Specific Water Well Detail | ||
Location Info | |||
Owner: Thieme, Josh | Status: Constructed | ||
Location: T26S, R1W, Sec. 33, SE SE NW NW | County: Sedgwick | ||
Directions: 3604 N Pepper Ridge St, Wichita | |||
Latitude: 37.7492159 | Longitude: -97.4398824 | Datum NAD 27 | |
Latitude: 37.74923 | Longitude: -97.44021 | Datum NAD 83 | |
Longitude and latitude from GPS measurements. | |||
GPS Latitude: 37.74923 | GPS Longitude: -97.44021 | Datum WGS84 | |
View well on interactive map |
General Info | ||
Well Depth: 60 ft. | Elevation: 1344 ft. | |
Static Water Level: 18 ft. | Est. Yield: 18 gpm. | |
Comp. Date: 16-May-2018 | Well Use: Domestic, Lawn and Garden | |
DWR Applic. #: | Other ID: |
Driller Info | ||
Driller: Premier Pump and Well Service, Inc. | License #: 238 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
Ground water encountered: 18 ft. | ||
Bore hole diameter: 11 inches to 60 ft | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: Glued |
Diam: 5 in. to 60 ft | |
Casing height above land surface: 18 in
Casing Weight: lbs/ft Wall thickness or gauge no.: .214 |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Mill slot | |
Screen-perforated intervals | From: 40 ft to 60 ft | |
Gravel pack intervals | From: 21 ft to 60 ft |
Grout Info | ||
Grout used: | From: 1 to 21 ft |
Source of Possible Contamination | ||
Source: Watertight sewer lines | ||
Direction from well: East | Distance: 60 ft |
Lithologic Log
(Log data entered from KOLAR.) | ||
From: 0 ft. to 5 ft. | backfill | |
From: 5 ft. to 10 ft. | brown clay | |
From: 10 ft. to 25 ft. | fine to medium sand | |
From: 25 ft. to 30 ft. | gray clay | |
From: 30 ft. to 60 ft. | fine to medium sand |