Specific Water Well Detail |
|
|
| Location Info | |||
| Owner: Carlson HVAC | Status: Constructed | ||
| Location: T7S, R20E, Sec. 12, SW NW NE NE | County: Atchison | ||
| Directions: 2937 Henry Trail Rd, Beloit (five 230-foot bores) | |||
| Latitude: 39.4607492 | Longitude: -95.1275933 | Datum NAD 27 | |
| Latitude: 39.4607482 | Longitude: -95.1278423 | Datum NAD 83 | |
| Longitude and latitude from GPS measurements. | |||
| GPS Latitude: 39.4607482 | GPS Longitude: -95.1278423 | Datum WGS84 | |
| View well on interactive map | |||
| General Info | ||
| Well Depth: 230 ft. | Elevation: 1049 ft. | |
| Static Water Level: ft. | Est. Yield: gpm. | |
| Comp. Date: 23-Apr-2021 | Well Use: Geothermal, Closed Loop, Vertical | |
| DWR Applic. #: | Other ID: | |
| Driller Info | ||
| Driller: Flint Hills Drilling #914 | License #: 914 | |
| Scanned Form | |
| View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. | |
|
Chemical Sample Submitted?: No
Water Well disinfected?: No | ||
| Bore hole diameter: 6 inches to 230 ft | ||
| Casing Info | ||
| Casing Type: HDPE
Casing Joints: Welded |
Diam: .75 in. to 230 ft | |
| Casing height above land surface: 48 in
Casing Weight: lbs/ft Wall thickness or gauge no.: | ||
| Screen and Perforation Info | ||
| Screen Type: None | Screen Openings: None | |
| Screen-perforated intervals | From: ft to ft | |
| Gravel pack intervals | From: ft to ft | |
| Grout Info | ||
| Grout used: | From: 0 to 230 ft | |
| Source of Possible Contamination | ||
| Source: | ||
| Direction from well: | Distance: ft | |
| Lithologic Log
(Log data entered from KOLAR.) | ||
| From: 0 ft. to 27 ft. | clay | |
| From: 27 ft. to 39 ft. | fine and medium sand | |
| From: 39 ft. to 40 ft. | large sand | |
| From: 40 ft. to 43 ft. | weathered limestone | |
| From: 43 ft. to 148 ft. | gray shale | |
| From: 148 ft. to 152 ft. | limestone | |
| From: 152 ft. to 230 ft. | gray shale | |