Specific Well--15-065-23209-0001
Engineering Data | ||
View General Well Data | Viewing Engineering Data |
API: 15-065-23209-0001
KID: 1046522415 Lease: MORPHEW Well: 4-33 Original operator: Vincent Oil Corporation Current operator: Vincent Oil Corporation Field: Harmony Location: T7S R22W, Sec. 33 SW SW SE 400 North, 2050 West, from SE corner NAD27 Longitude: -99.7775842 NAD27 Latitude: 39.3949019 NAD83 Longitude: -99.77798 NAD83 Latitude: 39.39491 Lat-long from GPS |
County: Graham
Permit Date: Spud Date: Oct-09-2017 Completion Date: Oct-12-2017 Plugging Date: Well Type: EOR Status: Authorized Injection Well Total Depth: 3825 Elevation: 2192 KB Producing Formation: IP Oil (bbl): IP Water (bbl): IP GAS (MCF): KDOR code for Oil: 137179 KCC Permit No.: |
View well on interactive map
View well in the Walter’s Digital Library (WDL login required) |
Drill Stem Tests Taken: No Samples Set to Survey: No Cores Taken: No Electric Logs Run: No Method of Completion: Date of First or Resumed Production/Injection: |
Producing Method: Estimated production per 24 hours Oil: Water: Gas: Disposition of Gas: Tubing record Size: 2.3750 Set at: 3545 Packer at: 3545 Production intervals: |
Casing recordnew or used? New |
|||||||
Purpose of String | Size Hole Drilled |
Size Casing Set (in O.D.) |
Weight Lbs/Ft |
Setting Depth |
Type of Cement |
# Sacks Used |
Type and Percent Additives |
---|---|---|---|---|---|---|---|
Surface | 12.25 | 8.625 | 23 | 219 | Common | 160 | 2% Gel & 3% CC) |
Production | 7.875 | 4.5 | 10.5 | 3816 | ASC | 160 | 2% Gel |
Additional Cementing/Squeeze Recordpurpose? |
|||||||
Depth Top Bottom |
Type of Cement | # Sacks Used | Type and Percent Additives |
---|
Perforation Record |
|||||||
Shots Per Foot | Perforation Top |
Perforation Bottom |
Bridge Plug Type |
Bridge Plug Set At |
Material Record | ||
---|---|---|---|---|---|---|---|
4 | 3582 | 3585 | Existing perforations | ||||
4 | 3600 | 3606 | Existing perforations | ||||
Pulled existing rods, tubing & downhole pump, ran tubing and packer and set above existing perforations. | |||||||
Took short rate test, set packer, loaded tubing / casing annulus & tested to 350# with no loss. | |||||||
Released packer, TOH with tubing & packer. 2.3750" lined tubing was run on a lined AD-1 packer and set at a depth of 3545'. | |||||||
The tubing / casing annulus was loaded with freshwater & packer fluid. | |||||||
Following a State witnessed Mechanical Integrity pressure test to 325# the well was shut in awaiting issuance of a final EOR injection permit |
Please note: The link below takes you away from the web site of the Kansas Geological Survey to the website of the Kansas Geological Society, a library in Wichita. The Survey can not help with information presented by the Walters Digital Library.
From Kansas Geological Society's Walters Digital Library