Specific Water Well Detail | ||
Location Info | |||
Owner: Burt, Carry | Status: Constructed | ||
Location: T12S, R2W, Sec. 6, SW NE SW | County: Ottawa | ||
Directions: 610 N Parker, Bennington | |||
Latitude: 39.0350919 | Longitude: -97.5875625 | Datum NAD 27 | |
Latitude: 39.0350918 | Longitude: -97.5878726 | Datum NAD 83 | |
Longitude and latitude calculated by Survey from township-range-section-quarter calls. Only good to within the quarter call accuracy. | |||
View well on interactive map |
General Info | ||
Well Depth: 40 ft. | Elevation: 1250 ft. | |
Static Water Level: 23 ft. | Est. Yield: 15 gpm. | |
Comp. Date: 07-May-1990 | Well Use: Domestic, Lawn and Garden | |
DWR Applic. #: | Other ID: |
Driller Info | ||
Driller: Pestinger Pump & Water Well Drlg., Inc. | License #: 388 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: | ||
Ground water encountered: 23 ft. , 0 ft. , 0 ft. | ||
Pump test data: Well water was 31 ft after 1 hours pumping 10 gpm | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: |
Diam: 5 in. to 30 ft
Diam: 0 in. to 0 ft Diam: 0 in. to 0 ft | |
Casing height above land surface: in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Mill slot | |
Screen-perforated intervals | From: 30 ft to 40 ft
From: 0 ft to 0 ft From: 0 ft to 0 ft | |
Gravel pack intervals | From: ft to ft |
Grout Info | ||
Grout used: Neat cement | From: 0 to 20 ft
From: 0 to 0 ft From: 0 to 0 ft |
Source of Possible Contamination | ||
Source: Lateral lines | ||
Direction from well: | Distance: 0 ft |
Lithologic Log
(Log data entered by KGS.) | ||
From: 0 ft. to 3 ft. | top soil | |
From: 3 ft. to 23 ft. | clay | |
From: 23 ft. to 35 ft. | medium sand | |
From: 35 ft. to 40 ft. | clay | |
From: 40 ft. to ft. | shale |