Specific Water Well Detail | ||
Location Info | |||
Owner: Council, Dewey, Jr. | Status: Constructed | ||
Location: T11S, R37W, Sec. 13, SW NW SW | County: Logan | ||
Directions: from Winona: 6 mi W, 2 mi N, 2 mi W, .5 mi N | |||
Latitude: 39.097419 | Longitude: -101.3844769 | Datum NAD 27 | |
Latitude: 39.0974258 | Longitude: -101.3849169 | Datum NAD 83 | |
Longitude and latitude calculated by Survey from township-range-section-quarter calls. Only good to within the quarter call accuracy. | |||
View well on interactive map |
General Info | ||
Well Depth: 55 ft. | Elevation: ft. | |
Static Water Level: 21 ft. | Est. Yield: gpm. | |
Comp. Date: 02-Sep-1993 | Well Use: Domestic | |
DWR Applic. #: | Other ID: |
Driller Info | ||
Driller: Bartell Drilling & Machine Works | License #: 139 |
Scanned Form | |
View scan of this form in PDF format. | |
You will need the Acrobat PDF Reader, available free from Adobe, to read this file. |
Chemical Sample Submitted?: No
Water Well disinfected?: | ||
Ground water encountered: 0 ft. , 0 ft. , 0 ft. | ||
Pump test data: Well water was 0 ft after 0 hours pumping 0 gpm | ||
Casing Info | ||
Casing Type: PVC
Casing Joints: |
Diam: 5 in. to 45 ft
Diam: 0 in. to 0 ft Diam: 0 in. to 0 ft | |
Casing height above land surface: in
Casing Weight: lbs/ft Wall thickness or gauge no.: |
Screen and Perforation Info | ||
Screen Type: PVC | Screen Openings: Saw cut | |
Screen-perforated intervals | From: 45 ft to 55 ft
From: 0 ft to 0 ft From: 0 ft to 0 ft | |
Gravel pack intervals | From: ft to ft |
Grout Info | ||
Grout used: Neat cement | From: 4 to 18 ft
From: 0 to 0 ft From: 0 to 0 ft |
Source of Possible Contamination | ||
Source: OTHER | ||
Direction from well: | Distance: 0 ft |
Lithologic Log
(Log data entered by KGS.) | ||
From: 0 ft. to 8 ft. | Topsoil | |
From: 8 ft. to 20 ft. | Sandy clay | |
From: 20 ft. to 52 ft. | Sand and clay strips | |
From: 52 ft. to 55 ft. | Ochre and shale |