Specific Water Well Detail | ||
Location Info | |||
Owner: USD 266 | Status: Constructed | ||
Location: T26S, R1W, Sec. 32, NW SE NE NW | County: Sedgwick | ||
Directions: 3701 N Tyler Rd, Wichita | |||
Latitude: 37.7498176 | Longitude: -97.4550828 | Datum NAD 27 | |
Latitude: 37.74983 | Longitude: -97.45541 | Datum NAD 83 | |
Longitude and latitude from GPS measurements. | |||
GPS Latitude: 37.74983 | GPS Longitude: -97.45541 | Datum WGS84 | |
View well on interactive map |
General Info | ||
Well Depth: 75 ft. | Elevation: 1356 ft. | |
Static Water Level: 18 ft. | Est. Yield: 125 gpm. | |
Comp. Date: 03-Nov-2020 | Well Use: Test Hole, Cased | |
DWR Applic. #: | Other ID: |
Driller Info | ||
Driller: Weninger Drilling, LLC | License #: 884 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
Ground water encountered: 24 ft. | ||
Bore hole diameter: 11.5 inches to 75 ft | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: Glued |
Diam: 6 in. to 75 ft | |
Casing height above land surface: 48 in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Mill slot | |
Screen-perforated intervals | From: 45 ft to 75 ft | |
Gravel pack intervals | From: 29 ft to 75 ft |
Grout Info | ||
Grout used: | From: 3 to 29 ft |
Source of Possible Contamination | ||
Source: Watertight sewer lines | ||
Direction from well: East | Distance: 90 ft |
Lithologic Log
(Log data entered from KOLAR.) | ||
From: 0 ft. to 2 ft. | top soil | |
From: 2 ft. to 22 ft. | clay | |
From: 22 ft. to 24 ft. | fine sand | |
From: 24 ft. to 38 ft. | clay | |
From: 38 ft. to 75 ft. | medium sand and gravel (70/30) |