Specific Water Well Detail | ||
Location Info | |||
Owner: Schlochtermeier, Roy/Sterling Drilling | Status: Constructed | ||
Location: T21S, R11W, Sec. 7, SE SE SE | County: Stafford | ||
Directions: from Hudson: 5 mi E, 9 mi N | |||
Latitude: 38.2326764 | Longitude: -98.5650093 | Datum NAD 27 | |
Latitude: 38.232689 | Longitude: -98.5653651 | Datum NAD 83 | |
Longitude and latitude calculated by Survey from township-range-section-quarter calls. Only good to within the quarter call accuracy. | |||
View well on interactive map |
General Info | ||
Well Depth: 92 ft. | Elevation: ft. | |
Static Water Level: 35 ft. | Est. Yield: 60 gpm. | |
Comp. Date: 31-Aug-1990 | Well Use: Oil Field Water Supply | |
DWR Applic. #: 900388 | Other ID: Schlochtermeier 1-7 |
Links | |
No Wizard information available. | |
View info from WIMAS Water Right Data base... |
Driller Info | ||
Driller: Kelly's Water Well Service, Inc. | License #: 186 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: | ||
Ground water encountered: 35 ft. , 0 ft. , 0 ft. | ||
Pump test data: Well water was 0 ft after 0 hours pumping 0 gpm | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: |
Diam: 5 in. to 72 ft
Diam: 0 in. to 0 ft Diam: 0 in. to 0 ft | |
Casing height above land surface: in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Saw cut | |
Screen-perforated intervals | From: 72 ft to 92 ft
From: 0 ft to 0 ft From: 0 ft to 0 ft | |
Gravel pack intervals | From: ft to ft |
Grout Info | ||
Grout used: Neat cement | From: 0 to 20 ft
From: 0 to 0 ft From: 0 to 0 ft |
Source of Possible Contamination | ||
Source: Oil well/gas well | ||
Direction from well: | Distance: 0 ft |
Lithologic Log
(Log data entered by KGS.) | ||
From: 0 ft. to 45 ft. | clay | |
From: 45 ft. to 92 ft. | sand and gravel |