Specific Water Well Detail |
|
|
| Location Info | |||
| Owner: Mick, Norm | Status: Constructed | ||
| Location: T11S, R3W, Sec. 24, NE SE NE | County: Ottawa | ||
| Directions: 871 N 180th | |||
| Latitude: 39.0840919 | Longitude: -97.5945889 | Datum NAD 27 | |
| Latitude: 39.0840913 | Longitude: -97.5948991 | Datum NAD 83 | |
| Longitude and latitude calculated by Survey from township-range-section-quarter calls. Only good to within the quarter call accuracy. | |||
| View well on interactive map | |||
| General Info | ||
| Well Depth: 68.5 ft. | Elevation: ft. | |
| Static Water Level: 25.1 ft. | Est. Yield: 60 gpm. | |
| Comp. Date: 01-Oct-1996 | Well Use: Domestic | |
| DWR Applic. #: | Other ID: | |
| Driller Info | ||
| Driller: Pestinger Pump & Water Well Drlg., Inc. | License #: 388 | |
| Scanned Form | |
| View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. | |
|
Chemical Sample Submitted?: No
Water Well disinfected?: | ||
| Ground water encountered: 25.1 ft. , 0 ft. , 0 ft. | ||
| Pump test data: Well water was 0 ft after 0 hours pumping 0 gpm | ||
| Casing Info | ||
| Casing Type: PVC
Casing Joints: |
Diam: 5 in. to 58.5 ft
Diam: 0 in. to 0 ft Diam: 0 in. to 0 ft | |
| Casing height above land surface: in
Casing Weight: lbs/ft Wall thickness or gauge no.: | ||
| Screen and Perforation Info | ||
| Screen Type: PVC | Screen Openings: Mill slot | |
| Screen-perforated intervals | From: 58.5 ft to 68.5 ft
From: 0 ft to 0 ft From: 0 ft to 0 ft | |
| Gravel pack intervals | From: ft to ft | |
| Grout Info | ||
| Grout used: Bentonite | From: 6 to 26 ft
From: 47 to 59 ft From: 0 to 0 ft | |
| Source of Possible Contamination | ||
| Source: OTHER | ||
| Direction from well: | Distance: 0 ft | |
| Lithologic Log
(Log data entered by KGS.) | ||
| From: 0 ft. to 2 ft. | top soil | |
| From: 2 ft. to 34 ft. | sandstone, reddish brown | |
| From: 34 ft. to 69 ft. | sandstone, tan | |