Specific Water Well Detail |
|
|
| Location Info | |||
| Owner: Williams, Randy | Status: Constructed | ||
| Location: T28S, R1W, Sec. 6, SW SE SW NE | County: Sedgwick | ||
| Directions: 2725 S Lark Lane, Wichita | |||
| Latitude: 37.6436535 | Longitude: -97.4673138 | Datum NAD 27 | |
| Latitude: 37.64367 | Longitude: -97.46764 | Datum NAD 83 | |
| Longitude and latitude from GPS measurements. | |||
| GPS Latitude: 37.64367 | GPS Longitude: -97.46764 | Datum WGS84 | |
| View well on interactive map | |||
| General Info | ||
| Well Depth: 60 ft. | Elevation: 1337 ft. | |
| Static Water Level: 19 ft. | Est. Yield: 20 gpm. | |
| Comp. Date: 04-Jun-2020 | Well Use: Domestic, Lawn and Garden | |
| DWR Applic. #: | Other ID: | |
| Driller Info | ||
| Driller: Weninger Drilling, LLC | License #: 884 | |
| Scanned Form | |
| View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. | |
|
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
| Ground water encountered: 26 ft. | ||
| Bore hole diameter: 10.5 inches to 60 ft | ||
| Casing Info | ||
| Casing Type: PVC
Casing Joints: Glued |
Diam: 5 in. to 60 ft | |
| Casing height above land surface: 16 in
Casing Weight: lbs/ft Wall thickness or gauge no.: | ||
| Screen and Perforation Info | ||
| Screen Type: PVC | Screen Openings: Mill slot | |
| Screen-perforated intervals | From: 30 ft to 60 ft | |
| Gravel pack intervals | From: 25 ft to 60 ft | |
| Grout Info | ||
| Grout used: | From: 3 to 25 ft | |
| Source of Possible Contamination | ||
| Source: Watertight sewer lines | ||
| Direction from well: SW | Distance: 14 ft | |
| Lithologic Log
(Log data entered from KOLAR.) | ||
| From: 0 ft. to 2 ft. | top soil | |
| From: 2 ft. to 26 ft. | clay | |
| From: 26 ft. to 30 ft. | medium sand | |
| From: 30 ft. to 46 ft. | small gravel | |
| From: 46 ft. to 60 ft. | clay | |