Specific Water Well Detail |
|
|
| Location Info | |||
| Owner: Mumm, Greg | Status: Constructed | ||
| Location: T2S, R32W, Sec. 30, SW NE NW NW | County: Rawlins | ||
| Directions: 560 Dimmit St, Ludell | |||
| Latitude: 39.8562183 | Longitude: -100.9603685 | Datum NAD 27 | |
| Latitude: 39.856222 | Longitude: -100.960806 | Datum NAD 83 | |
| Longitude and latitude from GPS measurements. | |||
| GPS Latitude: 39.856222 | GPS Longitude: -100.960806 | Datum NAD83 | |
| View well on interactive map | |||
| General Info | ||
| Well Depth: 57 ft. | Elevation: 2786 ft. | |
| Static Water Level: 40 ft. | Est. Yield: 20 gpm. | |
| Comp. Date: 27-Nov-2013 | Well Use: Domestic | |
| DWR Applic. #: | Other ID: | |
| Driller Info | ||
| Driller: Wilcox Well Drilling, LLC | License #: 701 | |
| Scanned Form | |
| View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. | |
|
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
| Ground water encountered: 40 ft. | ||
| Bore hole diameter: 9 inches to 57 ft | ||
| Casing Info | ||
| Casing Type: PVC
Casing Joints: Glued |
Diam: 4 in. to 57 ft | |
| Casing height above land surface: 12 in
Casing Weight: 200 lbs/ft Wall thickness or gauge no.: .214 | ||
| Screen and Perforation Info | ||
| Screen Type: PVC | Screen Openings: Saw cut | |
| Screen-perforated intervals | From: 37 ft to 57 ft | |
| Gravel pack intervals | From: 0 ft to 5 ft
From: 25 ft to 57 ft | |
| Grout Info | ||
| Grout used: Bentonite | From: 5 to 25 ft | |
| Source of Possible Contamination | ||
| Source: Abandoned water well | ||
| Direction from well: W | Distance: 300 ft | |
| Lithologic Log
(Log data entered from KOLAR.) | ||
| From: 0 ft. to 5 ft. | top soil | |
| From: 5 ft. to 42 ft. | sandy clay | |
| From: 42 ft. to 56 ft. | small to medium gravel | |
| From: 56 ft. to 57 ft. | shale | |