Specific Water Well Detail |
|
|
| Location Info | |||
| Owner: Landes, Joe | Status: Constructed | ||
| Location: T23S, R23E, Sec. 7, SE SE NW | County: Linn | ||
| Directions: 2651 Harkness, Blue Mound | |||
| Latitude: 38.0599023 | Longitude: -94.9252957 | Datum NAD 27 | |
| Latitude: 38.0599342 | Longitude: -94.9255411 | Datum NAD 83 | |
| Longitude and latitude calculated by Survey from township-range-section-quarter calls. Only good to within the quarter call accuracy. | |||
| View well on interactive map | |||
| General Info | ||
| Well Depth: 175 ft. | Elevation: ft. | |
| Static Water Level: ft. | Est. Yield: gpm. | |
| Comp. Date: 07-Dec-2001 | Well Use: Heat Pump (Closed Loop/Disposal), Geothermal | |
| DWR Applic. #: | Other ID: | |
| Driller Info | ||
| Driller: Evans Energy Development, Inc. | License #: 561 | |
| Scanned Form | |
| View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. | |
|
Chemical Sample Submitted?:
Water Well disinfected?: | ||
| Casing Info | ||
| Casing Type:
Casing Joints: |
Diam: in. to ft | |
| Casing height above land surface: in
Casing Weight: lbs/ft Wall thickness or gauge no.: | ||
| Screen and Perforation Info | ||
| Screen Type: | Screen Openings: | |
| Screen-perforated intervals | From: ft to ft | |
| Gravel pack intervals | From: ft to ft | |
| Grout Info | ||
| Grout used: | From: to ft | |
| Source of Possible Contamination | ||
| Source: | ||
| Direction from well: | Distance: ft | |
| Lithologic Log
(Log data entered by KGS.) | ||
| From: 0 ft. to 4 ft. | soil and clay | |
| From: 4 ft. to 40 ft. | limestone | |
| From: 40 ft. to 44 ft. | shale | |
| From: 44 ft. to 85 ft. | limestone | |
| From: 85 ft. to 96 ft. | shale | |
| From: 96 ft. to 118 ft. | limestone | |
| From: 118 ft. to 175 ft. | shale | |