Specific Water Well Detail | ||
Location Info | |||
Owner: Walton Plumbing | Status: Constructed | ||
Location: T21S, R8W, Sec. 10, SW NW NW SW | County: Rice | ||
Directions: 2060 16th Rd | |||
Latitude: 38.2380585 | Longitude: -98.1965785 | Datum NAD 27 | |
Latitude: 38.23807 | Longitude: -98.19692 | Datum NAD 83 | |
Longitude and latitude from GPS measurements. | |||
GPS Latitude: 38.23807 | GPS Longitude: -98.19692 | Datum NAD83 | |
View well on interactive map |
General Info | ||
Well Depth: 60 ft. | Elevation: ft. | |
Static Water Level: 10 ft. | Est. Yield: 150 gpm. | |
Comp. Date: 08-Feb-2022 | Well Use: Domestic | |
DWR Applic. #: | Other ID: |
Driller Info | ||
Driller: Miller Drilling | License #: 447 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: Yes | ||
Ground water encountered: 11 ft. | ||
Pump test data: Well water was 17 ft after .25 hours pumping 100 gpm | ||
Bore hole diameter: 8.5 inches to 62 ft | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: Glued |
Diam: 5 in. to 60 ft | |
Casing height above land surface: 12 in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Saw cut | |
Screen-perforated intervals | From: 50 ft to 60 ft | |
Gravel pack intervals | From: 18 ft to 62 ft |
Grout Info | ||
Grout used: | From: 3 to 18 ft |
Source of Possible Contamination | ||
Source: Septic Tank | ||
Direction from well: N | Distance: 125 ft |
Lithologic Log
(Log data entered from KOLAR.) | ||
From: 0 ft. to 4 ft. | brown clay | |
From: 4 ft. to 11 ft. | fine-medium sand and clay | |
From: 11 ft. to 62 ft. | sand and gravel |