Drill Stem Tests Database
Specific Well--15-101-21662-0001
API: 15-101-21662-0001
Operator: RHEEM RESOURCES
Field: Hineman
Lease: WARREN TOBUREN
Well 1
Location: T19S R28W, Sec. 20, NE SE NE
3630 North, 330 West, from SE corner
Longitude: -100.4299295
Latitude: 38.3898407
County: Lane
Status: D&A
Spud Date: 12-APR-96
Completion Date: 19-APR-96
Plugging Date: 19-APR-96
Total Depth: 4420
Form. at depth: MISSISSIPPIAN
Elevation: 2793 KB
Test Number: 1 Data Source: TRILOBITE
Interval: 4390 to 4420
Formation tested: Pleasanton
Date, Time: 18-APR-96; 00:20:16
Initial Hydro Pressure: 2167 PSI
First Initial Flow Pressure: 23 PSI
First Final Flow Pressure: 183 PSI
Initial Shut-in Pressure: 665 PSI
Second Initial Flow Pressure: 185 PSI
Second Final Flow Pressure: 234 PSI
Final Shut-in Pressure: 646 PSI
Final Hydro Pressure: 2129 PSI
Tool Data
Hole Size: 7.875 in.
Drill Collar ID: 2.25 in.
Drill Pipe ID: 3.5 in.
Drill Collar Length: 310 ft.
Drill Pipe Length: 4092 ft.
Initial Flow - Bottom of bucket in 14.5 min, fair blow
Initial Shutin - Bled off blow, return blow in 5 min, very weak surface blow
Final Flow - Weak surface blow, built to bottom of bucket in 1 hour 6 min, fair blow
Final Shutin - Bled off blow, return blow in 5 min, built to .125"" weak blow
Bottom Hole Temperature: 127 DEG F
Percent Porosity:
Samples:
Gas Recovery:
Comments:
Recovery
506 of Total Fluid
310 of Fluid in Drill Collars
196 of Fluid in Drill Pipe
170 of Gas in pipe
41 of Clean gassy oil - 20% gas, 80% oil
155 of Slightly gassy oil cut mud -
124 of Muddy water - 60% water, 40% mud
186 of Slightly muddy water - 90% water, 10% mud
7950 of Salinity (PPM)
40 of Gravity (API)
View Pressures No Recovery Gas data.
Download original data
ZIP file contains the orignal DST data supplied to the KGS by Trilobite Testing LLC . Four files are in each archive. The .flg file is an ascii file that has time and pressure at change points (open, shutin, etc.). The .csv is the original data extracted into a comma delimited file. The last two files (the .inf file and a file with a variable extension) are binary files that require Alpine DST software for display.