Specific Water Well Detail |
|
|
| Location Info | |||
| Owner: Sturdi - Bilt | Status: Constructed | ||
| Location: T23S, R6W, Sec. 33, NW NW NW NW | County: Reno | ||
| Directions: 3909 Stacy Rd, Hutchinson | |||
| Latitude: 38.0128665 | Longitude: -97.9947147 | Datum NAD 27 | |
| Latitude: 38.01288 | Longitude: -97.99505 | Datum NAD 83 | |
| Longitude and latitude from GPS measurements. | |||
| GPS Latitude: 38.01288 | GPS Longitude: -97.99505 | Datum NAD83 | |
| View well on interactive map | |||
| General Info | ||
| Well Depth: 64 ft. | Elevation: 1574 ft. | |
| Static Water Level: 39 ft. | Est. Yield: 50 gpm. | |
| Comp. Date: 13-May-2014 | Well Use: Domestic | |
| DWR Applic. #: | Other ID: | |
| Driller Info | ||
| Driller: Miller Drilling | License #: 447 | |
| Scanned Form | |
| View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. | |
|
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
| Ground water encountered: 39 ft. | ||
| Pump test data: Well water was 41 ft after .25 hours pumping 25 gpm | ||
| Bore hole diameter: 9 inches to 65 ft | ||
| Casing Info | ||
| Casing Type: PVC
Casing Joints: Glued |
Diam: 5 in. to 64 ft | |
| Casing height above land surface: 18 in
Casing Weight: lbs/ft Wall thickness or gauge no.: SDR26 | ||
| Screen and Perforation Info | ||
| Screen Type: PVC | Screen Openings: Saw cut | |
| Screen-perforated intervals | From: 54 ft to 64 ft | |
| Gravel pack intervals | From: 23 ft to 65 ft | |
| Grout Info | ||
| Grout used: Bentonite | From: 3 to 23 ft | |
| Source of Possible Contamination | ||
| Source: | ||
| Direction from well: | Distance: ft | |
| Lithologic Log
(Log data entered from KOLAR.) | ||
| From: 0 ft. to 29 ft. | Br Clay | |
| From: 29 ft. to 34 ft. | F Sand | |
| From: 34 ft. to 65 ft. | F - C Sand | |