Specific Water Well Detail | ||
Location Info | |||
Owner: Ash Grove Cement Co. | Status: Constructed | ||
Location: T27S, R17E, Sec. 13, NW NE SE SE | County: Neosho | ||
Directions: 1801 N Santa Fe, Chanute | |||
Latitude: 37.6923124 | Longitude: -95.4899096 | Datum NAD 27 | |
Latitude: 37.69236 | Longitude: -95.49017 | Datum NAD 83 | |
Longitude and latitude from GPS measurements. | |||
GPS Latitude: 37.69236 | GPS Longitude: -95.49017 | Datum NAD83 | |
View well on interactive map |
General Info | ||
Well Depth: 50 ft. | Elevation: 920 ft. | |
Static Water Level: 45 ft. | Est. Yield: gpm. | |
Comp. Date: 14-Mar-2018 | Well Use: Monitoring well/observation/piezometer | |
DWR Applic. #: | Other ID: S17PZD-2 |
Driller Info | ||
Driller: unknown | License #: |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: No | ||
Ground water encountered: 45 ft. | ||
Bore hole diameter: 8 inches to 50 ft | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: Threaded |
Diam: 2 in. to 50 ft | |
Casing height above land surface: 30 in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Continuous slot | |
Screen-perforated intervals | From: 40 ft to 50 ft | |
Gravel pack intervals | From: 38 ft to 50 ft |
Grout Info | ||
Grout used: | From: 2 to 34 ft
From: 34 to 38 ft |
Source of Possible Contamination | ||
Source: Landfill | ||
Direction from well: east | Distance: 50 ft |
Lithologic Log
(Log data entered from KOLAR.) | ||
From: 0 ft. to 50 ft. | clay to silty clay |