Specific Water Well Detail | ||
Location Info | |||
Owner: Heeke, Alfred | Status: Constructed | ||
Location: T26S, R22W, Sec. 14, SW NW NW | County: Ford | ||
Directions: from Spearville: 2.5 mi E, 3 mi S | |||
Latitude: 37.7897152 | Longitude: -99.7038894 | Datum NAD 27 | |
Latitude: 37.7897343 | Longitude: -99.7042924 | Datum NAD 83 | |
Longitude and latitude calculated by Survey from township-range-section-quarter calls. Only good to within the quarter call accuracy. | |||
View well on interactive map |
General Info | ||
Well Depth: 57 ft. | Elevation: ft. | |
Static Water Level: 27 ft. | Est. Yield: 30 gpm. | |
Comp. Date: 30-Aug-1989 | Well Use: Domestic | |
DWR Applic. #: | Other ID: |
Driller Info | ||
Driller: Leo Knoefler Drilling | License #: 130 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: | ||
Ground water encountered: 32 ft. , 0 ft. , 0 ft. | ||
Pump test data: Well water was 35 ft after 8 hours pumping 25 gpm | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: |
Diam: 5 in. to 20 ft
Diam: 0 in. to 0 ft Diam: 0 in. to 0 ft | |
Casing height above land surface: in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Saw cut | |
Screen-perforated intervals | From: 20 ft to 57 ft
From: 0 ft to 0 ft From: 0 ft to 0 ft | |
Gravel pack intervals | From: ft to ft |
Grout Info | ||
Grout used: Cement grout | From: 0 to 20 ft
From: 0 to 0 ft From: 0 to 0 ft |
Source of Possible Contamination | ||
Source: Septic Tank | ||
Direction from well: | Distance: 0 ft |
Lithologic Log
(Log data entered by KGS.) | ||
From: 0 ft. to 32 ft. | topsoil and clay | |
From: 32 ft. to 55 ft. | sandstone | |
From: 55 ft. to 57 ft. | white clay |