Specific Well--15-057-21058
Engineering Data | ||
View General Well Data | Viewing Engineering Data |
API: 15-057-21058
KID: 1052079205 Lease: SWONGER Well: 4-4 Original operator: Vincent Oil Corp. Current operator: Vincent Oil Corporation Field: Mulberry Creek Location: T29S R23W, Sec. 4 E2 NW NE NW 330 South, 1930 East, from NW corner NAD27 Longitude: -99.84377 NAD27 Latitude: 37.5567991 NAD83 Longitude: -99.8441778 NAD83 Latitude: 37.5568203 Lat-long calculated from footages |
County: Ford
Permit Date: Oct-06-2021 Spud Date: Oct-19-2021 Completion Date: Jan-05-2022 Plugging Date: Well Type: OIL Status: Producing Total Depth: 5224 Elevation: 2492 KB Producing Formation: Mississippian IP Oil (bbl): IP Water (bbl): IP GAS (MCF): KCC Permit No.: |
View well on interactive map
View well in the Walter’s Digital Library (WDL login required) |
Drill Stem Tests Taken: Yes Samples Set to Survey: Yes Cores Taken: No Electric Logs Run: Yes Attached Method of Completion: Perforated Date of First or Resumed Production/Injection: Jan. 05, 2022 |
Producing Method: Pumping Estimated production per 24 hours Oil: 40 Water: 7 Gas: Disposition of Gas: Tubing record Size: 2.3750 Set at: 5195 Packer at: None Production intervals: 5188 ; 5210 ; 5194 ; 5214 |
Casing recordnew or used? New |
|||||||
Purpose of String | Size Hole Drilled |
Size Casing Set (in O.D.) |
Weight Lbs/Ft |
Setting Depth |
Type of Cement |
# Sacks Used |
Type and Percent Additives |
---|---|---|---|---|---|---|---|
Surface | 12.25 | 8.625 | 23 | 647 | MDC & Common | 300 | 0-2% Gel, 3% CC & 1/2# Flo-seal/sx |
Production | 7.875 | 4.5 | 11.6 | 5223 | Pro-C | 175 | 2% Gel & 10% Salt |
Additional Cementing/Squeeze Recordpurpose? |
|||||||
Depth Top Bottom |
Type of Cement | # Sacks Used | Type and Percent Additives |
---|
Perforation Record |
|||||||
Shots Per Foot | Perforation Top |
Perforation Bottom |
Bridge Plug Type |
Bridge Plug Set At |
Material Record | ||
---|---|---|---|---|---|---|---|
3 | 5188 | 5194 | Swabbed down, Acidized with 1000 gal MCA, Swab tested | ||||
4 | 5210 | 5214 | Swab tested, Acidized with 750 gallons MCA, Swab tested | ||||
Problem with packer placement, reset tubing and packer and swab tested. | |||||||
Ran tubing, rods and downhole equip, Set surface equip and turned to production 1/5/2022 |
Please note: The link below takes you away from the web site of the Kansas Geological Survey to the website of the Kansas Geological Society, a library in Wichita. The Survey can not help with information presented by the Walters Digital Library.
From Kansas Geological Society's Walters Digital Library