Specific Water Well Detail | ||
Location Info | |||
Owner: Peat, Fred | Status: Constructed | ||
Location: T31S, R26W, Sec. 20, NE NW NW | County: Meade | ||
Directions: from Fowler: 2 mi S, 1.25 mi E | |||
Latitude: 37.342399 | Longitude: -100.1787103 | Datum NAD 27 | |
Latitude: 37.3424231 | Longitude: -100.1791289 | Datum NAD 83 | |
Longitude and latitude calculated by Survey from township-range-section-quarter calls. Only good to within the quarter call accuracy. | |||
View well on interactive map |
General Info | ||
Well Depth: 165 ft. | Elevation: ft. | |
Static Water Level: 75 ft. | Est. Yield: 30 gpm. | |
Comp. Date: 20-Jun-1984 | Well Use: Domestic | |
DWR Applic. #: | Other ID: |
Driller Info | ||
Driller: Cornie Friesen Windmill and Supply Co. | License #: 252 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: | ||
Ground water encountered: 0 ft. , 0 ft. , 0 ft. | ||
Pump test data: Well water was 0 ft after 0 hours pumping 0 gpm | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: |
Diam: 5 in. to 105 ft
Diam: 0 in. to 0 ft Diam: 0 in. to 0 ft | |
Casing height above land surface: in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Saw cut | |
Screen-perforated intervals | From: 105 ft to 165 ft
From: 0 ft to 0 ft From: 0 ft to 0 ft | |
Gravel pack intervals | From: ft to ft |
Grout Info | ||
Grout used: Neat cement | From: 4 to 14 ft
From: 0 to 0 ft From: 0 to 0 ft |
Source of Possible Contamination | ||
Source: Sewer lines | ||
Direction from well: | Distance: 0 ft |
Lithologic Log
(Log data entered by KGS.) | ||
From: 0 ft. to 5 ft. | topsoil | |
From: 5 ft. to 90 ft. | sandy clay (lost circulation at 48 feet) | |
From: 90 ft. to 170 ft. | unknown no circulation | |
From: 170 ft. to 172 ft. | yellow clay |