: 24-APR-00
Plugging Date: 30-DEC-09
Total Depth: 6272
Form. at depth: ARBUCKLE
Elevation: 2110 KB
Discovery well for Hack field.
Test Number: 1 Data Source: TRILOBITE
Interval: 5095 to 5165
Formation tested: Pawnee/Ft.Scott
Date, Time: 29-MAR-00; 11:29:24
Initial Hydro Pressure: 2508 PSI
First Initial Flow Pressure: 38 PSI
First Final Flow Pressure: 53 PSI
Initial Shut-in Pressure: 1595 PSI
Second Initial Flow Pressure: 43 PSI
Second Final Flow Pressure: 57 PSI
Final Shut-in Pressure: 1876 PSI
Final Hydro Pressure: 2571 PSI
Tool Data
Hole Size: 7.88 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 294.4 ft.
Drill Pipe Length: ft.
Initial Flow: Strong blow bottom of bucket in 30 seconds. Initial Shut-In: Bled down for 10 minutes. No blow back.
Final Flow: Strong blow bottom of bucket in 15 seconds. Gas to surface in 5 minutes. Gauged gas.
Final Shut-In: Bled down for 10 minutes. No blow back.
Bottom Hole Temperature: 125 DEG F
Percent Porosity:
Samples: Caraway Analytical 728 N.Roosevelt
Gas Recovery:
Comments:
Recovery
90 of Total Fluid
90 of Fluid in Drill Collars
5000 of Gas in pipe.
90 of Very slight gas cut mud
View Pressures View Recovery Gas
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 2 Data Source: TRILOBITE
Interval: 5872 to 5899
Formation tested: viola
Date, Time: 01-APR-00; 04:49:55
Initial Hydro Pressure: 2912 PSI
First Initial Flow Pressure: 2088 PSI
First Final Flow Pressure: 2087 PSI
Initial Shut-in Pressure: 2174 PSI
Second Initial Flow Pressure: 2085 PSI
Second Final Flow Pressure: 2073 PSI
Final Shut-in Pressure: 2173 PSI
Final Hydro Pressure: 2907 PSI
Tool Data
Hole Size: 7.88 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 294.4 ft.
Drill Pipe Length: ft.
Initial Flow: Strong blow - bottom of bucket in 10 seconds - Gas to surface in 1 min gauged gas Initial Shutin: Bled down for 45 minutes built back to 1/2"" in bucket
Final Flow: Strong blow - bottom of bucket in 10 seconds - gauged gas
Final Shutin: Bled down for 60 minutes built back to 3/4"" in bucket
Bottom Hole Temperature: 144 DEG F
Percent Porosity:
Samples: Caraway Analytical 728 N.Roosevelt
Gas Recovery:
Comments:
View Pressures View Recovery Gas
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.
 
Test Number: 3 Data Source: TRILOBITE
Interval: 6177 to 6233
Formation tested: Arbukle
Date, Time: 03-APR-00; 13:44:50
  Tool Data
Hole Size: 7.88 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.8 in.
Drill Collar Length: 294.4 ft.
Drill Pipe Length: ft.
Initial Flow: Weak blow built to 1 1/2"" in bucket Initial Shutin: Bled down for 2 minutes - no blow back
Final Flow: no blow
Final Shutin: no blow back
Bottom Hole Temperature: 138 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
120 of Total Fluid
120 of Fluid in Drill Collars
120 of drilling mud
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.