Specific Water Well Detail |
|
|
| Location Info | |||
| Owner: Public Wholesale Water Supply District 17 | Status: Reconstructed | ||
| Location: T24S, R1W, Sec. 6, NW SW SW NW | County: Harvey | ||
| Directions: 3600 S Essex Heights Rd, Halstead | |||
| Latitude: 37.9934874 | Longitude: -97.4815085 | Datum NAD 27 | |
| Latitude: 37.9935 | Longitude: -97.48183 | Datum NAD 83 | |
| Longitude and latitude from GPS measurements. | |||
| GPS Latitude: 37.9935 | GPS Longitude: -97.48183 | Datum NAD83 | |
| View well on interactive map | |||
| General Info | ||
| Well Depth: 144 ft. | Elevation: 1396 ft. | |
| Static Water Level: 29 ft. | Est. Yield: 500 gpm. | |
| Comp. Date: 13-Sep-2016 | Well Use: Public Water Supply | |
| DWR Applic. #: 318113 | Other ID: PH6A | |
| Driller Info | ||
| Driller: Layne Christensen Co. | License #: 102 | |
| Scanned Form | |
| View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. | |
|
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
| Ground water encountered: 29.5 ft. | ||
| Pump test data: Well water was 40.2 ft after 1 hours pumping 450 gpm | ||
| Bore hole diameter: 32 inches to 0 ft | ||
| Casing Info | ||
| Casing Type: Steel
Casing Joints: Welded |
Diam: 10 in. to 94 ft | |
| Casing height above land surface: 18 in
Casing Weight: lbs/ft Wall thickness or gauge no.: .365 | ||
| Screen and Perforation Info | ||
| Screen Type: Stainless steel | Screen Openings: Wire wrapped | |
| Screen-perforated intervals | From: 94 ft to 144 ft | |
| Gravel pack intervals | From: 27 ft to 144 ft | |
| Grout Info | ||
| Grout used: Bentonite | From: 7 to 27 ft | |
| Source of Possible Contamination | ||
| Source: None Known | ||
| Direction from well: 0 | Distance: 0 ft | |