~Version Information
VERS. 2.00: CWLS log ASCII Standard -VERSION 2.00
WRAP. NO: One line per frame
~Well Information Block
#MNEM.UNIT Data Description
#----.---- ---------------------------------------- -------------------------------
STRT.FT 1800.000 : Starting Depth
STOP.FT 5007.500 : Ending Depth
STEP.FT 0.250 : Level Spacing
NULL. -999.2500 : Absent Value
COMP. MERIT ENERGY COMPANY : Company
WELL. CARRIE 15-1 : Well
FLD . WILDCAT : Field
LOC . 1632 FEL & 2315 FNL : Location
PROV. FINNEY : Province
CTRY. : Country
SRVC. Bak
er Hughes : Service Company
DATE. 05-Mar-2020 : Log Date
UWI . 15-093-21978-00-00 : Unique Well ID
LIC . : License Number
~Curve Information Block
#MNEM .UNIT API Codes Curve Description
#--------.-------- LG--CV-CL--M ---------------------------------------------------
DEPT .FT 99 995 99 1 : Depth
BVOL .F3 70 995 99 1 : Borehole volume
CALX .IN 70 280 13 1 : Caliper from X-axis of XY caliper(s)
CNCF .PU 42 995 99 1 : Field normalized compensated neutron porosity
CVOL .F3 70 995 99 1 : Cement volume
DT24 .US/F 60 520 99 1 : Slowness over 24-inch interval
GR .GAPI 30 310 1 1 : Gamma ray
KTH .GAPI 31 995 99 1 : Stripped potassium-thorium
KTHC .GAPI 31 995 99 1 : Stripped potassium-thorium, borehole corrected
M0C2 .MM
HO 99 995 99 1 : Focused conductivity, 20-inch DOI
M0C6 .MMHO 99 995 99 1 : Focused conductivity, 60-inch DOI
M0CX .MMHO 99 995 99 1 : Focused conductivity, 120-inch DOI
M2R1 .OHMM 8 120 10 1 : Vertical 2-foot resolution matched resistivity, 10-inch DOI
M2R2 .OHMM 8 120 20 1 : Vertical 2-foot resolution matched resistivity, 20-inch DOI
M2R3 .OHMM 8 120 30 1 : Vertical 2-foot resolution matched resistivity, 30-inch DOI
M2R6 .OHMM 8 120 60 1 : Vertical 2-foot resolution matched resistivity, 60-inch DOI
M2R9 .OHMM 8 120 90 1 : Vertical 2-foot resolution matched resistivity, 90-inch DOI
M2RX .OHMM 8 120 99 1 : Vertical 2-foot resolution matched resistivity, 120-inch DOI
PE .B/E 45 358 1 1 : Photo electric cross-section
PORZC .PU 99 995 99 1 : Corrected porosity
RLML .m.ohm 15 250 1 1 : 1-inch lateral resistivity
RNML .m.ohm 15 252 1 1 : 2-inc
h normal resistivity
SP .MV 1 10 1 1 : Spontaneous Potential
TEN .LBF 99 635 99 1 : Differential tension
WRM .OHMM 99 823 99 1 : Mud resistivity
WTBH .DEGF 99 995 99 1 : Temperature of borehole
ZCOR .G/C3 45 356 99 1 : Density correction
ZDEN .G/C3 45 350 1 1 : Formation bulk density
~Parameter Information Block
#MNEM.UNIT Value Description
#----.---- ---------------------------------------- -------------------------------
HIDE. HIGH DEFINITION INDUCTION LOG^S : Header Identifier
HID1. COMPENSATED NEUTRON LOG : Header Identifier
HID2. COMPENSATED Z-DENSILOG^S : Header Identifier
HID3. DIGITAL ACOUSTILOG : Header Identifier
HID4. MINILOG^R : Header Identifier
HID5. GAMMA RAY LOG : Header Identifier
HID6.
CALIPER LOG : N/A
STAT. KANSAS : State Or Province
APIN. 15-093-21978-00-00 : API Serial Number
SECT. 15 : Section
TOWN. 23S : Township
RANG. 35W : Range
OS1 . DAL/GR : Other Services Line 1
OS2 . HDIL/GR : Other Services Line 2
OS3 . ZDL/CN/GR : Other Services Line 3
OS4 . ZDL/CN/HDIL/GR : Other Services Line 4
OS5 . ML/GR : Other Services Line 5
PDAT. G.L. : Permanent Datum
EPD .FT 3020.6 : Elevation Of Perm. Datum
LMF . K.B. : Log Measure
d From
APD .FT 12 : Above Permanent Datum
DMF . K.B. : Drilling Measured From
EKB .FT 3033 : Elevation Of Kelly Bushing
EDF .FT 3032 : Elevation Of Derrick Floor
EGL .FT 3021 : Elevation Of Ground Level
RUN . 1 : Run Number
TRIP. 1 : Trip Number
SON . US165109 : Service Order Number
TDD .FT 5000 : Total Depth - Driller
TDL .FT 5001 : Total Depth - Logger
BLI .FT 5001 : Bottom Log Interval
TLI .FT 1828 : Top Log Interval
CSIZ.IN 8.625 : Casing Size
CBD
R.FT 1832 : Casing Bottom - Driller
CBLO.FT 1828 : Casing Bottom - Logger
BS .IN 7.875 : Bit Size
DFT . OBM : Drilling Fluid Type
DFD .LB/G 9.35 : Drilling Fluid Density
DFV .CP 52 : Drilling Fluid Viscosity
DFPH. 11 : Drilling Fluid Ph
DFL .C3 6.4 : Drilling Fluid Loss
MSS . PIT : Mud Sample Source
RMS .OHMM 3.038 : Resistivity Of Mud Sample
MST .DEGF 75 : Mud Sample Temperature
RMFS.OHMM 2.278 : Resistivity Of Mud Filtrate Sample
MFST.DEGF 75 : Mud Filtrate
Sample Temperature
RMCS.OHMM 3.797 : Resistivity Of Mud Cake Sample
MCST.DEGF 75 : Mud Cake Sample Temperature
MFSS. CALCULATED : Mud Filtrate Sample Source
MCSS. CALCULATED : Mud Cake Sample Source
RMB .OHMM 2.024 : Mud Resistivity At Bht
BHT .DEGF 116 : Bottom Hole Temperature
TSC . 5 HRS : Time Since Circulation
MRT .DEGF 116 : Maximum Recorded Temperature
LUN . HL-6670 : Logging Unit Number
LUL . OKC,OK : Logging Unit Location
ENGI. S.Yassa : Engineer's Name
WITN. MR.M Lange : Witness' Name
TSTR. HDIL/CN/ZDL/DAL
//GR/CAL : Title Service Mnemonic
TSTG. NA : Title Service Mnemonic
STUS. FINAL : Status
LCNM. Baker Hughes : Logging Company Name
LCC . 150 : Logging Company Code
OPMD. OH.WIRE : Operation Mode
PANA. S.Yassa : Processing Analyst
PCON. Baker Hughes : Processing Contractor
LATI.DEG 0.0000 : Latitude
LONG.DEG 0.0000 : Longitude
~Other information
1 OPERATION IN WELL
HDIL/DAL/ML/ZDL/CN/GR RUN IN COMBINATION
CVOL CALCULATED FOR PROPOSED 5.5" CASING
CALIPER VERIFIED IN CASING
ZDL & CN RUN ON LIMESTONE MATRIX
RHO MATRIX: 2.68 G/CC
HDIL RUN WITH 0.5" STANDOFFS
ABC TO CALCULATED: MUD CONDUCITIVITY
ACOUSTIC POROSITY RUN ON LIMESTONE MATRIX
WELLBORE RUGOSITY WILL AFFECT THE ACCURACY OF MEASUREMENTS
CREW: D.HUTCHISON, K.REED
RIG: DUKE RIG 9
# Curve Data
|