Specific Water Well Detail |
![]() |
Location Info | |||
Owner: Gabbert and Jones | Status: Plugged | ||
Location: T33S, R38W, Sec. 32, NE SW SE | County: Stevens | ||
Directions: from Feterita, 2 mi S, 1 mi E, and 0.25 mi N | |||
Latitude: 37.1291735 | Longitude: -101.4706997 | Datum NAD 27 | |
Latitude: 37.1291992 | Longitude: -101.4711365 | Datum NAD 83 | |
Longitude and latitude calculated by Survey from township-range-section-quarter calls. Only good to within the quarter call accuracy. | |||
View well on interactive map |
General Info | ||
Well Depth: 400 ft. | Elevation: ft. | |
Static Water Level: 157 ft. | Est. Yield: gpm. | |
Comp. Date: 05-Oct-1987 | Well Use: Oil Field Water Supply | |
DWR Applic. #: T87-369 | Other ID: Olson A-1 |
Driller Info | ||
Driller: T & W Water Well Serv., Inc. | License #: 142 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Casing Info | ||
Casing Type: PVC
Diam: 5 in. Casing height above land surface: in |
Grout Info | ||
Grout used: Cement grout | From: 147 to 137 ft
From: 23 to 3 ft From: 0 to 0 ft |
Source of Possible Contamination | ||
Source: Oil well/gas well | ||
Direction from well: | Distance: 0 ft |