Specific Water Well Detail | ||
Location Info | |||
Owner: Nies Homes Inc. | Status: Constructed | ||
Location: T28S, R3E, Sec. 5, SW SW SW SE | County: Butler | ||
Directions: 2605 E Flint Hills National Parkway, Andover | |||
Latitude: 37.6366456 | Longitude: -97.1248255 | Datum NAD 27 | |
Latitude: 37.636663 | Longitude: -97.125145 | Datum NAD 83 | |
Longitude and latitude from GPS measurements. | |||
GPS Latitude: 37.636663 | GPS Longitude: -97.125145 | Datum NAD83 | |
View well on interactive map |
General Info | ||
Well Depth: 100 ft. | Elevation: 1310 ft. | |
Static Water Level: 32 ft. | Est. Yield: 18 gpm. | |
Comp. Date: 11-Jun-2020 | Well Use: Domestic, Lawn and Garden | |
DWR Applic. #: | Other ID: |
Driller Info | ||
Driller: East Wichita Well & Pump Service LLC | License #: 943 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
Ground water encountered: 32 ft. | ||
Pump test data: Well water was 46 ft after 1 hours pumping 25 gpm | ||
Bore hole diameter: 12 inches to 100 ft | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: Glued |
Diam: 5 in. to 40 ft | |
Casing height above land surface: 12 in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Saw cut | |
Screen-perforated intervals | From: 40 ft to 100 ft | |
Gravel pack intervals | From: 24 ft to 100 ft |
Grout Info | ||
Grout used: | From: 3 to 24 ft |
Source of Possible Contamination | ||
Source: Watertight sewer lines | ||
Direction from well: East | Distance: 20 ft |
Lithologic Log
(Log data entered from KOLAR.) | ||
From: 0 ft. to 30 ft. | clay | |
From: 30 ft. to 80 ft. | shale | |
From: 80 ft. to 100 ft. | limestone |