Specific Water Well Detail | ||
Location Info | |||
Owner: Reed, Merv | Status: Constructed | ||
Location: T11S, R4W, Sec. 14, SE SW SW | County: Ottawa | ||
Directions: From K-106 and Ivy Rd, 1 mi W | |||
Latitude: 39.089639 | Longitude: -97.7385531 | Datum NAD 27 | |
Latitude: 39.0896401 | Longitude: -97.7388682 | Datum NAD 83 | |
Longitude and latitude calculated by Survey from township-range-section-quarter calls. Only good to within the quarter call accuracy. | |||
View well on interactive map |
General Info | ||
Well Depth: 129 ft. | Elevation: ft. | |
Static Water Level: 53 ft. | Est. Yield: 75 gpm. | |
Comp. Date: 11-Sep-1997 | Well Use: Domestic | |
DWR Applic. #: 97-212 | Other ID: |
Driller Info | ||
Driller: Pestinger Pump & Water Well Drlg., Inc. | License #: 388 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: | ||
Ground water encountered: 76 ft. , 0 ft. , 0 ft. | ||
Pump test data: Well water was 0 ft after 0 hours pumping 0 gpm | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: |
Diam: 5 in. to 109 ft
Diam: 0 in. to 0 ft Diam: 0 in. to 0 ft | |
Casing height above land surface: in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Mill slot | |
Screen-perforated intervals | From: 109 ft to 129 ft
From: 0 ft to 0 ft From: 0 ft to 0 ft | |
Gravel pack intervals | From: ft to ft |
Grout Info | ||
Grout used: Bentonite | From: 3 to 24 ft
From: 87 to 90 ft From: 0 to 0 ft |
Source of Possible Contamination | ||
Source: | ||
Direction from well: | Distance: 0 ft |
Lithologic Log
(Log data entered by KGS.) | ||
From: 0 ft. to 1 ft. | top soil | |
From: 1 ft. to 11 ft. | clay, reddish brown | |
From: 11 ft. to 18 ft. | silty clay, tan | |
From: 18 ft. to 68 ft. | fine sandstone, tan | |
From: 68 ft. to 89 ft. | sandstone, brown, soft | |
From: 89 ft. to 130 ft. | sandstone |