Specific Water Well Detail |
|
|
| Location Info | |||
| Owner: Carlson Heating and Air | Status: Constructed | ||
| Location: T4S, R3E, Sec. 28, NE NE SE NE | County: Washington | ||
| Directions: 606 South Elm, Linn | |||
| Latitude: 39.6784712 | Longitude: -97.0878108 | Datum NAD 27 | |
| Latitude: 39.6784741 | Longitude: -97.0881162 | Datum NAD 83 | |
| Longitude and latitude from GPS measurements. | |||
| GPS Latitude: 39.6784741 | GPS Longitude: -97.0881162 | Datum WGS84 | |
| View well on interactive map | |||
| General Info | ||
| Well Depth: 120 ft. | Elevation: 1451 ft. | |
| Static Water Level: 35 ft. | Est. Yield: 20 gpm. | |
| Comp. Date: 05-Dec-2018 | Well Use: Domestic | |
| DWR Applic. #: | Other ID: | |
| Driller Info | ||
| Driller: Flint Hills Drilling | License #: 914 | |
| Scanned Form | |
| View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. | |
|
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
| Ground water encountered: 40 ft. | ||
| Bore hole diameter: 10 inches to 120 ft | ||
| Casing Info | ||
| Casing Type: PVC
Casing Joints: Glued |
Diam: 6 in. to 120 ft | |
| Casing height above land surface: 24 in
Casing Weight: lbs/ft Wall thickness or gauge no.: | ||
| Screen and Perforation Info | ||
| Screen Type: PVC | Screen Openings: Mill slot | |
| Screen-perforated intervals | From: 60 ft to 100 ft | |
| Gravel pack intervals | From: 25 ft to 120 ft | |
| Grout Info | ||
| Grout used: | From: 0 to 25 ft | |
| Source of Possible Contamination | ||
| Source: HOUSE | ||
| Direction from well: NORTH | Distance: 65 ft | |
| Lithologic Log
(Log data entered from KOLAR.) | ||
| From: 0 ft. to 8 ft. | clay | |
| From: 8 ft. to 10 ft. | sandy clay | |
| From: 10 ft. to 65 ft. | weathered sandstone | |
| From: 65 ft. to 80 ft. | sandstone, gray | |
| From: 80 ft. to 120 ft. | gray shale | |