Specific Water Well Detail |
![]() |
Location Info | |||
Owner: Persinger, Jim | Status: Constructed | ||
Location: T32S, R38W, Sec. 21, NE NW SE SE | County: Stevens | ||
Directions: Rd 7 and Rd T | |||
Latitude: 37.2460327 | Longitude: -101.4501086 | Datum NAD 27 | |
Latitude: 37.246057 | Longitude: -101.450545 | Datum NAD 83 | |
Longitude and latitude from GPS measurements. | |||
GPS Latitude: 37.246057 | GPS Longitude: -101.450545 | Datum WGS84 | |
View well on interactive map |
General Info | ||
Well Depth: 425 ft. | Elevation: ft. | |
Static Water Level: 143 ft. | Est. Yield: 50 gpm. | |
Comp. Date: 20-Jul-2021 | Well Use: Domestic, Livestock | |
DWR Applic. #: | Other ID: |
Driller Info | ||
Driller: SW Windmill & WW Srvc | License #: 805 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
Ground water encountered: 143 ft. | ||
Bore hole diameter: 10 inches to 448 ft | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: Glued |
Diam: 5 in. to 425 ft | |
Casing height above land surface: 24 in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Mill slot | |
Screen-perforated intervals | From: 365 ft to 425 ft | |
Gravel pack intervals | From: 25 ft to 425 ft |
Grout Info | ||
Grout used: | From: 5 to 25 ft |
Source of Possible Contamination | ||
Source: | ||
Direction from well: | Distance: ft |
Lithologic Log
(Log data entered from KOLAR.) | ||
From: 0 ft. to 2 ft. | top soil | |
From: 2 ft. to 60 ft. | clay and sandy clay | |
From: 60 ft. to 92 ft. | clay and sand layers | |
From: 92 ft. to 285 ft. | caliche and sandy clay | |
From: 285 ft. to 340 ft. | coarse and sandy clay | |
From: 340 ft. to 387 ft. | sandy clay | |
From: 387 ft. to 440 ft. | sand | |
From: 440 ft. to 448 ft. | clay |