Specific Water Well Detail |
|
|
| Location Info | |||
| Owner: TNT Cattle Co | Status: Constructed | ||
| Location: T27S, R37W, Sec. 6, NE NE SW SW | County: Grant | ||
| Directions: 1117 Ulysses Parkway, Ulysses | |||
| Latitude: 37.7249718 | Longitude: -101.4148088 | Datum NAD 27 | |
| Latitude: 37.72499 | Longitude: -101.41526 | Datum NAD 83 | |
| Longitude and latitude from GPS measurements. | |||
| GPS Latitude: 37.72499 | GPS Longitude: -101.41526 | Datum NAD83 | |
| View well on interactive map | |||
| General Info | ||
| Well Depth: 640 ft. | Elevation: 3081 ft. | |
| Static Water Level: 305 ft. | Est. Yield: 35 gpm. | |
| Comp. Date: 29-Sep-2016 | Well Use: Domestic | |
| DWR Applic. #: | Other ID: | |
| Driller Info | ||
| Driller: Steve's Drilling | License #: 888 | |
| Scanned Form | |
| View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. | |
|
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
| Ground water encountered: 305 ft. | ||
| Bore hole diameter: 10 inches to 640 ft | ||
| Casing Info | ||
| Casing Type: PVC
Casing Joints: Clamped |
Diam: 5 in. to 640 ft | |
| Casing height above land surface: 20 in
Casing Weight: lbs/ft Wall thickness or gauge no.: sdr17 | ||
| Screen and Perforation Info | ||
| Screen Type: PVC | Screen Openings: Mill slot | |
| Screen-perforated intervals | From: 400 ft to 420 ft
From: 440 ft to 460 ft From: 540 ft to 640 ft | |
| Gravel pack intervals | From: 24 ft to 640 ft | |
| Grout Info | ||
| Grout used: Bentonite | From: 4 to 24 ft | |
| Source of Possible Contamination | ||
| Source: Sewer lines | ||
| Direction from well: east | Distance: 200 ft | |
| Lithologic Log
(Log data entered from KOLAR.) | ||
| From: 0 ft. to 80 ft. | clay | |
| From: 80 ft. to 120 ft. | medium sand and streaks clay | |
| From: 120 ft. to 160 ft. | clay | |
| From: 160 ft. to 340 ft. | streaks of sand and clay | |
| From: 360 ft. to 640 ft. | sandstone streaks and shale | |