~Version Information
VERS. 2.0: CWLS Log ASCII Standard - VERSION 2.0
WRAP. NO: One line per depth step
~Well Information Block
STRT.FT 170.0000: START DEPTH
STOP.FT 3743.5000: STOP DEPTH
STEP.FT 0.2500: STEP
NULL. -999.2500: NULL VALUE
COMP. John O. Farmer, Inc.: COMPANY
WELL. States B #1: WELL
FLD. Ray: FIELD
LOC. 2085' FNL & 475' FWL--: LOCATION
CNTY. Phillips: COUNTY
SRVC. Gemini Wireline LLC: SERVICE COMPANY
DATE. Mon May 05 04-05-33 2014: LOG DATE
UWI. 15 147 20737: UNIQUE WELL ID
STAT. KS: STATE
SECT. 30: SECTION
TOWN. 5S: TOWNSHIP
RANG. 20W: RANGE
API. : API#
OS. --ML--DIL--: OTHER SERVICES
PDAT.FT Ground Level: PERMANENT DATUM
EEL.FT
2233': ELEVATION
LMF.FT KB 5' AGL: LOG MEASURED FROM
DMF.FT KB: DRILLING MEASURED FROM
EKB.FT 2238': KB
EDF.FT 2237': DF
EGL.FT 2233': GL
DATE1. 5-5-14: DATE1
RUN1. One: RUN NUMBER
TDD1.FT 3740': DEPTH DRILLER
TDL1.FT 3740': DEPTH LOGGER
BLI1.FT 3707': BOTTOM LOGGED INTERVAL
TLI1.FT 3150': TOP LOG INTERVAL
CDD1.IN_FT 217': CASING DRILLER
CDL1.FT 217': CASING LOGGER
BS1.IN 7 7/8": BIT SIZE
DFT1. Chemical Mud: TYPE FLUID IN HOLE
DFDV1.GM/C3_CP 9.4/54: DENSITY/VISCOSITY
DFPL1.C3 10/8: PH/FLUID LOSS
MSS1. Pit: SOURCE OF SAMPLE
RMT1.OHHM_DEGF .9@60degf: RM@MEASURED TEMP
RMFT1.OHMM_DEGF .68@60degf: RMF@MEASURED TEMP
RMCT1.OHMM_DEGF 1.1@60degf: RMC@MEASURED TEMP
RMFS1.
Calculated: SOURCE OF RMF/RMC
RMBT1.OHMM_DEGF .46@116degf: RM@BHT
TCS1. 12:01 a.m.: TIME CIRCULATION STOPPED
TLOB1. 2:35 a.m.: TIME LOGGER ON BOTTOM
BHT1.DEGF 116 degf: MAXIMUM RECORDED TEMPERATURE
LUN1. T127: EQUIPMENT NUMBER
LUL1. Hays, KS.: LOCATION
ENGI1. Gus Pfanenstiel: RECORDED BY
WITN1. Mr. Austin Klaus: WITNESSED BY
~Curve Information Block
DEPT.FT 0 000 00 00: Depth
DCAL.IN : CDL Caliper
DPOR.PU : CDL Density Porosity
GR.GAPI : Gamma Ray
NPOR.PU : Neutron Porosity
RHOC.G/CC : CDL Density Correction
RILD.OHM-M : DIL Deep Resistivity
RILM.OHM-M : DIL Medium Resistivity
RLL3.OHM-M : DIL Shallow Resistivity
SP.MV : DIL Spontaneous Potential
MCAL.IN : Calipe
r from Microlog
MI.OHM-M : Micro Inverse Resistivity
MN.OHM-M : Micro Normal Resistivity
~Parameter Information Block
~Other Information
Thank you for using Gemini Wireline
785-625-1182
|